• Title/Summary/Keyword: thermal insulation of clothing

검색결과 98건 처리시간 0.032초

투습발수직물과 보온단열소재의 열 및 수분전달 특성 (Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials)

  • 조길수;최종명;이정주;이선우
    • 한국의류학회지
    • /
    • 제16권2호
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

저온창고 작업자의 열적 쾌적성 증진을 위한 유니폼 조사 연구 - 대형 할인 마트 종사자를 대상으로 - (Research for Development of Thermal Comfort Uniforms of Workers on a Low Temperature Storage)

  • 유화숙
    • 한국의류산업학회지
    • /
    • 제12권4호
    • /
    • pp.513-522
    • /
    • 2010
  • The aim of this study is to investigate the actual state for the development of the thermally comfortable uniform for workers on a low temperature storage. Observation, interview and survey were executed focusing on the environment, clothing, and human factors which have effects on the comfort of workers. Of 400 distributed, 253 questionnaires were analyzed through descriptives, frequency, ANOVA, t-test, multi-response analysis, correlation analysis with SPSS 12.0. The results are following. Coming and going between a selling area and cold storages, the workers showed to experience a big temperature gap. They indicated to feel cold on face and hands which were not covered by clothing and have got sick because of low temperature. The workers wanted the uniform made of functional fabrics, especially heat insulation fabrics. Female workers rather than male workers, the older, and the longer their working period were, the more uncomfortable they revealed to feel. The workers who works on the daily products part or mainly on the freezer appeared to feel cold more than any other workers. In conclusion, it was found that the uniform which consider steady state and unsteady state heat transfer together must be developed.

시판 한복지의 열.수분이동 특성 (Heat ,rind Moisture Transfer Properties of Fabrics for Korean Folk Clothes)

  • 성수광;성은정
    • 한국의류학회지
    • /
    • 제20권6호
    • /
    • pp.1071-1083
    • /
    • 1996
  • This study was carried out to obtain some fundamental data for designing thermally comfortable Korean folk clothes (KFC) which were classified into 4 groups according to seasons and materials. It was conducted to find the relationship among structural, thermal, and moisture transfer properties, and then the properties of heat and mositure transfer while changing thickness of air layer of selected similar fabrics with various thickness were examined. The summarized results of this study were as follows ; 1. The relationship between the structrual and thermal properties showed high positive correlation with thickness SE thermal insulation value (TIV), porosity & TIV. 2. The relationship between the structural and mositure transfer properties showed high negative correlation with thickness & moisture vapor permeability (Mp), porosity & Mp respectively. 3. The relationship between the heat and moisture transfer properites showed high negative correlation with qmax, air permeability (Ap), Mp & TIV while showed high positive with Ap & Mp respectively. 4. Resistance to dry heat transfer according to thickness of air layer for KFC was increassed rapidly up to 2 mm and above this increasing rate was reduced. Resistance to evaporative heat transfer was remarkable changes in 6∼8 mm but slowly in 6∼8 man. 5. Mioisture permeability index (i) according to thickness of air layer for KFC showed the greatest value at 2 mm but had not difference between groups according to thickness.

  • PDF

신축성에 따른 여고생 교복의 착용감에 관한 연구(제1보) -역학적 특성과 보온성에 관하여- (A Study on Wearing Sensations of Girls'High School Uniforms Based on Elasticity(1) -Focusing on Mechanical Properties and Insulation-)

  • 민경혜;류덕환
    • 한국의류학회지
    • /
    • 제27권5호
    • /
    • pp.545-553
    • /
    • 2003
  • A good school uniform leads students to good behavior and have them enjoy desirable school life. Therefore a better fabric for girls' high school uniform suggested through two series of studies; first, examined the various aspects of current uniforms. Second, made a new fabric for uniform considering elasticity for activity and comfortableness, and compared its characteristics with those of the current uniforms. The results are as follows; 1 Most of students wanted uniforms considering elasticity for activity and wearing. 2. The measurement of the elasticities of the uniform materials showed that the material which was made using the elastic material was more elastic than the currently used material by 42.12% in summer material and 20.05% in winter one. 3. The analysis using the combination of the values of mechanical properties showed that the elastic material was better in the wearing, tactile senses, and drape properties than the current material, even though it was a little worse in shape-stability. 4. To compare the thermal insulation, clo values were measured. For winter uniform, the elastic material was better than the current one in keeping warm. However, This study did not find any big difference between summer uniform materials.

