• Title/Summary/Keyword: thermal factor

Search Result 1,559, Processing Time 0.03 seconds

Numerical Investigation of Thermal Characteristics and Geometrical Optimization in circular tubes with micro fins (원형 단면관 내 미세 휜의 형상 변화에 따른 열.유동 특성 및 최적 형상 개발에 관한 수치 해석)

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1113-1118
    • /
    • 2006
  • A numerical investigation of single phase heat and flow characteristics in circular tubes with a single set of spiral micro fins was performed with varying geometrical parameters like fin height, spiral angle, and number of fins. The properties of $40^{\circ}C$ water was used as a working fluid to simulate a condenser and the RNG $k-{\epsilon}$ turbulence model was adopted. Calculation results were obtained in fully developed turbulent flow with constant surface heat flux boundary condition. Relative terms were introduced to investigate the substitution effect of conventional smooth tubes. The dimensionless terms were the heat transfer enhancement factor, the pressure drop penalty factor, and the efficiency index. Additionally, a numerical optimization was carried out to maximize thermal performance with the concept of the robust design. A statistical analysis showed that fin height interacts with number of fins and spiral angle.

  • PDF

Effect of Hollow Composite Yarn Characteristics to the Comfort Property of Fabrics for High Emotional Garment (중공 복합사 특성이 고감성 의류용 직물의 쾌적성에 미치는 영향)

  • Kim, Hyun-Ah
    • Science of Emotion and Sensibility
    • /
    • v.17 no.4
    • /
    • pp.71-78
    • /
    • 2014
  • Composite draw textured yarns(DTY) and air jet textured yarns(ATY) with hollow PET filament have been used for making high emotional fabrics including light weight sports wear garments. This study investigated effect of hollow composite yarns and fabric structural parameters to the comfort properties related to the moisture and thermal transport phenomena for the composite fabrics made of DTY and ATY with hollow PET filament. Wicking property of hollow composite fabric was superior at the high pore size fabric and was not influenced by fabric cover factor. Wicking property of the fabric with ATY was better than that of the fabric with DTY. On the other hand, drying rate of fine pore sized fabric was shorter than that of large pore sized fabric and drying rate of high multi yarn fabric with low cover factor and small pore size was superior than that of hollow composite fabric. The pore size of the fabric was dominant factor in the air permeability and thermal conductivity of hollow composite fabric. High pore sized fabric showed high air permeability and thermal conductivity of hollow composite fabric was nonlinearly inversely proportional to pore size of the fabric.

Thermal-mechanical Fatigue Life Prediction of 12Cr Forged Steel Using Strain Range Partitioning method (변형률분할법에 의한 12Cr 단조강의 열피로 수명예측)

  • 하정수;옹장우;고승기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1192-1202
    • /
    • 1994
  • Fatigue behavior and life prediction were presented for thermal-mechanical and isothermal low cycle fatigue of 12Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test at 350 to 600.deg. C and isothermal low cycle fatigue test at 600.deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Cyclic softening behavior was observed regardless of thermal-mechanical and isothermal fatigue tests. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. The difference in fatigue lives was dependent upon the magnitudes of inelastic strain ranges and mean stresses. Increase in inelastic strain range showed a tendency of intergranular cracking and decrease in fatigue life, especially for out-of-phase thermal-mechanical fatigue. Thermal-mechanical fatigue life prediction was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase thermal-mechanical fatigue lives, which was quite improved conservatively by a proposed strain range partitioning method.

