• Title/Summary/Keyword: thermal history

Search Result 286, Processing Time 0.025 seconds

Ferroelectric P(VDF/TrFE) Copolymers in Low-Cost Non-Volatile Data Storage Applications

  • Prabu A. Anand;Lee, Jong-Soon;Chang You-Min;Kim, Kap-Jin
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.237-237
    • /
    • 2006
  • P(VDF/TrFE(72/28) ultrathin films were used in the fabrication of Metal-Ferroelectric polymer-Metal (MFM) single bit device with special emphasis on uniform film surface, faster dipole switching time under applied external field and longer memory retention time. AFM and FTIR-GIRAS were complementary in analyzing surface crystalline morphology and the resultant change in chain orientation with varying thermal history. DC-EFM technique was used to 'write-read-erase' the data on the memory bit in a much faster time than P-E studies. The results obtained from this study will enable us to have a good understanding of the ferroelectric and piezoelectric behavior of P(VDF/TrFE)(72/28) thin films suitable for high density data storage applications.

  • PDF

Damping Effects of Fluid Viscous Dampers on the Seismic Response of Bridges (교량의 지진응답거동에 작용하는 액체점성감쇠기의 감쇠효과 분석)

  • 정상모;안창모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.379-386
    • /
    • 2001
  • Fluid viscous dampers have been used as energy dissipators or STU's (Shock Transmission Unit) in earthquake resistant designs for bridges. Viscous dampers have many advantages compared to other friction type or visco-elastic type of dampers. They do neither increase internal pier forces due to their out of phase response, nor produce reaction forces at the low velocities associated with thermal movements. Therefore, they anable the super structure to restore itself perfectly after a severe movement dut to seismic excitations. This paper investigates the response of bridges designed with viscous dampers in regard to damping coefficients, properties of dampers, and arrangements of dampers. For this purpose, time-history dynamic analyses have been performed using a very simple model relevant to a typical bridge example. Based on the results, it presents some design duidelines on how to determine a proper damping ratio and on how to arrange dampers. In usual cases, damping coefficients corresponding to about 0.2-0.3 of damping ratios seem to be very effective in bridge designs.

  • PDF

Study on the Flow and Mass Transfer in a PASB Arc Plasma Chamber (PASB 아크 플라즈마 챔버에서 발생하는 유동 및 물질전달에 관한 연구)

  • Lee, Jong-Chul;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.4
    • /
    • pp.7-13
    • /
    • 2008
  • The computational investigation is performed to find out the interaction of arc plasmas with surrounding materials and the thermal flow characteristics in a PASB (Puffer-Assisted Self-Blast) chamber, which is one of new breaking concepts in $SF_6$ switchgears. It is very important to define the flow and mass transfer happened during the full arcing history for further understanding complex physics inside the chamber. In this study, we have considered two diffusion processes by the hot arc plasma, one is PTFE nozzle ablation and the other is Cu electrode evaporation, simultaneously. It was found that the principle of the pressure-rise inside the chamber is confirmed by the computational results and the increase of the electrical conductivity of the residual gas near current zero is critical to the chamber design.

Piping Failure Analysis In Domestic Nuclear Safety Piping System (국내 안전등급 배관에 대한 손상사례 분석)

  • Choi, Sun-Yeong;Choi, Young-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.617-621
    • /
    • 2003
  • The purpose of this paper is to analyze piping failure trend of safety pipings In domestic nuclear power plants. First, database for the piping failure was constructed with 105 data fields. The database includes plant population data, event data, and service history data. 7 kinds of piping failures in domestic NPPs were investigated. Among the 7 cases, detailed root causes were investigated for 3 cases. The first one is pipe wall thinning in main feedwater pipings of Westinghouse 3 loop type plants. The root cause of the wall thinning was flow accelerated corrosion near welding area. The next one is leak event in chemical and volume control system(CVCS) due to vibration. Some cracks occurred in socket welding area. The events showed that the integrity or socket weld is very vulnerable to vibration. The last one is also a leak event in primary sampling line in Korean standard reactor due to thermal fatigue. Although the structural integrity was not maintained by the events, there was no effect on nuclear safety in the above 3 piping failure eases.

  • PDF

Estimation of Hardened Layer Dimensions Using Multi-Point Temperature Monitoring in Laser Surface Hardening Processes (레이저 표면 경화 공정에서 다점 온도 모니터링을 통한 경화층 크기 예측)

  • 우현구
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1048-1054
    • /
    • 2003
  • In laser surface hardening processes, the geometrical parameters such as the depth and the width of a hardened layer can be utilized to assess the hardened layer quality. However, accurate monitoring of the geometrical parameters for on-line process control as well as for on-line quality evaluation is very difficult because the hardened layer is formed beneath a material surface and is not visible. Therefore, temperature monitoring of a point of specimen surface has most frequently been used as a process monitoring method. But, a hardened layer depends on the temperature distribution and the thermal history of a specimen during laser surface hardening processing. So, this paper describes the estimation results of the geometric parameters using multi-point surface temperature monitoring. A series of hardening experiments were performed to find the relationships between the geometric parameters and the measured temperature. Estimation results using a neural network show the enhanced effectiveness of multi-point surface temperature monitoring compared to one-point monitoring.

