• 제목/요약/키워드: thermal humidity

검색결과 645건 처리시간 0.03초

Intelligent Microclimate Control System Based on IoT

  • Altayeva, Aigerim Bakatkaliyevna;Omarov, Batyrkhan Sultanovich;Cho, Young Im
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제16권4호
    • /
    • pp.254-261
    • /
    • 2016
  • The present research paper is devoted to solving an urgent problem, i.e., the energy saving and energy efficiency of buildings. A rapid settlement method and experimental control of the energy conservation based on the specific characteristics of the thermal energy consumption for the heating and ventilation of the buildings, and as well as the rapid development of wireless sensor networks, can be used in a variety of monitoring parameters in our daily lives. Today's world has become quite advanced with smart appliances and devices such as laptops, tablets, TVs, and smartphones with various functions, and their use has increased significantly in our day-to-day lives. In this case, the most important role is played by a wireless sensor network with its development and use in heterogeneous areas and in several different contexts. The fields of home automation, process management, and health management systems make extensive use of wireless sensor networks. In this paper, we explore the main factors of the microclimate in an indoor environment. We control the temperature humidity, and other factors remotely using sensors and Internet-of-Things technologies.

실리콘 서브 마운틴 기반의 LED 패키지 재료평가 및 신뢰성 시험 (Reliability Testing and Materials Evaluation of Si Sub-Mount based LED Package)

  • 김영필;고석철
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.1-10
    • /
    • 2015
  • The light emitting diodes(LED) package of new structure is proposed to promote the reliability and lifespan by maximize heat dissipation occurred on the chip. We designed and fabricated the LED packages mixing the advantages of chip on board(COB) based on conventional metal printed circuit board(PCB) and the merits of Si sub-mount using base as a substrate. The proposed LED package samples were selected for the superior efficiency of the material through the sealant properties, chip characteristics, and phosphor properties evaluations. Reliability test was conducted the thermal shock test and flux rate according to the usage time at room temperature, high-temperature operation, high-temperature operation, high-temperature storage, low-temperature storage, high-temperature and high-humidity storage. Reliability test result, the average flux rate was maintained at 97.04% for each items. Thus, the Si sub-mount based LED package is expected to be applicable to high power down-light type LED light sources.

바닥급기 공조시스템(UFAC)을 적용한 작업공간의 실내환경 평가기법 개발연구 (A Study on the Design Prototype Development of Underfloor Air-Conditioning System(UFAC) for Improving Indoor Environment)

  • 정광섭;한화택
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.325-336
    • /
    • 2000
  • During the last decade, an increasing interest in Underfloor Air-Conditioning(UFAC) systems has emerged. The purpose of this paper is to evaluate comprehensively the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. In this paper, the physical measurements and the interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation(POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey.

  • PDF

착상을 고려한 극저온 질소-대기 열교환기의 해석 (Analysis of a Cryogenic Nitrogen-Ambient Air Heat Exchanger Including Frost Formation)

  • 최권일;장호명
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.825-834
    • /
    • 2000
  • A heat exchanger analysis is performed to investigate the heating characteristics of cryogenic nitrogen by ambient air for the purpose of cryogenic automotive propulsion. The heat exchanger is a concentric triple-passage for supercritical nitrogen, and the radial fins are attached on the outermost tube for the crossflow of ambient air. The temperature distribution is calculated for the nitrogen along the passage, including the real gas properties of nitrogen, the fluid convections and the conductions through the tube walls and the fins. Since the wall temperature of the outer (ambient side) tube is very low in most cases, a heavy frost can be formed on the surface, affecting the heat exchange performance. By the method of the similarity between the heat and the mass transfer of moist air, the frost growth and the time-dependent effectiveness of the heat exchanger are calculated for various operating conditions. It is concluded that the frost formation can augment the heating of nitrogen during the initial period because of the latent heat, then gradually degrades the heat exchange because of the increased thermal resistance. Practical design issues are discussed for the flow rate of nitrogen, the velocity and humidity of ambient air, and the sizes of the fin.

  • PDF

태양열 이용 소용량 제습냉방시스템 (Small-Capacity Solar Cooling System by Desiccant Cooling Technology)

  • 이대영;권치호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.154-156
    • /
    • 2008
  • A prototype of the desiccant cooling system with a regenerative evaporative cooler was built and tested for the performance evaluation. The regenerative evaporative cooler is to cool a stream of air using evaporative cooling effect without an inc6rease in the humidity ratio. It is comprised of multiple pairs of dry and wet channels and the evaporation water is supplied only to the wet channels. By redirecting a portion of the air flown out of the dry channel into the wet channel, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature at the outlet end of the dry channels. Incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in the desiccant rotor that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners. At the ARI condition with the regeneration temperature of $60^{\circ}C$, the prototype showed the cooling capacity of 4.4 kW and COP of 0.75.

