• 제목/요약/키워드: thermal losses

검색결과 244건 처리시간 0.027초

Prediction of the Vase Life of Cut Lily Flowers Using Thermography

  • Lee, Ja Hee;Choi, So Young;Park, Hye Min;Oh, Sang Im;Lee, Ae Kyung
    • 인간식물환경학회지
    • /
    • 제22권3호
    • /
    • pp.233-239
    • /
    • 2019
  • This study was conducted in order to predict the vase life of cut lily 'Woori Tower' flowers using a non-destructive thermal imaging technique. It was found that the temperature of cut lily flowers was maintained at 20℃ and was slightly lower than the air temperature until they bloomed. On the 11th day, when flowers bloomed, the temperature of leaves and flowers was measured to be 18.75±0.38℃ and 19.23±0.32℃ respectively, and their difference with ambient temperature was over 3℃. The flower temperature increased slightly when the vase life of cut lily flowers ended, and the temperature difference between the air and leaf temperature (1.77℃) and between the air and flower temperature (1.39℃) got smaller. No visible aging symptom was observed, but it was found that the temperature had risen due to water losses and less functional stomata. The vase life of cut lily flowers can be predicted based on changes in temperature and it will be also possible to predict the potential quality and vase life of cut flowers before harvesting them in greenhouses.

생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구 (Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems)

  • 김윤기;고재균
    • 한국농공학회지
    • /
    • 제22권1호
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

열 이온화 질량분석기를 이용한 Ru 동위원소 측정 및 동중원소 영향 보정 (The isobaric effect correction and measurement of the Ru isotopes by thermal ionization mass spectrometry)

  • 전영신;김정석;한선호;송규석
    • 분석과학
    • /
    • 제23권5호
    • /
    • pp.498-504
    • /
    • 2010
  • 열 이온화 질량분석을 이용한 루테늄(Ru) 동위원소 비 측정은 루테늄의 이온화 포텐셜이 높고 산화상태로 휘발이 일어나 시료가 쉽게 소모되어 안정된 이온피크를 얻기가 어렵다. 따라서 이온화 효율을 높이고 안정적 이온생성을 위한 실험과 질량분석에 사용되는 레늄(Re) 필라멘트에 함유된 불순물들에 의한 동중원소 영향을 검토하였다. 질량분석에서 double filament를 사용하는 것 보다는 single filament를 사용하는 것이 더 안정적 이온 피크를 얻을 수 있었을 뿐만 아니라 몰리브데넘(Mo)에 의한 동중원소 영향도 작았다. 또한 필라멘트 온도를 필요이상 높이면 높일수록 동중원소 영향이 큼을 알 수 있었다. 즉, 불순물로 함유된 Mo이 Ru 동위원소 비 측정에 큰 영향을 주었다. 특히 필라멘트 온도를 일정한 시간 간격을 두고 서서히 올려주는 것이 안정된 피크를 얻는데 매우 중요함을 알 수 있었다. Mo으로부터 오는 동중원소 영향을 $^{94}Mo/^{99}Ru$ 비를 측정하여 보정함으로써 Ru 동위원소 비를 정확히 측정할 수 있었다.

마할라노비스 거리를 이용한 증기보일러 튜브의 고장탐지방법 (Fault Detection Method for Steam Boiler Tube Using Mahalanobis Distance)

  • 유정원;장재열;유재영;김성신
    • 한국지능시스템학회논문지
    • /
    • 제26권3호
    • /
    • pp.246-252
    • /
    • 2016
  • 화력발전소의 설비들은 매우 높은 온도와 압력의 환경에서 운전되므로, 설비고장은 상당한 인적 물적 손실로 이어진다. 그러므로 발전설비의 비정상정인 동작 상태를 사전에 확인할 수 있는 고장탐지 시스템이 필수적이다. 본 연구에서는, 화력발전소 증기보일러의 고장탐지를 위해서 마할라노비스 거리(Mahalanobis distance, MD)를 이용하였다. MD 기반의 고장탐지방법에서는, 비정상샘플은 정상샘플들로부터 멀리 떨어져 있다고 가정한다. 정상상태로 동작중인 대상시스템으로부터 수집된 다변량 샘플을 이용하여 평균벡터와 공분산행렬을 계산하고, MD값의 문턱값을 설정한다. 검증단계에서는, 평균벡터와 검증샘플들 간의 MD를 구한 후, 계산된 MD 값이 미리 설정된 문턱값보다 높으면 알람신호가 발생하게 된다. MD 기반의 고장탐지방법의 성능을 검증하기 위해서, 200MW 유연탄 화력발전소의 증기보일러 튜브누설로 인해서 발전정지 된 사례를 사용하였다. 실험결과는 MD 기반의 고장탐지기법이 발전정지가 발생하기 이전의 이상징후를 성공적으로 탐지할 수 있음을 보여준다.