A Study on Numerical Analysis of Thermal Stress for an Monolith Ceramic Heat Exchanger (일체형 세라믹 열교환기의 전산 열응력 해석에 관한 연구)

  • Paeng, Jin-Gi;Kim, Ki-Chul;Yoon, Young-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.613-620
    • /
    • 2009
  • The thermal stresses of a ceramic heat exchanger were analyzed numerically since the ceramic material is good in heat resistance but weak in the thermal stress. The analysis of thermal stress was conducted in the ceramic core with two boundary conditions depending on bolt jointing. The thermal stresses were computed by applying temperature and pressure distributions obtained from the numerical results of conjugate heat transfer to ANSYS WORKRBENCH. When number of bolt joining halls was reduced from $8\times2$ to $4\times2$, the maximum principal stresses decrease by 47.6~50.5% and increase in safety factors by 2.18~2.5 for ultimate tensile strength. Thus, it can be said that bolt joining halls should be minimized in ceramic heat exchanger to be efficient in reducing thermal stress. In addition, the width of particular gas flow passages were revised from 52 mm to 42 mm to reduce maximum thermal stresses since certain passages experienced high thermal stresses. From the revision, safety factors were increased by 13.8~14.1% for the boundary condition of $4\times2$ bolt joining halls. Therefore, it is suggested that thermal stress can be reduced by changing local geometry of a ceramic heat exchanger.

Numerical Study on the Thermal Design of Lunar Terrain Imager System Loaded on the Korea Pathfinder Lunar Orbiter (시험용 달 궤도선의 광학탑재체 시스템 열설계에 대한 수치해석적 연구)

  • Kim, Taig Young;Chang, Su-Young;Heo, Haeng-Pal
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.4
    • /
    • pp.309-318
    • /
    • 2019
  • The thermal design of the Lunar Terrain Imager (LUTI) on the Korean Pathfinder Lunar Orbiter (KPLO) was performed and the soundness of the thermal design was verified by thermal analysis. The thermal environment of the lunar mission orbit should be reflected in the thermal design because the IR radiation of the lunar surface is important, unlike the earth orbit. The components or modules exposed to the outside of the satellite are insulated with MLI as much as possible, but the camera tube and the radiator are functionally exposed, so the thermal shield using the concept of radiation shape factor is mounted on the front to mitigate IR radiation. The IR emissivity is important in the front side of the radiator that receives little solar radiation, and components that are susceptible to thermal deformation such as the tube use a radiation heater to minimize the temperature gradient. Through the investigation of computational results, it was confirmed that the thermal design of LUTI is stable in various situations.

Study on Thermal Behavior and Design Method for Coil-type PHC Energy Pile (코일형 PHC 에너지파일의 열적 거동 및 설계법에 관한 연구)

  • Park, Sangwoo;Sohn, Jeong-Rak;Park, Yong-Boo;Ryu, Hyung-Kyou;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.37-51
    • /
    • 2013
  • An energy pile encases heat exchange pipes to exchange thermal energy with the surrounding ground formation by circulating working fluid through the pipes. An energy pile has many advantages in terms of economic feasibility and constructability over conventional Ground Heat Exchangers (GHEXs). In this paper, a coil-type PHC energy pile was constructed in a test bed and its thermal performance was experimentally and numerically evaluated to make a preliminary design. An in-situ thermal response test (TRT) was performed on the coil-type PHC energy pile and its results were compared with the solid cylinder source model presented by Man et al. (2010). In addition, a CFD numerical analysis using FLUNET was carried out to back-analyze the thermal conductivity of the ground formation from the Ttype PHC energy RT result. To study effects of a coil pitch of the coil-type heat exchange pipe, a thermal interference between the heat exchange pipes in PHC energy piles was parametrically studied by performing the CFD numerical analysis, then the effect of the coil pitch on thermal performance and efficiency of heat exchange were evaluated. Finally, an equivalent heat exchange efficiency factor for the coil-type PHC energy pile in comparison with a common multiple U-type PHC energy pile was obtained to facilitate a preliminary design method for the coil-type PHC energy pile by adopting the PILESIM2 program.

Interaction of thermal stress with mechanical stress in circumferentially cracked pipe (원주방향 균열배관에 대한 열하중 및 기계하중의 상호 작용)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.327-332
    • /
    • 2008
  • For the cracked component under combined primary and secondary stress, an interacion between the loads occurs and the secondary stress is relaxed by the primary load. To account for this phenomena, R6 code provides the correction factor which is called V-factor. However, evaluation corrected with V-factor need to be examined for its conservatism. In this paper the conservatism of the current V-factor is examined for the circumferentially cracked pipe under the combined load and new evaluation method is proposed to reduce the conservatism.

