• Title/Summary/Keyword: thermal indicator

Search Result 95, Processing Time 0.023 seconds

Development of Plasma Reactor of Dielectric Barrier Discharge for Water Treatment (수처리용 유전체 장벽 방전 플라즈마 반응기 개발)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.5
    • /
    • pp.597-603
    • /
    • 2012
  • Non-thermal plasma processing using a dielectric barrier discharge (DBD) has been investigated as an alternative method for the degradation of non-biodegradable organic compounds in wastewater. The active species such as OH radical, produced by the electrical discharge may play an important role in degrading organic compound in water. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO) was investigated as an indicator of the generation of OH radical. The DBD plasma reactor of this study consisted of a plasma reactor, recycling pump, power supply and reservoir. The effect of diameter of external reactor (15 ~ 40 mm), width of ground electrode (2.5 ~ 30 cm), shape (pipe, spring) and material (copper, stainless steel and titanium) of ground electrode, water circulation rate (3.1 ~ 54.8 cm/s), air flow rate (0.5 ~ 3.0 L/min) and ratio of packing material (0 ~ 100 %) were evaluated. The experimental results showed that shape and materials of ground were not influenced the RNO degradation. Optimum diameter of external reactor, water circulation rate and air flow rate for RNO degradation were 30 mm, 25.4 cm/s and 4 L/min, respectively. Ground electrode length to get the maximum RNO degradation was 30 cm, which was same as reactor length. Filling up of glass beads decreased the RNO degradation. Among the experimented parameters, air flow rate was most important parameters which are influenced the decomposition of RNO.

A Study for Reduction of Combustion Noise in Diesel Engine by Wiebe's Combustion Function (Wiebe 燃燒函數에 의한 디이젤機關 의 燃燒騷音低減 에 관한 硏究)

  • 이성노;궁본등;촌산정;노상순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.548-554
    • /
    • 1985
  • This research is to find a means of reducing diesel engine combustion noise with none or minimum sacrifice of engine performance by investigating the influence of Cylinder Pressure Level(CPL). For this purpose, modified Wiebe's combustion function, considering the heat release curve as a combustion of both premixed and diffusive combustion portion, was exclusively used to obtain the indicator diagram and computer coeds were developed for the numerical analysis. Following are the results of this research. (1) CPL increases almostly with lag of ignition timing increasing .alpha. and decreasing. theta.$_{d}$, but at the crank angle with the maximal efficiency, CPL is independent of .alpha. and .theta.$_{d}$ with constant value of 200 dB especially at the low frequency. (2) For the constant ignition timing, the effects of .alpha. and .theta.$_{d}$ on CPL were the most significant at the frequency of about 1KHz and 300Hz respectively. (3) For the constant value of .alpha. and .theta.$_{d}$, CPL increases linearly with load but thermal efficiency increase very rapidly with maximum value of load Q$_{T}$=30-40 MJ/Kmol, then starts to decrease slowly. (4) The most effective way of reducing combustion noise without sacrificing thermal efficiency, is to decrease .alpha.. In the case of constant .alpha., there always exists a optimum value of .theta.$_{d}$ with respect to the various compression ratio.o..atio.o..

A study on thermal simulation for extensive green roof system using a plant canopy model (식생캐노피모델을 통한 저관리 조방형 옥상녹화시스템의 열해석 전산모의에 관한 연구)

  • Kim, Tae Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • GRS is an effective urban ecology restoration technique that can manage a variety of environmental functions such as ecological restoration, rainwater spill control and island heat effect from a low-impact development standpoint that can be utilized in new construction and retrofits. Recently, quantitative evaluation studies, both domestic and abroad, in the areas related to these functions, including near-earth surface climate phenomenon, heavy rainwater regulation, thermal environment of buildings, have been actively underway, and there is a trend to standardize in the form of technological standards. In particular, centered on the advanced European countries, studies of standardizing the specific insulation capability of buildings with green system that comprehensively includes the green roof, from the perspective of replacing the exterior materials of existing buildings, are in progress. The limitation of related studies in the difficulties associated with deriving results that reflect material characteristics of continuously evolving systems due in part to not having sufficiently considered the main components of green system, mechanisms of vegetation, soils. This study attempts to derive, through EnergyPlus, the effects that the vegetation-related indicators such as vegetation height, FCV, etc. have on building energy load, by interpreting vegetation and soil mechanisms through plant canopy model and using an ecological standard indicator LAI that represent the condition of plant growth. Through this, the interpretations that assume green roof system as simple heat insulation will be complemented and a more practical building energy performance evaluation method that reflects numerical methods for heat fluxes phenomena that occur between ecology restoration systems comprised of plants and soil and the ambient space.