SnBiAg 전도성 페이스트를 이용한 Shingled 결정질 태양광 모듈의 전기적 특성 분석 (Electrical Characteristics of c-Si Shingled Photovoltaic Module Using Conductive Paste based on SnBiAg)

  • 윤희상;송형준;강민구;조현수;고석환;주영철;장효식;강기환
    • 한국재료학회지
    • /
    • 제28권9호
    • /
    • pp.528-533
    • /
    • 2018
  • In recent years, solar cells based on crystalline silicon(c-Si) have accounted for much of the photovoltaic industry. The recent studies have focused on fabricating c-Si solar modules with low cost and improved efficiency. Among many suggested methods, a photovoltaic module with a shingled structure that is connected to a small cut cell in series is a recent strong candidate for low-cost, high efficiency energy harvesting systems. The shingled structure increases the efficiency compared to the module with 6 inch full cells by minimizing optical and electrical losses. In this study, we propoese a new Conductive Paste (CP) to interconnect cells in a shingled module and compare it with the Electrical Conductive Adhesives (ECA) in the conventional module. Since the CP consists of a compound of tin and bismuth, the module is more economical than the module with ECA, which contains silver. Moreover, the melting point of CP is below $150^{\circ}C$, so the cells can be integrated with decreased thermal-mechanical stress. The output of the shingled PV module connected by CP is the same as that of the module with ECA. In addition, electroluminescence (EL) analysis indicates that the introduction of CP does not provoke additional cracks. Furthermore, the CP soldering connects cells without increasing ohmic losses. Thus, this study confirms that interconnection with CP can integrate cells with reduced cost in shingled c-Si PV modules.

국내발전소 소방안전경영시스템구축을 위한 실태평가에 관한 연구 (Evaluation of the Actual Conditions for the Construction of a Firefighting Safety Management System in Domestic Power Plants)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.89-98
    • /
    • 2018
  • 2015년 베이징 화력발전소 화재사고나 2012년 보령화력과 2016년 태안화력 등 국내 발전소 화재사고, 2011년 후쿠시마 원전참사나 2001년 캘리포니아 대정전은 전력관련 소방안전사고로 국민의 안정적 생활과 국가적인 손실을 가져온 사례로 손꼽고 있다. 전기는 국민생활과 경제에 미치는 영향이 절대적이라 위험성이 높은 대용량의 석탄, 가스 및 원자력 등을 연료로 사용하여 전력을 생산하는 발전소가 안전관리의 소홀로 인한 화재폭발사고나 방사능누출, 지진 등 자연재해로 인한 문제가 생길 경우 국민의 생명보호와 재산손실에 직접적 피해뿐만 아니라 경제성장에 미치는 심각한 상황을 우리는 충분히 예상할 수 있다. 본 연구에서는 한국남부발전 등 5개 발전사 및 한수원 소방안전담당자를 대상으로 발전소 소방안전경영시스템 구축의 필요성에 대한 실태조사를 통해 소방전담조직 보강과 전문역량강화 프로그램 운영, 체계적인 소방안전관리를 위한 발전소 맞춤형 소방안전경영시스템의 개발, 최근 이슈가 된 지진에 대비한 내진 대응체계 강화를 개선방안으로 도출하였다.

고속·저토크용 표면부착형 영구자석 동기 전동기의 운전 안정성 확보를 위한 손실 및 열전달 특성 분석 (Loss and Heat Transfer Analysis for Reliability in High Speed and Low Torque Surface Mounted PM Synchronous Motors)

  • 최문석;엄석기
    • 대한기계학회논문집B
    • /
    • 제38권3호
    • /
    • pp.243-254
    • /
    • 2014
  • 고속 저토크 표면 부착 영구자석형 동기 전동기의 운전 안정성 확보를 위하여 과속도 및 과부하 영역에서 전동기 코일 온도 예측이 필수적이다. 0.35mm 의 S18, S08 등급인 35PN440, 35PN220 그리고 0.15mm 의 저손실 재료인 15HTH1000 으로 제작된 고정자 철심을 포함하는 전동기의 정격 구동 조건에서 손실 및 코일 온도를 측정하여 과속도 및 과부하 영역의 손실 및 열저항을 예측하고 열전달 모델링을 수행하였다. 이의 검증을 위하여 무부하 과속도 영역에서 계산된 코일 온도와 실험값을 비교하여 6.4%이하로 일치하였다. 35PN440 을 적용한 전동기에 비하여 15HTH100 을 적용한 전동기는 무차원 회전속도 0.9, 부하율 3.0 일 때 철손실이 84.4% 로 감소하였고, 무차원 코일 온도 1.0 을 기준으로 출력이 85.2% 향상되었다. 정격 구동 영역의 손실 측정 및 열전달 모델링으로 과부하 및 과속도 영역에서 철심재질에 따른 코일 온도 변화 및 전동기 출력 개선량을 정확하게 예측할 수 있음을 알 수 있다.

