• Title/Summary/Keyword: thermal imaging

Search Result 619, Processing Time 0.032 seconds

Assessment of soil moisture-vegetation-carbon flux relationship for agricultural drought using optical multispectral sensor (다중분광광학센서를 활용한 농업가뭄의 토양수분-식생-이산화탄소 플럭스 관계 분석)

  • Sur, Chanyang;Nam, Won-Hob
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.721-728
    • /
    • 2023
  • Agricultural drought is triggered by a depletion of moisture content in the soil, which hinders photosynthesis and thus increases carbon dioxide (CO2) concentrations in the atmosphere. The aim of this study is to analyze the relationship between soil moisture (SM) and vegetation activity toward quantifying CO2 concentration in the atmosphere. To this end, the MODerate resolution imaging spectroradiometer (MODIS), an optical multispectral sensor, was used to evaluate two regions in South Korea for validation. Vegetation activity was analyzed through MOD13A1 vegetation indices products, and MODIS gross primary productivity (GPP) product was used to calculate the CO2 flux based on its relationship with respiration. In the case of SM, it was calculated through the method of applying apparent thermal inertia (ATI) in combination with land surface temperature and albedo. To validate the SM and CO2 flux, flux tower data was used which are the observed measurement values for the extreme drought period of 2014 and 2015 in South Korea. These two variables were analyzed for temporal variation on flux tower data as daily time scale, and the relationship with vegetation index (VI) was synthesized and analyzed on a monthly scale. The highest correlation between SM and VI (correlation coefficient (r) = 0.82) was observed at a time lag of one month, and that between VI and CO2 (r = 0.81) at half month. This regional study suggests a potential capability of MODIS-based SM, VI, and CO2 flux, which can be applied to an assessment of the global view of the agricultural drought by using available satellite remote sensing products.

Topology Design Optimization and Experimental Validation of Heat Conduction Problems (열전도 문제에 관한 위상 최적설계의 실험적 검증)

  • Cha, Song-Hyun;Kim, Hyun-Seok;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.9-18
    • /
    • 2015
  • In this paper, we verify the optimal topology design for heat conduction problems in steady stated which is obtained numerically using the adjoint design sensitivity analysis(DSA) method. In adjoint variable method(AVM), the already factorized system matrix is utilized to obtain the adjoint solution so that its computation cost is trivial for the sensitivity. For the topology optimization, the design variables are parameterized into normalized bulk material densities. The objective function and constraint are the thermal compliance of the structure and the allowable volume, respectively. For the experimental validation of the optimal topology design, we compare the results with those that have identical volume but designed intuitively using a thermal imaging camera. To manufacture the optimal design, we apply a simple numerical method to convert it into point cloud data and perform CAD modeling using commercial reverse engineering software. Based on the CAD model, we manufacture the optimal topology design by CNC.

Oxytocin produces thermal analgesia via vasopressin-1a receptor by modulating TRPV1 and potassium conductance in the dorsal root ganglion neurons

  • Han, Rafael Taeho;Kim, Han-Byul;Kim, Young-Beom;Choi, Kyungmin;Park, Gi Yeon;Lee, Pa Reum;Lee, JaeHee;Kim, Hye young;Park, Chul-Kyu;Kang, Youngnam;Oh, Seog Bae;Na, Heung Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.2
    • /
    • pp.173-182
    • /
    • 2018
  • Recent studies have provided several lines of evidence that peripheral administration of oxytocin induces analgesia in human and rodents. However, the exact underlying mechanism of analgesia still remains elusive. In the present study, we aimed to identify which receptor could mediate the analgesic effect of intraperitoneal injection of oxytocin and its cellular mechanisms in thermal pain behavior. We found that oxytocin-induced analgesia could be reversed by $d(CH_2)_5[Tyr(Me)^2,Dab^5]$ AVP, a vasopressin-1a (V1a) receptor antagonist, but not by $desGly-NH_2-d(CH_2)_5[D-Tyr^2,Thr^4]OVT$, an oxytocin receptor antagonist. Single cell RT-PCR analysis revealed that V1a receptor, compared to oxytocin, vasopressin-1b and vasopressin-2 receptors, was more profoundly expressed in dorsal root ganglion (DRG) neurons and the expression of V1a receptor was predominant in transient receptor potential vanilloid 1 (TRPV1)-expressing DRG neurons. Fura-2 based calcium imaging experiments showed that capsaicin-induced calcium transient was significantly inhibited by oxytocin and that such inhibition was reversed by V1a receptor antagonist. Additionally, whole cell patch clamp recording demonstrated that oxytocin significantly increased potassium conductance via V1a receptor in DRG neurons. Taken together, our findings suggest that analgesic effects produced by peripheral administration of oxytocin were attributable to the activation of V1a receptor, resulting in reduction of TRPV1 activity and enhancement of potassium conductance in DRG neurons.

