• 제목/요약/키워드: thermal imaging

검색결과 622건 처리시간 0.029초

작동중인 모스 전계 효과 트랜지스터 단면에서의 상대온도 및 전위 분포 측정 (Cross Sectional Thermal and Electric Potential Imaging of an Operating MOSFET)

  • 권오명
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.829-836
    • /
    • 2003
  • Understanding of heat generation in semiconductor devices is important in the thermal management of integrated circuits and in the analysis of the device physics. Scanning thermal microscope was used to measure the temperature and the electric potential distribution on the cross-section of an operating metal-oxide-semiconductor field-effect transistor (MOSFET). The temperature distributions were measured both in DC and AC modes in order to take account of the leakage current. The measurement results showed that as the drain bias was increased the hot spot moved to the drain. The density of the iso-potential lines near the drain increased with the increase in the drain bias.

Simple Graphical Selection of Optical Materials for an Athermal and Achromatic Design Using Equivalent Abbe Number and Thermal Glass Constant

  • Kim, Young-Ju;Kim, Yeong-Sik;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.182-187
    • /
    • 2015
  • This paper presents a new graphical method for selecting a pair of optical glasses to simultaneously achromatize and athermalize an imaging lens made of materials in contact. An athermal glass map that plots thermal glass constant versus inverse Abbe number is derived through analysis of optical glasses and plastic materials in visible light. By introducing the equivalent Abbe number and equivalent thermal glass constant, although it is a multi-lens system, we have a simple way to visually identify possible optical materials. Applying this method to design a phone camera lens equipped with quarter inch image sensor having 8-mega pixels, the thermal defocuses over $-20^{\circ}C$ to $+60^{\circ}C$ are reduced to be much less than the depth of focus of the system.

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • 오규환;강파;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

Plateau equalization 알고리즘을 적용한 실시간 열영상 대조비 개선에 관한 연구 (A study on the application of Plateau equalization algorithm for contrast enhancement of real-time thermal image)

  • 조흥기;김수곤;이정복;이원선;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.186-189
    • /
    • 2002
  • Real-time thermal image is obtained by thermal imaging systems measuring radiant emittence according to law of Plank's blackbody radiation. The histogram of thermal image is not uniform. The signal bands of background and target are separated and grouped in narrow bands. In such a system, contrast enhancement indispensible to distinguish target from background. In this study, plateau histogram equalization using local histogram is proposed for contrast enhancement.

  • PDF

MOSAICFUSION: MERGING MODALITIES WITH PARTIAL DIFFERENTIAL EQUATION AND DISCRETE COSINE TRANSFORMATION

  • GARGI TRIVEDI;RAJESH SANGHAVI
    • Journal of Applied and Pure Mathematics
    • /
    • 제5권5_6호
    • /
    • pp.389-406
    • /
    • 2023
  • In the pursuit of enhancing image fusion techniques, this research presents a novel approach for fusing multimodal images, specifically infrared (IR) and visible (VIS) images, utilizing a combination of partial differential equations (PDE) and discrete cosine transformation (DCT). The proposed method seeks to leverage the thermal and structural information provided by IR imaging and the fine-grained details offered by VIS imaging create composite images that are superior in quality and informativeness. Through a meticulous fusion process, which involves PDE-guided fusion, DCT component selection, and weighted combination, the methodology aims to strike a balance that optimally preserves essential features and minimizes artifacts. Rigorous evaluations, both objective and subjective, are conducted to validate the effectiveness of the approach. This research contributes to the ongoing advancement of multimodal image fusion, addressing applications in fields like medical imaging, surveillance, and remote sensing, where the marriage of IR and VIS data is of paramount importance.

위상 잠금 열화상 기법을 이용한 콘크리트 마감재 내부 균열 검출 (Concrete Crack Detection Inside Finishing Materials Using Lock-in Thermography)

  • 이명훈;우욱용;최하진;김종찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.30-38
    • /
    • 2023
  • 안전점검 대상 노후 건축물이 증가함에 따라 안전관리 주체인 지정기관 및 관리주체의 부담이 증가하고 있다. 이에 안전점검 대상 건축물 선정에 있어 적절한 안전전검 기준과 그에 따르는 적절한 기술은 필수적이다. 현행 노후 건축물 대상 안전점검 수행 기준은 마감재로 인해 구조 부재 균열 등의 손상 확인이 어려울 경우 낮은 점수를 부여하고 있다. 이는 구조물의 실체 안전상태와 관계없이 평가 결과가 과소평가되어 안전점검 대상 노후화 건축물을 증가시키는 원인이다. 이에 본 연구에서는 마감재 내부의 균열 탐지를 위해 비파괴·비접촉 검사인 열화상 기법을 제안하였다. 열화상 카메라를 이용한 마감재 내부 균열 관측을 위해 콘크리트 시편을 제작하였으며, 콘크리트 표면 및 균열부에 열원을 가진하여 열화상 데이터를 계측하였다. 계측 결과, 너비 0.3mm, 0.5mm, 0.7mm의 마감재 내부 균열 관측이 가능함을 확인하였으나, 표면 박리, 도배지 들뜸으로 인한 불균일한 온도 분포로 인해 균열 판단이 어렵다. 이에 열화상 데이터의 진폭 및 위상 차이를 도출하여 데이터 분석을 수행한 결과, 0.5mm, 0.7mm 균열에 대해 선명한 균열 계측이 가능하였다. 본 연구를 토대로 추후 마감재 내부 균열 손상 진단에 있어 빅 데이터 기반 딥러닝을 이용한 기술개발을 통해 현장적용 및 분석의 효율성을 증대시키고자 한다.