Change of Climatic Growing Season in Korea (한반도의 기후학적 식물생육기간의 변화)

  • Jung, Myung-Pyo;Shim, Kyo-Moon;Kim, Yongseok;Choi, In-Tae
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.3
    • /
    • pp.192-195
    • /
    • 2015
  • BACKGROUND: The growing season (GS) has been understood as a useful indicator for climate change due to high relationship with increasing temperature. Hear this study was conducted to examine changes in the thermal GS over South Korea from 1970 to 2013 based on daily mean air temperature for assessing the temporal and spatial variability in GS. METHODS AND RESULTS: Three GS parameters (starting date, ending date, and length) were determined at 19 stations throughout South Korea. The results show that the GS has been extended by 4.2 days/decade between 1970 and 2013 on average. The growing season start (GSS) has been advanced by 2.7 days/decade and the growing season end (GSE) has been delayed by 1.4 day/decade. Spatial variation in the GS parameters in Korea are shown. The GS parameters, especially GSS, of southeastern part of Korea have been changed more than that of northwestern part of Korea. The extension of GS may be more influenced on earlier onset in spring rather than later GSE. CONCLUSION: Under climate change scenarios, the GS will be more extended due to delayed GSE as well as advanced GSS. And These are more notable in the northeastern part of Korea.

Analyses on Comparison of UTCI, PMV, WBGT between Playground and Green Space in School (학교 운동장과 녹지공간의 UTCI, PMV, WBGT 비교 분석)

  • Yoon, Young-Han;Park, Seung-Hwan;Kim, Won-Tae;Kim, Jeong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.1
    • /
    • pp.80-89
    • /
    • 2014
  • This study of the school's outdoor space for relaxing and activity of the two most numerous students, high heat and low heat with a green space, playground targets of thermal comfort indicators UTCI, PMV, WBGT using the thermal comfort students feeling compare the analyzed. The destination of this study, school facilities of Nam-gu, Namdong- gu, Incheon were studied and the investigation period was conducted from July to August. List of measurement, in the case of thermal comfort indicators, UTCI, PMV, WBGT was measured in the case of green, ratio of green coverage and GVZ was measured. GVZ analysis were as follows: A school ($4.71m^3/m^2$) B school ($3.34m^3/m^2$) C school ($0.38m^3/m^2$). Comparative analysis of the results of thermal comfort indicators by schools, UTCI was Green space $26.15{\sim}31.38^{\circ}C$ and playground $40.66{\sim}42.94^{\circ}C$, PMV values were 1.76 to 2.66 as a green space. WBGT was Green space $26.15{\sim}31.38^{\circ}C$, playground $31.67{\sim}34.53^{\circ}C$. Comparative analysis of the results of thermal comfort indicators UTCI, PMV, WBGT all A school, B school, C school, on the green space was comfortable levels more than playground. The results of the school type thermal comfort and green correlation analysis of thermal comfort UTCI, PMV, WBGT all solar radiation, globe temperature, and a positive correlation shown solar radiation, globe temperature is not comfortable, the higher was considered. UTCI, PMV, WBGT of thermal comfort indicator all ratio of green coverage, GVZ and negative correlation appears ratio of green coverage, GVZ was increased due to the lowering of the value of thermal comfort indicators was considered to be comfortable.

Acoustic Analysis for Thermal Environment-related Vocalizations in Laying Hens (산란계의 열환경별 특이음에 대한 음성학적 분석)

  • Jeon, J.H.;Yeon, S.C.;Ha, J.K.;Lee, S.J.;Chang, H.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.697-702
    • /
    • 2005
  • The aim of this study was to divide vocalizations of laying hens (Hy-Line Brown) into general vocalizations (GVs), heat stress-related vocalization (HSV), and cold stress-related vocalizations (CSVs) and to determine if they are classified by the discriminant function analysis method. Thirty laying hens, 65-wk-old, were recorded using digital video recorders 2 times from 10:00 to 14:00 h in each thermal environment (thermoneutral: $22.0{\pm}1.8^{\circ}C$, too hot: $32.0{\pm}2.0^{\circ}C$, too cold: $8.0{\pm}1.9^{\circ}C)$ after a 7 day acclimation period. When the laying hens were not recorded, they were kept in thermoneutral conditions. The GVs, HSV, and CSVs were divided based on the shapes of spectrums and spectrograms. The GVs, HSV, and CSVs were identified as 5, 1, and 3 types, respectively. Pitch, intensity, duration, formant 1, formant 2, formant 3, and formant 4 among the thermal environment-related vocalizations were significantly different (P<0.001). The discrimination rate determined by discriminant function analysis was 86.2%. These results suggest that HSV and CSVs are present and may be used as an indicator of the thermal environment.