  • PDF

A Study on the Asymmetry Factor in Photophoresis (광영동에 있어서의 비대칭인자에 대한 연구)

  • Park, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.694-702
    • /
    • 1995
  • When a small absorbing particle is exposed to a strong thermal radiation incidence, it moves towards or away from the radiation source due to the nonuniform internal absorption of the radiation. It is called the photophoretic phenomena and governed by the asymmetry factor. An asymmetry factor for the total wavelength range is calculated to estimate the photophoretic phenomena of a particle in a combustor or in the atmosphere and compared to that for a single wavelength. The samples are soot particulates, water droplets, ice particles, silicon particles, $SiO_2$ particles, aluminium oxide particles, whose spectral complex refractive index are available. Although differences between total and monochromatic asymmertry factors are not much for relatively uniform distribution of the spectral refractive index, they are great in general. Therefore the use of the monochromatic factor will considerably deteriorate the accuracy of the calculation of the photophoresis.

  • PDF

Thermal Deformation Induced Preload Changein the Tilting Pad Journal Bearing (열변형으로 인한 틸팅패드 저널베어링의 예압 변화)

  • Suh, Junho;Hwang, Cheolho
    • Tribology and Lubricants
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This paper focuses on the thermal deformation induced preload change in the tilting pad journal bearing, using a three-dimensional (3D) thermo-hydro-dynamic (THD) approach. Preload is considered as a critical factor in designing the tilting pad journal bearing. The initial preload measured under nil external load and nil thermal gradient is influenced by two factors, namely, the thermal deformation and elastic deformation. Thermal deformation is due to a temperature distribution in the bearing pads, whereas the elastic deformation is due to fluid forces acting on the pads. This study focuses on the changes induced in preload and film clearance due to thermal deformation. The generalized Reynolds equation is used to evaluate the force of the fluid and the 3D energy equation is used to calculate the temperature of the lubricant. The abovementioned equations are combined by establishing a relationship between viscosity and temperature. The heat transfer within the bearing pads, the lubricant, and the spinning journal is calculated using the heat flux boundary condition. The 3D Finite Element Method (FEM) is used in modeling the (1) heat conduction in the spinning journal and bearing pads, (2) thermal gradient induced thermal distortion of the spinning journal and pads, and (3) viscous shearing, and heat conduction and convection in a thin film. This evaluation method has an increased fidelity, and it can prove to be a cost-effective tool that can be used by designers to predict the dynamic behavior of a bearing.

Influence of Oxidation Inhibitor on Carbon-Carbon Composites : 8. Studies on Thermal Decomposition Mechanism and Thermal Stability of Composites Impregnated with TEOS (산화억제제를 첨가한 탄소/탄소 복합재료의 물성에 관한 연구 : 8. TEOS를 함유한 복합재료의 열분해 메카니즘 및 열안정성 연구)

  • 박수진;서민강;이재락
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.866-875
    • /
    • 2001
  • In this work, thermal decomposition mechanism based on kinetic parameters and thermal stability of carbon fiber-reinforced carbon matrix composites (C/C composites), have been studied under high temperature oxidative conditions with addition of tetra-ethylorthosilicate (TEOS) as an oxidation inhibitor. Thermogravimetric analysis (TGA) was executed to evaluate the thermal decomposition mechanism and thermal stability of C/C composites in the temperature range of 30 ~ $850^{\circ}C$. As a result, the kinetic parameters of the composites impregnated with TEOS, i.e., activation energy for thermal decomposition ($E_d$), order of reaction (n) , and pre-exponential factor (A) were evaluated as 136 kJ/mol, 0, and 2.3$\times$$10^9s^{-1}$, respectively. Especially, the IPDT and $E_d$ of C/C composites impregnated with TEOS were improved largely compared with the composites impregnated without TEOS, due to the formation of $SiO_2$ on composite surfaces, resulting in interrupting the oxygen attack to carbon active site in the composites.

  • PDF