• 제목/요약/키워드: thermal losses

검색결과 245건 처리시간 0.027초

Loss Analysis and Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbine Systems

  • Lee, Kihyun;Suh, Yongsug;Kang, Yongcheol
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1380-1391
    • /
    • 2015
  • This paper provides a loss analysis and comparison of high power semiconductor devices in 5MW Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbine Systems (WTSs). High power semiconductor devices of the press-pack type IGCT, module type IGBT, press-pack type IGBT, and press-pack type IEGT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on the back-to-back type 3-level Neutral Point Clamped Voltage Source Converters (3L-NPC VSCs) supplied from a grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through a loss analysis considering both the conduction and switching losses under the operating conditions of 5MW PMSG wind turbines, particularly for application in offshore wind farms. This paper investigates the loss analysis and thermal performance of 5MW 3L-NPC wind power inverters under the operating conditions of various power factors. The loss analysis and thermal analysis are confirmed through PLECS Blockset simulations with Matlab Simulink. The comparison results show that the press-pack type IGCT has the highest efficiency including the snubber loss factor.

유한요소법을 이용한 IH-JAR의 열확산 예측에 관한 연구 (A Study on the Heat-Diffusion Prediction of Induction Heating JAR using Finite Element Method)

  • 오홍석
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.8-13
    • /
    • 2002
  • 유도가열 기술은 담금질, 단조를 위한 예열, 용융 그리고 요리 등과 같은 산업 전반에 걸쳐서 아주 폭넓게 사용되는 기술이다. 본 논문에서는 IH-JAR의 효과적인 설계를 위하여 자계 및 열 해석을 하였다. IH-lAR의 내부자계는 3차원 축대칭 유한요소법을 사용하여 해석하였으며, 열원은 IH-JAR 내부에서 유도된 와전류에 의하여 발생되고, 열은 열원과 열방정식을 사용하여 계산되어진다. 또한, IH-JAR의 온도분포를 시간과 투자율에 따라 제시하였다.

FEM을 이용한 24MVA 몰드변압기의 Hot-spot 위치 분석 연구 (Analysis on the Hot-spot Temperature Location of a 24MVA Cast Resin Transformer by FEM)

  • 김영배;하정우;신판석
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.26-32
    • /
    • 2012
  • This paper calculates the core and copper losses as heating sources of a 24MVA cast resin transformer, and analyzes the thermal distribution of the transformer to find out its hot-spot area by FEM program. Since the winding of the transformer is composed with many series and parallel circuits, the analyzing model of the winding is simplified and modelled by axi-symmetric domain. As the results, the maximum temperature is estimated by $137^{\circ}C$ in the upper part of the low-voltage winding. The maximum temperature has discrepancy of approximately $10^{\circ}C$, which is able to be considered as an acceptable error range in the design stage of power transformers. For the overall pattern of the temperature distribution is almost same as test results, the analyzing method can be a useful tool to find out a hot-spot area of the winding.

고온 연료전지 발전단지의 내부계통 고장에 의한 운전환경에 대한 분석 (A Study on the Operation Condition by Electrical Fault in the High Temperature Fuel Cell Plant)

  • 정영환;채희석;김재철;조성민
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.51-59
    • /
    • 2013
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack, increases in the power output of high temperature fuel cell typically must be made at a slow rate. So, the short time interruption of high temperature fuel cell causes considerable generated energy losses. Because of the characteristic of high temperature fuel cell, we analyzed the impact of electrical fault in the fuel cell plant on other fuel cell generators in the same plant site. A various grounding configuration and voltage sag are analyzed. Finally, we presented the solution to minimize the effect of fault on other fuel cell generators.

패각 폐기물을 이용한 $H_2S$ 제거에 관한 연구(I) -열중량분석기를 이용한 황화반응특성- (A Study on the $H_2S$ Removal with Utilization of Seashell Waste(I) -The Characteristics of Sulfided Reaction Using Thermal Gravimetric Analyzer-)

  • 김영식
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.45-49
    • /
    • 2003
  • In this study, lots of methods have been studing to utilize energy and decrease contaminated effluents. There has been great progress on IGCC (Integrated gasification combined cycle) to reduce thermal energy losses. The following results have been conducted from desulfurization experiments using waste shell to remove H$_2$S. According to TGA results, temperature had influenced on H$_2$S removal efficiency. As desulfurization temperature increased, desulfurization efficiency increased. Also, maximum desulfurization efficiency was observed at 80$0^{\circ}C$. Desulfurization was related to calcination temperature. Considering temperature ranges of exhausted gas from hot gas gasification equipment were 400~80$0^{\circ}C$. Thus, desulfurization efficiency would be increased desulfurization temperature situation at highly. Experiments by TGA showed that particle size of sorbents had influenced on desulfurization capacity. Maximum desulfurization capacity was observed at 0.631 mm for oyster and clam. Rest of sorbents showed similar capacity within 0.171~0.335 mm particle size range. So, particle size would be considered. When would be used waste shells as IGCC sorbents. According to the results about desulfurization capacity by TGA, oyster had the best desulfurization capacity among limestone and waste shell. We would be identify to substituted oyster for existing sorbents

Development and Performance Investigation on a 60kW Induction Motor for EV Propulsion