'발열내복'이라 광고되는 시판 기능성 보온내복의 써멀 마네킹과 인체 착용 실험을 통한 체온조절 성능 평가 (Evaluation of Thermoregulatory Properties of Thermal Underwear Named as 'Heating Underwear' using Thermal Manikin and Human Performance Test)

  • 이효현;이영란;김지은;김시연;이주영
    • 한국의류산업학회지
    • /
    • 제17권4호
    • /
    • pp.657-665
    • /
    • 2015
  • This study evaluated the thermoregulatory properties of functional thermal underwear ('heating underwear') in markets using a thermal manikin and human wear trials. One ordinary thermal underwear (ORD) and two functional thermal underwear (HEAT1 and HEAT2; manufactured goods, HEAT1: moisture absorbing heat release mechanism, HEAT2: heat storage, release mechanism) were chosen. Thermo-physiological and subjective responses were evaluated at an air temperature of $5.0{\pm}0.5^{\circ}C$ and air humidity of $30{\pm}5%RH$ with five male subjects ($21.6{\pm}1.3yr$ in age, $178.0{\pm}5.9cm$ in height, $68.2{\pm}5.9kg$ in body mass). Experimental conditions consisted of four ensembles that included winter clothes (Control: no underwear, ORD, HEAT1, HEAT2). Water-vapor resistance was greater in fabric of HEAT1 than others. The results were: 1) Total thermal insulation (IT) using a thermal manikin were not greater for HEAT1 (0.860clo) and HEAT 2 (0.873clo) than for ORD (0.886clo). 2) There were no significant differences in rectal temperature, mean skin temperature, heart rate and total body mass loss between the four conditions. Microclimate clothing temperature on the back was greater for ORD than for HEAT1 and HEAT2. Subjects felt more comfortable with HEAT1 than for others at rest. HEAT2 was higher in microclimate humidity when compared to other conditions. The results suggest that thermoregulatory properties of 'heating underwear' in market did not differ from those of ordinary thermal underwear in terms of total thermal insulation and thermoregulatory responses in a cold environment.

몰드 브래지어 컵의 제작을 위한 3D 스페이서 패브릭과 폴리우레탄(PU) 폼 조합에 따른 열·수분 전달 특성 비교 (Comparisons of Thermal-moisture Properties in Combination of 3D spacer and Polyurethane(PU) Foam for Mold Brassiere Cups)

  • 이현영;박희주
    • 한국생활과학회지
    • /
    • 제24권2호
    • /
    • pp.285-295
    • /
    • 2015
  • To identify optimized thermal properties of mold brassiere cup for improved thermal comfort during summer, we compared the thermal resistance and the water vapor permeability of Polyurethane (PU) foam, 3D spacer fabric and the two combined materials of the PU foam and the 3D spacer fabric. Four experimental mold brassieres were made of the materials for wearing test. Six women in their twenties evaluated the wearing sensation in the hot and humid environment. The changes in microclimate temperature and humidity while wearing test brassiere cups were measured. Results indicate that thermal resistance increased as more PU foam were combined, while the water vapor permeability was higher as the content of the 3D spacer fabric increased at thickness of 18mm and over. However, in the wear test, the PU foam brassiere was the most preferred in all ambient conditions due to its soft, flexible and smooth texture, despite its high thermal resistance and low water vapor permeability. This indicates that the textures of mold foams are more dominant properties than thermal properties for mold foams in determining the wear comfort of mold brassieres.