Experimental Study Mixing, Placing and Hydration Temperature of 1400kg/$\textrm{cm}^2$ Ultra High-Strength Concrete (1400kg/$\textrm{cm}^2$ 초고강도 콘크리트의 배합, 타설 및 수화온도 이력에 관한 연구)

  • 윤영수;장일영;원종필;최응규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.430-435
    • /
    • 1997
  • This paper presents the material properties and production of 1400kg/$\textrm{cm}^2$ ultra high-strength concrete in consideration of the history of hydration temperature for the practical utilization. A series of laboratory tests were conducted to optimize the mix proportion and then the full-scall mock up tests were performed to investigate the practicability. The thermal sensors were installed prior to concrete casting into the walls and columns, to measure the hydration temperature during the hardening process, which is inevitable to select the most appropriate curing scheme.

  • PDF

Effect of Hydration Heat Evolution on Autogenous Shrinkage of High Strength Concrete (초기수화발열이 고강도콘크리트의 자기수축특성에 미치는 영향)

  • 정해문;도변박지;하야도륭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.95-100
    • /
    • 2003
  • The shrinkage of high strength/high performance concrete is very important property for the good working of a structure since it very often generates early age cracking due to thermal and autogenous shrinkage. Autogenous shrinkage occurs as a result of internal moisture depletion due to hydration and temperature-induced effects. The level of autogenous shrinkage occurring due to hydration also depends on temperature history at very early age. It is necessary that effect of temperature on autogenous shrinkage is investigated since the stress generated due to autogenous shrinkage is quantified. In this study, Effect of hydration heat evolution on autogenous shrinkage of high strength concretes with W/C=25-40% was investigated.

  • PDF

Non-linear Temperature Dependent Deformation Analysis of BGA Package Using Moire Interferometry (모아레 간섭계를 이용한 BGA 패키지의 비선형 열변형 해석)

  • Ju Jin Won;Han Bongtae
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.28-32
    • /
    • 2003
  • Thermo-mechanical behavior of a ceramic ball grid array(CBGA) package assembly and wire bond ball grid array(WB-PBGA) package assemblies are characterized by high sensitive moire interferometry. Moire fringe patterns are recorded and analyzed at various temperatures in a temperature cycle. Thermal-history dependent analyses of global and local deformations are presented, and bending deformation(warpage) of the package and shear strain in the rightmost solder ball are discussed. A significant non-linear global behavior is documented due to stress relaxation at high temperature. The locations of the critical solder ball in WB-PBGA package assemblies are documented.

  • PDF

Computer Simulation of Hardenability Characteristics of Alloy Steel for Structural Purposes (컴퓨터 시뮬레이션에 의한 구조용 합금강의 경화능특성 해석)

  • Kim, K.S.;Hong, C.P.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.2
    • /
    • pp.1-10
    • /
    • 1989
  • In this study, the specimens of SCM 22 H steel were quenched in oil and water baths at various agitation conditions in order to investigate the effects of quenchants and agitation conditions on the quench-hardening. A multi-channel temperature measurement apparatus was employed to obtain the cooling curves at several predetermined positions of specimens. Microstructural observation and hardness test were also carried out. Computer simulation of heat treating process was carried out using the modified finite difference method. Prediction of thermal history and hardness distribution by 2-dimensional computer analysis was in good agreement with the experimental results. It was found that the quantitative design of heat treating process can be made by the computer aided heat-treating analysis.

  • PDF

The crystallinity and electrical characteristics of low density polyetylene thin film (저밀도 폴리에틸렌 필림의 결정화도 및 전기적 특성)

  • 윤중락;권정열;이헌용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.164-168
    • /
    • 1996
  • The relation between crystallinity and thermal history in low density polyethylene thin films and their effect on electric conduction phenomena and dielectric breakdown was studied. The low density polythylene thin films obtained by the solution growth method heat-treated at 140[$^{\circ}C$] for 2 h and subsequently cooling to various ways. The degree of crystallinity was estimated by the X-ray diffraction measurement for the specimen of slowly cooling, ICE quenching and liquid nitrogen quenching. The result shows that the crystallinity decreases become faster as the cooling speed increased, and that conduction phenomenon is governed by the space charge limited current in high field. It was found that the dielectric breakdown field increases with an increase in cooling speed and test number in self-healing breakdown method.

  • PDF