  • Chun, Yon-Do;Park, Byoung-Gun;Kim, Dong-Jun;Choi, Jae-Hak;Han, Pil-Wan;Um, Sukkee
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.639-643
    • /
    • 2016
  • This paper introduces the development process and investigation of a 60kW induction motor for electric vehicles. We present performance improvement in the induction motor of electric vehicle using copper die-casting based on a multi-gate process. Copper die-casting motors can reduce the size of the motor, the loss of the rotor, and material costs. We also introduce electromagnetic, thermal, mechanical design and analysis results that satisfy the design and the performance requirements. In order to analyze losses accurately of induction motor, commercial finite element analysis is done considering PWM voltage and thermal characteristics by using lumped-circuit parameters. Experimental tests are also carried out to validate the traction motor design.

도금액의 내부 유입 방지를 위한 래버린스 시일 설계 (Labyrinth Seal Design for Preventing Internal Inflow of Plating Solution)

  • 이덕규;김완두
    • Tribology and Lubricants
    • /
    • 제33권6호
    • /
    • pp.256-262
    • /
    • 2017
  • Molten zinc plating is a process in which zinc is thinly coated over a metallic or non-metallic surface. It is used in various industrial fields for corrosion resistance and decoration. During the process, a steel sheet is passed through a roll that rotates inside the molten zinc liquid in the temperature range of $460^{\circ}C$ to $680^{\circ}C$, and the plating liquid flows into the roll causing abrasion and erosion of the roll surface. This problem is known to accelerate the replacement cycle of the roll and cause considerable economic loss owing to production line stoppage. Here, we propose a mechanism that operates at high temperature and pressure with a labyrinth type seal design to resolve this problem. We theoretically investigate the flow of the plating solution inside the seal and compute the minimum rotation speed required to prevent the plating solution from entering the seal chamber. In addition, we calculate the thermal deformation of the seal during operation and display thermally deformed dimensions at high temperatures. To verify the theoretical results, we perform experiments using pilot test equipment working in the actual plating environment. The experimental results are in good agreement with theoretical results. We expect our results to contribute towards the extension of the roll's life span and thereby reduce the economic losses.

GaN MOSFET을 이용한 고밀도, 고효율 48V 버스용 3-출력 Buck Converter 설계 (A High Efficiency, High Power-Density GaN-based Triple-Output 48V Buck Converter Design)

  • 이상민;이승환
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a 70 W buck converter using GaN metal-oxide-semiconductor field-effect transistor (MOSFET) is developed. This converter exhibits over 97 % efficiency, high power density, and 48 V-to-12 V/1.2 V/1 V (triple output). Three gate drivers and six GaN MOSFETs are placed in a 1 ㎠ area to enhance power density and heat dissipation capacity. The theoretical switching and conduction losses of the GaN MOSFETs are calculated. Inductances, capacitances, and resistances for the output filters of the three buck converters are determined to achieve the desired current, voltage ripples, and efficiency. An equivalent circuit model for the thermal analysis of the proposed triple-output buck converter is presented. The junction temperatures of the GaN MOSFETs are estimated using the thermal model. Circuit operation and temperature analysis are evaluated using a circuit simulation tool and the finite element analysis results. An experimental test bed is built to evaluate the proposed design. The estimated switch and heat sink temperatures coincide well with the measured results. The designed buck converter has 130 W/in3 power density and 97.6 % efficiency.

Texture, Morphology and Photovoltaic Characteristics of Nanoporous F:SnO2 Films

  • Han, Deok-Woo;Heo, Jong-Hyun;Kwak, Dong-Joo;Han, Chi-Hwan;Sung, Youl-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.93-97
    • /
    • 2009
  • The nanoporous $F:SnO_2$ materials have been prepared through the controlled hydrolysis of fluoro(2-methylbutan-2-oxy)di(pentan-2,4-dionato)tin followed by thermal treatment at $400-550^{\circ}C$. The main IR features include resonances at 660, 620 and 540 cm-1. From the TG-DTG result, three main mass losses of 6.5, 13.3 and 3.8 at 81, 289 and $490^{\circ}C$ are observed between 50 and $650^{\circ}C$ yielding a final residue of 76.0%. The size of Sn $O_2$ nanoparticles rose from 5 nm to 10-12 nm as the temperature of thermal treatment is increased from 400 to $550^{\circ}C$.

유한요소법에 의한 IH-Cooker의 열해석에 관한 연구 (A Study on the Thermal Analysis of Induction Hooting Cooker with Finite Element Method)

  • 오홍석
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.80-85
    • /
    • 2003
  • 본 논문에서는 유도가열조리기의 효과적인 설계를 위하여 입력주파수 변화에 따른 유도가열조리기의 자계와 열계 해석 방법을 제시하였다. 유도가열조리기의 내부자계는 3차원 축대칭 유한요소법을 사용하여 해석하였으며, 열원은 유도가열조리기의 내부에서 유도된 와전류에 의하여 발생되고, 열은 열원과 열방정식을 사용하여 계산되어진다. 또한, 유도가열조리기의 온도특성을 스테인레스와 알루미늄 각각에 대하여 주파수와 투자율에 따라 제시하였다.