Optimum Wattage and Installation Height of Nano-Carbon Fiber Infrared Heating Lamp for Heating Energy Saving in Plug Seedling Production Greenhouse in Winter Season (동절기 공정육묘장의 난방 에너지 절감을 위한 나노탄소섬유적외선 난방등의 적정 전력과 설치 높이)

  • Kim, Hye Min;Kim, Young Jin;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.302-307
    • /
    • 2016
  • The aim of this study was to examine the optimum wattage and installation height using nano-carbon fiber infrared heating lamp (NCFIHL) for heating energy saving and plug seedling production in plug seedling production greenhouse in winter season. NCFIHL of 700 and 900 W was installed over the bed ($1.2{\times}2.4m$) as 0.7, 1.0, and 1.3 m height, respectively, for the production of grafted watermelon seedling in venlo-type glasshouse. Watermelon (Citrullus lanatus (Thunb.) Manst.) 'Jijonggul' and gourd (Lagenaria leucantha Rusby.) 'Sunbongjang' were used as scions and rootstocks, respectively. The scions and rootstocks were grafted by single cotyledon ordinary splice grafting. Light intensity of NCFIHL was below the $1{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ in all treatment. Spectral distributions of NCFIHL presented mostly infrared area. When outside air temperature was below $10^{\circ}C$, 700 and 900 W NCFIHL installed with 0.7 m height treatment and 900 W NCFIHL installed with 1.0 m height treatment maintained the setting air temperature ($20^{\circ}C$) at night. In the result of taking thermal imaging, the grafted watermelons were getting warm fast in 900 W NCFIHL installed with 0.7 m height treatment at night. Compactness of the grafted watermelons was the greatest in 700 W NCFIHL installed with 1.3 m height treatment. The results indicate that NCFIHL installed above 1.0 m height using 700 W was suitable for production of plug seedling.

Effects of Non-combustible moxibustion on Thermography of Healthy Human Beings (비연소식(非燃燒式) 구법(灸法) 재료(材料)를 이용한 온열자극(溫熱刺戟)이 체열방사(體熱放射)에 미치는 효과)

  • Choi, Won-Jong;Kim, Jae-Hyo;Kim, Kyung-Sik;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.21 no.3
    • /
    • pp.21-38
    • /
    • 2004
  • Objectives : Moxibustion has been become very useful tool to prevent and treat various diseases with acupuncture in oriental medicine. Expecially, moxibustion combining the heat stimulation and chemical stimulation of Artemisiae Argyi has a non-invasive characteristics comparing to the other therapeutic tools. However, because the moxibustion makes the patient's skin be burn by the combustible feature of moxibustion, most of people have been scared of being scald. Methods : In this study, we have developed new non-combustible moxibustion tools in collaboration with company (Hana Medical, co. and ICURE, co.) and tested the efficacy through effects of moxibustion of Cheon-chu $(ST_{25})$ on the abdominal thermography of health subject. The non-combustible moxibustion has main characteristics of controlled heating to inhibit being scald and heat stimulation lasting over 1 hrs. Also, to induce the chemical stimulation, the bottom contacting with skin was coated by the extract of artemisiae argyi. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes. Results : The results showed that moxibustion of Cheon-chu $(ST_{25})$ had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, it was observed that the quantities of thermal changes following moxibustion of Cheon-chu $(ST_{25})$ been increased significantly comparing that of control group at all the ROIs (region of interest). Observed the thermography classified by ROI, however, moxibustion of Cheon-chu $(ST_{25})$ could modulate ipsilateral specific areas concerning to the abdominal pathway of Stomach Meridian. Conclusion : These results suggest that new non-combustible moxibusion has some similarity as like as the conventional moxibustion and moxibustion of Cheon-chu $(ST_{25})$ may modulate thermal changes of abdominal areas.

  • PDF

DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC (MIRIS 우주관측카메라의 기계부 개발)

  • Moon, B.K.;Jeong, W.S.;Cha, S.M.;Ree, C.H.;Park, S.J.;Lee, D.H.;Yuk, I.S.;Park, Y.S.;Park, J.H.;Nam, U.W.;Matsumoto, Toshio;Yoshida, Seiji;Yang, S.C.;Lee, S.H.;Rhee, S.W.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

Scientific Investigation and Conservation Treatment of the Three-story Stone Pagoda at Jangha-ri, Buyeo (부여 장하리 삼층석탑의 과학적 조사 및 보존처리)