쾌적한 상태에서 계절별 의복을 착용하고 있는 동안 불감증설과 온열 생리 요소들 간의 관련성 (Relationships between Insensible Perspiration and Thermo Physiological Factors during Wearing Seasonal Clothing Ensembles in Comfort)

  • 이주영;최정화;박준희
    • 한국의류학회지
    • /
    • 제31권12호
    • /
    • pp.1700-1709
    • /
    • 2007
  • 본 연구의 목적은 계절별 의복을 착용하고 쾌적한 상태를 유지하는 동안 불감체중손실과 온열 생리적 요소들간의 관련성을 살펴보는 것이다. 이를 위해 한국의 계절별 실내 환경이 인공기후실에 조성되었고 (봄/가을 환경 기온 평균 22.5, 여름 24.7, 겨울 16.8), 설문조사를 바탕으로 총 26 종의 계절별 한벌의복이 선정되었다(봄/가을 옷 8종, 여름 옷 7종, 겨울 옷 11종). 다섯 명의 젊은 여성이 피험자로 참여하였으며, 결과는 다음과 같다: 1) 불감체중손실(IL)은 봄/가을 의복을 착용한 경우 $19{\pm}5g{\cdot}m^{-2}{\cdot}hr$, 여름 옷 $21{\pm}5g{\cdot}m^{-2}{\cdot}hr$, 겨울 옷 $18{\pm}6g{\cdot}m^{-2}{\cdot}hr$으로, 겨울 환경보다 여름 환경에서 더 컸다(p<.001). 2) 호흡기를 통한 불감수분손실(IWR)은 불감체중손실과 반대의 경향을 보여 주어, 겨울옷을 입은 경우 $6{\pm}1g{\cdot}m^{-2}{\cdot}hr$, 여름 옷을 입은 경우 $5{\pm}1g{\cdot}m^{-2}{\cdot}hr$ 였다(p<.001). 3) 불감수분손실 (IW)에서 호흡기를 통한 불감수분손실이 차지하는 비중은 여름 옷을 착용한 경우 평균 28%, 겨울 의복의 경우 38%였다(p<.001). 4) 쾌적한 상태에서, 산열량 중 불감수분손실이 차지하는 비율은 봄/가을 의복을 착용한 경우 25%, 여름옷의 경우 27%, 겨울옷의 경우 23%였다. 5) 불감체중손실과 의복의 보온력 간, 그리고 불감체중손실과 피복면적 간에는 모두 약한 역상관 관계가 관찰되었다. 6) 불감체중손실은 기온, 기습, 에너지 대사, 환기량, 평균피부온도, 의복내 습도 등의 요소와 유의한 상관을 보였으나, 상관계수들은 모두 0.5 이하였다. 결론적으로, 불감체중손실과 온열 생리 요인들 간에는 약한 상관이 존재했으나, 피험자들이 온열 쾌적을 유지하는 경우 착용한 의복 종류 및 노출 기온에 상관없이 불감체중손실량은 좁은 범위를 유지했다.

침구류(寢具類)의 사용(使用) 실태(實態)에 관(關)한 조사(調査) 연구(硏究) - 대구지역(大邱地域)과 전국(全國) 8대(大) 지역(地域)의 비교(比較) - (A Study on Survey of The Actual Use of Bedding - Comparisons Between Taegu and Other Areas -)