Thermal Inactivation of Crude Papain and Papaya Peroxidase (Papaya중의 단백질 분해 효소와 Peroxidase의 열 불활성화)

  • Park, Kwan-Hwa;Kim, Ze-Uook;Shin, Jae-Doo;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.171-175
    • /
    • 1979
  • Thermal properties of crude papain and crude peroxidase from domestic papaya were investigated. The crude extract of papaya was inactivated at the temperature range of $60^{\circ}{\sim}90^{\circ}C$ at pH 7.0 and the rest of the activities of papain and peroxidase were determined, respectively. The heat inactivation of papain and papaya peroxidase was biphasic at low temperature. For the thermal inactivation of papain extract, the enthalpy of activation was 91.4 kJ/mol, the entropy of activation, -49.6 J/mol K, and the free energy of activation, 108.5 kJ/mol. The activation energy for the inactivation of papaya peroxidase was 168.5 kJ/mol, the entropy of activation, $200.4\;J/mol{\cdot}K$ and the free energy of activation, 99.7 kJ/mol. The thermal stability of papain showed that it has a possibility for use as a meat tenderizer. It was also discussed that papaya peroxidase could be more suitable as a biochemical criteria for heat treatment than papaya catalase.

  • PDF

Failure Study for Tribological Characteristics Including with Pad, Lining and Hub disk in Vehicle Brake System (자동차 제동시스템의 패드, 라이닝, 허브디스크에 관련된 트라이볼로지적인 특성에 관한 고장사례연구)

  • Lee, Il-Kwon;Kim, Chung-Kyun;Cho, Seung-Hyun
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.269-274
    • /
    • 2011
  • The purpose of this paper is to study and analyze the improvement method for the failure examples including the vehicle brake system in actual field. It was verified that the indicator plate of pad wear scratched the brake disk because of wearing after displacement of non- identification parts pad. The caliper of other vehicle was installed with brake system verified the phenomenon produced groove in center point because of one side wear when the pad was not fully contacted with the rub disk by other action surface pressure and pad action condition. It verified that the crack phenomenon fatigue was produced by brake thermal deformation because of decreasing the thickness by grinding to modify the non-uniformed wear of brake disk. It verified that the friction sound was produced by the friction phenomenon because of non-uniformed contact of lining and an alien substance with inner of the drum and lining braking by crack phenomenon with brake drum surface.

Comparative Performance Evaluation of 10kV IGCTs in 3L ANPC and TNPC Converters in PMSG MV Wind Turbines (PMSG 풍력발전기용 3L ANPC와 TNPC 컨버터에서의 10kV IGCT 성능 비교 평가)

  • Lyngdoh, Amreena Lama;Suh, Yongsug;Park, Byoung-Gun;Kim, Jiwon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.419-427
    • /
    • 2019
  • Several multilevel converter topologies have been proposed and compared. The three-level (3L) neutral-point-clamped (NPC) topology is promising and widely accepted. However, this topology suffers from uneven loss distribution among switches due to its fixed switching strategy. The 3L active NPC (ANPC) topology, which exhibits improved loss distribution profile, was proposed to address this disadvantage. The 3L T-NPC topology, a hybrid configuration of 2L and 3L NPC topologies, was introduced to address not only the loss distribution problem but also the reduction in the number of switches. In the present research, the application of these three topologies in PMSG-based medium-voltage wind turbines was investigated. The power devices considered were 10 kV IGCTs. Performance was evaluated in terms of a power loss of 10 kV IGCT for each NPC topology, which is a crucial indicator of thermal behavior, reliability, cost, and lifetime of any converter. The comparison was performed using ABB make 10 kV IGCT 5SHY17L9000 and the simulation tool PLECS.

Continuous Measurements of Aromatic VOCs in a Mid-eastern Region of Seoul during Winter 2002/2003 (방향족 휘발성 유기화합물의 겨울철 연속 관측 연구)

  • 최여진;오상인;김기현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.491-502
    • /
    • 2003
  • In the present work, the distribution characteristics of ambient volatile organic compounds (VOCs) were investigated at high temporal resolution from a monitoring station located in a mid-eastern area of Seoul. A total number of 587 samples were collected during December 2002 to January 2003. The measurements of VOC were conducted by a combination of on-line air sampling and thermal desorption unit (TDU) coupled with capillary GC/FID analysis. A total of five aromatic compounds (BTEX: benzene, toluene, ethylbenzene, m, p-xylene, and o-xylene) were measured routinely at hourly intervals during the whole study period. The mean concentrations of BTEX measured in our study period were found in the order: toluene (8.99 $\pm$5.38 ppb) > benzene (0.92$\pm$0.52 ppb) > m, p-xylene (0.51$\pm$0.34 ppb) > 0- xylene (0.48$\pm$0.35 ppb) > ethyl benzene (0.43$\pm$ 0.32 ppb). The BTEX concentrations were generally higher during the daytime than the nighttime, exhibiting certain patterns on a weekly basis. Results of our analysis indicate that the unusually high concentrations of toluene, while showing good correlations with other VOCs, can be a good indicator of air pollution in the study area.