  • PDF

Effects of Microwaves on the Germination of Weed Seeds

  • Sahin, Hasan
    • Journal of Biosystems Engineering
    • /
    • 제39권4호
    • /
    • pp.304-309
    • /
    • 2014
  • Purpose: Weeds cause significant losses in agricultural production. In this study, we investigated the effect of microwaves on the germination rates of cress and arugula seeds to determine whether microwaves could be developed as an effective alternative to conventional chemical-based herbicides. Methods: Seeds were planted at equal depths (8-10 mm) in a soil-turf mixture, and seeds were exposed to microwaves for 126 s, 70 s, and 50 s in a device constructed specifically for this study. A microwave tunnel was built using a variable speed conveyor belt and 4 magnetrons with a combined output power of 2.8 kW. Seeds that were not exposed to microwaves were germinated with regulated irrigation, temperature, and humidity controls in parallel with the treated seeds, and the germination rates were compared among the treatment groups. Results: We found that the exposure of cress and arugula seeds to microwaves for 126 s inhibited germination close to 100%. Cress seeds treated with microwaves for 50 s showed 95% germination compared to 65% germination of the untreated cress seeds. Conclusions: We predict that the thermal effect of microwave energy affects the germination ratio and germination rate of seeds.

Context Aware Services using Multi-Environmental Sensors and Its application for Ubiquitous Home Networks

  • Quang, Bui Dang;Torregoza, John Paul M.;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제10권6호
    • /
    • pp.786-798
    • /
    • 2007
  • As we go about our daily lives, people often collect surrounding information and adapt to the situation. Computer development trends show that one wants computers to work like human beings, i.e. computers can sense its context and adapt corresponding to context changes. To implement this expectation, a context aware service layer is needed. In this layer, sensors capture its environment and send this information to the service center. Considering received information as its context, the service center seeks the suitable operation according to the context. Tills paper presents a context aware service which is applied in controlling air-conditioner. The air-conditioner includes sensors which are installed at some special positions in a room. Each of these sensors gathers comfort-influenced information like temperature, humidity and sends them to air-conditioner. The air-conditioner adapts its operation to the environment according to the sensed information. To control the air-conditioner effectively, we use a genetic algorithm which is suitable in adaptation issues. The simulation shows that the room condition can be maintained at a comfortable level by using context-aware services in the operation of the air-conditioning system.

  • PDF

Neuro-fuzzy based prediction of the durability of self-consolidating concrete to various sodium sulfate exposure regimes

  • Bassuoni, M.T.;Nehdi, M.L.
    • Computers and Concrete
    • /
    • 제5권6호
    • /
    • pp.573-597
    • /
    • 2008
  • Among artificial intelligence-based computational techniques, adaptive neuro-fuzzy inference systems (ANFIS) are particularly suitable for modelling complex systems with known input-output data sets. Such systems can be efficient in modelling non-linear, complex and ambiguous behaviour of cement-based materials undergoing single, dual or multiple damage factors of different forms (chemical, physical and structural). Due to the well-known complexity of sulfate attack on cement-based materials, the current work investigates the use of ANFIS to model the behaviour of a wide range of self-consolidating concrete (SCC) mixture designs under various high-concentration sodium sulfate exposure regimes including full immersion, wetting-drying, partial immersion, freezing-thawing, and cyclic cold-hot conditions with or without sustained flexural loading. Three ANFIS models have been developed to predict the expansion, reduction in elastic dynamic modulus, and starting time of failure of the tested SCC specimens under the various high-concentration sodium sulfate exposure regimes. A fuzzy inference system was also developed to predict the level of aggression of environmental conditions associated with very severe sodium sulfate attack based on temperature, relative humidity and degree of wetting-drying. The results show that predictions of the ANFIS and fuzzy inference systems were rational and accurate, with errors not exceeding 5%. Sensitivity analyses showed that the trends of results given by the models had good agreement with actual experimental results and with thermal, mineralogical and micro-analytical studies.

화력발전소 배출가스 중 질소산화물의 확산에 관한 연구 (Simulation Study of NOx Dispersion from Power Plant Stack Gas)

  • 박미정;조영민;성두용;김미정;박영구
    • 한국응용과학기술학회지
    • /
    • 제30권3호
    • /
    • pp.540-550
    • /
    • 2013
  • Various efforts have been explored to save the cost in many industrial fields. In order to recover the residual thermal energy from the flue gas, an extreme high efficiency heat exchanger is planning to install at a power plant. The gas temperature will be reduced to $40^{\circ}C$ from $115^{\circ}C$. Thus gas buoyancy decreases, and dispersion of nitrogen oxides is expected to deteriorate as increasing relative humidity. In this study, the conversion of nitrogen monoxide to nitrogen dioxide and dispersion regime are investigated through computational modeling. Nitrogen dioxide which indicates 0.1 ppm at 85 m from the ground could be propagated to 620 m at $115^{\circ}C$ of the flue gas, whilst when cooled down to $40^{\circ}C$, it expands up to 750 m. The ground level influence area showed more expansion of dispersion, approximately to 930 m.

황동이 피복된 코드의 표면 상태가 배합고무와 코드의 접착에 미치는 영향 (The Effect of Surface State of Brass Coated Steel Cord on the Adhesion between Cord and Rubber Compound)

  • 서곤;류민웅;전대진;손봉영
    • 공업화학
    • /
    • 제5권6호
    • /
    • pp.1056-1061
    • /
    • 1994
  • $80^{\circ}C$에서 열처리하거나, $80^{\circ}C$와 상대습도 85%인 습도 조건에서 처리한 황동이 피복된 강선 코드의 표면 상태와 고무와 접착 성질을 조사하였다. 열처리로 황동의 산화가 진행되었으며, 습윤처리 후에는 더 심하게 산화되었다. 처리기간이 길어질수록 전처리한 코드의 접착 성질이 나빠졌으며, 고무부착 정도가 심하게 저하되었다. 황동 피복층의 산화로 인한 코드의 접착 성질 저하를 산화아연층의 과도한 성장과 연계지어 설명하였다.

  • PDF