Simulation Research on the Thermal Effects in Dipolar Illuminated Lithography

  • Yao, Changcheng;Gong, Yan
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.251-256
    • /
    • 2016
  • The prediction of thermal effects in lithography projection objective plays a significant role in the real-time dynamic compensation of thermal aberrations. For the illuminated lithography projection objective, this paper applies finite element analysis to get the temperature distribution, surface deformation and stress data. To improve the efficiency, a temperature distribution function model is proposed to use for the simulation of thermal aberrations with the help of optical analysis software CODE V. SigFit is approved integrated optomechanical analysis software with the feature of calculating OPD effects due to temperature change, and it is utilized to prove the validation of the temperature distribution function. Results show that the impact of surface deformation and stress is negligible compared with the refractive index change; astigmatisms and 4-foil aberrations dominate in the thermal aberration, about 1.7 λ and 0.45 λ. The system takes about one hour to reach thermal equilibrium and the contrast of the imaging of dense lines get worse as time goes on.

해저배관 뒤채움 흙의 열전도율 산정에 관한 실험 및 수치 해석적 연구 (Experimental and Numerical Methods for Thermal Conductivity of Backfill Soils for Subsea Pipeline)

  • 박동수;서영교
    • 한국해양공학회지
    • /
    • 제31권2호
    • /
    • pp.103-110
    • /
    • 2017
  • The temperature of subsea pipeline, approximately as high as $100^{\circ}C$, is significantly higher than the temperature of surrounding sea water and sediment. In this reason, heat can be lost from the subsea pipeline to cause serious operation problem. Therefore it is important that the subsea pipeline must be designed to ensure that heat loss is small enough. Heat loss of unburied pipeline is higher than buried pipeline. For that purpose, trenching and backfilling system is a commonly used method for maintaining flow assurance in subsea pipeline installation. For this commonly used method, knowing thermal conductivity of backfill is essential to protect a heat loss of pipeline. This paper presents thermal conductivity of backfill soil using laboratory model test and numerical analysis for various backfill. In conclusion, it can be seen that higher the sand content of the man-made backfill sample, the higher the thermal conductivity. On the other hand, as the water content increases, the thermal conductivity becomes smaller.

Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

  • Lee, Duk-Hang;Han, Won-Yong;Moon, Bong-Kon;Park, Young-Sik;Jeong, Woong-Seob;Park, Kwi-Jong;Lee, Dae-Hee;Pyo, Jeong-Hyun;Kim, Il-Joong;Kim, Min-Gyu;Matsumoto, Toshio
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.305-313
    • /
    • 2012
  • We conducted thermal analyses and cooling tests of the space observation camera (SOC) of the multi-purpose infrared imaging system (MIRIS) to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than $206^{\circ}K$. This is similar to the results of the passive cooling test (${\sim}200.2^{\circ}K$). For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about $160^{\circ}K$ in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below $200^{\circ}K$ with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

Preliminary Results of Thermal Effects due to Mobile Phones

  • Sik, Yoo-Done
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.471-473
    • /
    • 2002
  • Public concerns associated with the electromagnetic field (EMF) exposures from mobile phones on human body are increased. Although studies on the effects of the EMF exposures on human have been carried out for a long time, it is not proved yet whether the EMF effect is harmful or not. Based on the scientific results by experts, EMF exposure limits have been regulated as a precautionary approach on the assumption that the EMF effect may be harmful. It is well known that absorbed EMF can be transformed into heat within biological tissues and that thermal effects are related with the specific absorption rate (SAR) distribution. However, the relative magnitude and distribution of the energies are not well defined. Although there is comprehensive information of the thermal effects, most of them come from animal and in vitro studies. Considerable efforts have been made to analyze the EMF absorption model while the actual temperature in the human body has been rarely measured. Temperature changes on the face of a healthy male volunteer were studied. A digital mobile phone of 1.8GHz was used. A digital infrared imaging system (IRIS-5000, Medicore, Seoul, Korea) was applied to take infrared pictures of the face every minute while the volunteer talked over the mobile phone for 20 minutes. The specification of the imaging system was as follows: Temperature resolution = 0.1$^{\circ}C$; Range of temperature measurement = 17~40$^{\circ}C$; Pixel size = 0.9mm ${\times}$ 0.9mm; Frame time = 2.6s; Active temperature of detector = 77$^{\circ}$K. The result showed that temperature of the ear region was increased during the phone call and the region of the temperature increase on the face was expanded as the phone call time increased. Further study is necessary to investigate the temperature rise analytically and quantitatively.

  • PDF