  • Kim, Joohyung;Han, Minsu
    • Conservation Science in Museum
    • /
    • v.27
    • /
    • pp.103-124
    • /
    • 2022
  • This study examined the properties of the materials used in the three-story pagoda at Jangha-ri, Buyeo. It was performed in order to identify the objective condition of the pagoda and establish an appropriate plan for the conservation treatment of the pagoda. According to the study, the average total magnetic susceptibility was 3.71 (10-3 SI unit), and at least four types of granite with different origins were likely used in the production of the pagoda. The ultrasonic velocity averaged 1,519m/s, and the coefficient of weathering showed an average of grade 4. The thermal gradient between the cement (restoration materials) and original materials was identified through thermal imaging. In some areas, the cement restoration materials required replacement with new stone materials with properties similar to those of the original stone materials. Taking into account these results, a map of weathering damage was prepared and appropriate conservation treatment plans were established based on the findings of previous studies. Since the pagoda had suffered severe biological damage and discoloration, surface contaminants were removed through wet cleaning with distilled water and a brush. The exfoliated areas were reinforced on the site by mixing epoxy resin with powdered stone with the same properties as the original stone materials of the pagoda.

Correlation Analysis of Cutter Acting Force and Temperature During the Linear Cutting Test Accompanied by Infrared Thermography (선형절삭시험과 적외선 열화상 측정을 통한 픽커터 작용력과 발생 온도의 상관관계 분석)

  • Soo-Ho Chang;Tae-Ho Kang;Chulho Lee;Hoyoung Jeong;Soon-Wook Choi
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.519-533
    • /
    • 2023
  • In this study, the linear cutting tests of pick cutters were carried out on a granitic rock with the average compressive strength over 100 MPa. From the tests, the correlation between the cutter acting force and the temperature measured by infrared thermal imaging camera during rock cutting was analyzed. In every experimental condition, the maximum temperature was measured at the rock surface where the chipping occurred, and the temperature generated in the rock was closely correlated with the cutter acting force. On the other hand, the temperature of a pick cutter increased up to only 36℃ above the ambient temperature, and the correlation with the cutter force was not obvious. This can be attributed to the short cutting distance under laboratory conditions and the high thermal conductivity of the tungsten carbide inserts. However, the relatively high temperature of the tungsten carbide inserts was found to be maintained. Therefore, it is recommended that a reinforcement between the insert and the head of a pick cutter or the quality improvement of silvering brazing in the production of a cutter is necessary to maintain the high cutting performance of a pick cutter.

Denoising of Infrared Images by an Adaptive Threshold Method in the Wavelet Transformed Domain (웨이브렛 변환 영역에서 적응문턱값을 이용한 적외선영상의 잡음제거)

  • Cho, Chang-Ho;Lee, Sang-Hyo;Lee, Jong-Yong;Cho, Do-Hyeon;Lee, Sang-Chuel
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.65-75
    • /
    • 2006
  • This thesis deals with a wavelet-based method of denoising of infrared images contaminated with impulse noise and Gaussian noise, he method of thresholding the wavelet coefficients using derivatives and median absolute deviations of the wavelet coefficients of the detail subbands was proposed to effectively denoise infrared images with noises. Particularly, in order to eliminate the impulse noise the method of generating binary masks indicating locations of the impulse noise was selected. By this method, the threshold values dividing edges and noises were obtained more effectively proving the validity of the denoising method compared with the conventional wavelet shrinkage method.

An Experimental study on the human's physiological in Smart Textile Materials by Using Medical Infrared Thermo graphic Imaging (적외선 체열 영상 진단법을 이용한 스마트 섬유소재와 휴대폰 통화량에 따른 인체 생리반응 연구)

  • Lee Tae-il;Lee Su-jeong;Lee Kyung-mi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.7 s.144
    • /
    • pp.918-925
    • /
    • 2005
  • The following are the results from the infrared body temperature image test to verify the changes in facial temperature according to call duration with a cellular phone. As for the body temperatures, it appears to be the mean value at the upper central point of phone's battery among 7 different points that are measured, and to be the highest at srernocleido-mastoid and scapular trapezius muscle triangle zone$(34.25^{\circ}C\; and\;34.05^{\circ}C\;each)$. The changes of body temperature according to the time duration shows that the body temperature rises according to the length of phone use because of the heat emitted from the battery. As for the temperature changes according to blocking materials, the one without processing appears to be higher in the mean temperature compared to the others that are processed, NSS(Nano Silver Silk) and NSG(Nano Silver Silk Gold) appear to be the lowest in the temperature to show the best blocking property. As for the temperature changes according to measuring points, it appears to be the highest at P4, P5 with all materials, and one with NSG to be the lowest at Pl, P2, P3, and one with NSS to be the lowest at P3, P4, P5, P6, which is due to the thermal conduction of Au and Ag. And the mean temperature at each point appears to be different according to the materials. Therefore, the study conducted with human participants requires a proper particle size of it which would not penetrate cellular tissues and a proper binder and binding treatment for it, to prevent the physical fatigues and the potential diseases. However, it is highly required for back-up researches to verify various aspects in applying nano silver to textile products.