  • 정연;성수광
    • 패션비즈니스
    • /
    • 제1권4호
    • /
    • pp.10-18
    • /
    • 1997
  • Sleeping is important for human being in that it has a great effect on their daily activities. Considering that an average adult sleeps seven to eight hours a third of our life is spent in bed. The present study intends to make consumers aware of the important of the bedding science and help the manufactures develop efficient, up-to-date beds. For these two purposes, consumers' recognitions and opinions on the features of the bedding were surveyed. In the study, a questionnaire consisting of various items on the features of the bedding was designed and distributed to consumers in 8 regions & Taegu in Korea to survey the patterns in which they buy, use, and maintain their bedding. The result of the study are as follows; Air conditioner is widely used popular because of hot weather in Taegu. People in Taegu mostly purchase their bedding from market, in every 5~6 years. The important point to be considered for bedding purchases were humidity absorption, air permeability, light weight in summer comforters, thermal insulation, flexibility, color figure design in winter comforters, humidity absorption, flexibility, color figure design in mats. As summer bedding, a sheet of single-layer quilt and rush mat were most popular which indicates climate of hot and humid weather in Taegu. Bedding uses in winter were in order a sheet of cotton, silk, wool quilt, and silk quilt showed high level in contrast to other areas. Dissatisfactions with summer quilts were humidity absorption, air permeability, heaviness and in winter quilts they were dissatisfied with thermal insulation, heaviness, flattening. In details about bedding managements, people in Taegu most frequently disinfected their bedding by sunlight in one month, and refinished every 5 years.

  • PDF

발열장치를 이용한 기능성 스마트 파운데이션의 구성 시안 (Prototype of Smart Foundation with Heating Devices)

  • 황영미;이정란
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.588-596
    • /
    • 2012
  • This research was intended to design an experimental girdle with thermal insulation function for adult women in their 20s. The design of the experimental girdle was based on the pattern of commercially available girdle. The final pattern of the experimental girdle was established according to the drawing equations determined based on the result of appearance evaluation. The equations were (waist circumference${\times}0.88$)/2 for waist circumference, (hip circumference${\times}0.77$)/2 for hip circumference, and (thigh circumference${\times}0.85$) for thigh circumference. In order to develop a heating device, the most effective fabric heater was adopted based on the experiments about the number of caron fibers, heater size and attachment site. Three heaters-one with a size of $14.5{\times}9.5$ cm, and the other two with the size of $8.0{\times}15.0$ cm-were attached to the areas corresponding to the lower abdomen and the hip, 5 cm below the waist. A heater was developed by connecting these heaters to a controller, 2 batteries (7.4 V 2000 mAh lithium polymer batteries) and a switch (for mode conversion between high/medium/low temperatures). The heater was integrated into the inside of the girdle, so that attachment and detachment were possible without the change of appearance. The tentative configuration plan was proposed for the development of a functional smart girdle with an excellent thermal insulation effect.

Analysis of optimal activities according to thermal comfort in the forest: focusing on a program for the elderly at the National Forest Therapy Center

  • Tae-Gyu Khil;Ah-Young Jung;Kun-Woo Park;Yang-Soon Oh;Beom Lee;Dawou Joung;Hyelim Lee;Bum-Jin Park
    • 농업과학연구
    • /
    • 제50권4호
    • /
    • pp.663-673
    • /
    • 2023
  • The purpose of this study was to scientifically activate the forest healing program activities for the elderly. The predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), which are indices of thermal comfort in the thermal environment, and degree of canopy closure were compared and analyzed. Based on this information, the study objective was to present the appropriate conditions for maintaining the best comfort for the elderly. Six deck road shelters, which are the most active locations in forest healing programs among the National Center for Forest Therapy, were selected as the study sites. The results indicated that in the case of the conditions of 1 clo (clothing insulation value) and 1 met (metabolic rate) at an air temperature of 19 to 21 degrees in September on the measurement date, the PMV values ranged between -1.85 and -0.98 at all sites, and PPD values ranged between 25.60% and 68.68%. On the other hand, in the case of 1.3 clo and 1.6 met conditions, the PMV values ranged between -0.08 and 0.23 for all sites and PPD values ranged between 5.40 and 6.18. As shown above, the difference in thermal environment comfort and satisfaction according to the condition of the amount of metabolism and the amount of clothing could be confirmed. In addition, an analysis of the relation between PPD and canopy closure suggested a significantly positive correlation between them, and it was found that canopy closure was a factor affecting thermal comfort. Studies on effects of forest thermal environmental comfort and canopy closure on forest healing program areas should be conducted extensively according to seasonal conditions to provide information that can be used for more effective forest healing programs.