Finite Element Prediction of Temperature Distribution in a Solar Grain Dryer

  • Uluko, H.;Mailutha, J.T.;Kanali, C.L.;Shitanda, D.;Murase, H
    • Agricultural and Biosystems Engineering
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2006
  • A need exists to monitor and control the localized high temperatures often experienced in solar grain dryers, which result in grain cracking, reduced germination and loss of cooking quality. A verified finite element model would be a useful to monitor and control the drying process. This study examined the feasibility of the finite element method (FEM) to predict temperature distribution in solar grain dryers. To achieve this, an indirect solar grain dryer system was developed. It consisted of a solar collector, plenum and drying chambers, and an electric fan. The system was used to acquire the necessary input and output data for the finite element model. The input data comprised ambient and plenum chamber temperatures, prevailing wind velocities, thermal conductivities of air, grain and dryer wall, and node locations in the xy-plane. The outputs were temperature at the different nodes, and these were compared with measured values. The ${\pm}5%$ residual error interval employed in the analysis yielded an overall prediction performance level of 83.3% for temperature distribution in the dryer. Satisfactory prediction levels were also attained for the lateral (61.5-96.2%) and vertical (73.1-92.3%) directions of grain drying. These results demonstrate that it is feasible to use a two-dimensional (2-D) finite element model to predict temperature distribution in a grain solar dryer. Consequently, the method offers considerable advantage over experimental approaches as it reduces time requirements and the need for expensive measuring equipment, and it also yields relatively accurate results.

  • PDF

에어컨 화재사례 분석 및 예방대책에 관한 연구 (A Study on the Fire Case Analysis of Air Conditioner and Preventive Measures)

  • 김동욱;이기연;김동우;길형준;방선배;정영식
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.40-45
    • /
    • 2013
  • 전기화재는 다양한 원인에 의해 발생하고 있으며 최근에는 복합적인 원인에 의해 발생하기 때문에 전기적, 열적, 기계적, 환경적 영향에 의한 제품의 열화특성과 발열 메커니즘 등 체계적인 연구와 분석을 통한 과학적이고 합리적인 안전설계애안 제시를 위한 연구가 절실히 요구되고 있는 실정이다. 재해로 인한 인적 물적 손실은 국가와 기업의 대외 신뢰도 하락을 가져오고 있으며 제품 안전에 대한 수요는 무한 경쟁에 따른 규제완화의 이유로 증가하고 있다. 기업의 이미지를 증진시키고 국제적 경쟁력을 강화시키기 위해 제품에 대한 안전 설계는 반드시 필요하다. 본 논문에서는 사용량이 점차 증가하고 있는 에어컨에서 전기화재가 발생한 사례와 원인 및 재현실험을 통해 안전설계에 대한 제시를 위해 수행 하였으며 화재 예방대책 등의 기초 자료로 할용 가능할 것으로 기대한다.

폴리히드라존계 킬레이트 고분자의 합성과 특성 (Synthesis and Characterization of Chelated Polymers of Polyhydrazones)

  • 김공수;이영우;이두희
    • 대한화학회지
    • /
    • 제29권5호
    • /
    • pp.543-551
    • /
    • 1985
  • $p^-$, $m^-$, o-phthalaldehyde 및 5,5'-methylene-bis-salicyl aldehyde (PPTA, MPTA, OPTA, MBSA)와 5,5'-methylene-bis-salicylic dihydrazide, terephthalic dihydrazide 및 sebacic dihydrazide(MBSDH, TDH 및 SDH)등의 디히드라지드 화합물을 DMF-$CH_3COOH$ 혼합용액 중에서 축합반응으로 몇가지 새로운 폴리히드라존을 합성하였다. 합성한 폴리히드라존과 그의 금속킬레이트의 용해성, 흡수스펙트라 및 열적성질에 대하여 검토하였다. OPTA와 MBSDH의 반응으로 얻어진 폴리히드라존을 제외한 폴리히드라존과 그의 금속킬레이트는 일반적으로 보통 유기용매에 불응성이었다. 폴리히드라존의 중량열분석 결과 250-350$^{\circ}$C 사이에서 10%의 중량감소가 일어났고 500$^{\circ}$C고 500 폴리히드라존의 중량열분석 결과 250~350$^{\circ}$C 사이에서 10%의 중량감소가 일어났고 500$^{\circ}$C에서 32.5~63.5% 범위의 잔유중량을 나타내었다. 합성한 폴리히드라존 중에서 PPTA-MBSDH(IIa)및 MBSA-MBSDH(IIIa)가 열분해온도가 비교적 높았으며 IIa의 금속킬레이트에 있어서는 Zn(II)-IIa>Ni(II)-IIa>Co(II)-IIa>Cu(II)-IIa의 순서로 열분해온도가 저하되었다.

  • PDF