• 제목/요약/키워드: thermal extraction

검색결과 264건 처리시간 0.021초

실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토 (Consideration of Appropriate Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage in an Office Building by Use of Measurement Value)

  • 정재훈
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.719-726
    • /
    • 2010
  • In this paper, the appropriate thermal storage time of an air-conditioning system with slab thermal storage was considered by use of summer measurement values. Two standards of heat extraction rate and criterion function were established as the standard that evaluates appropriateness. When heat extraction rate was a standard, zero hour and seven hours were obtained as appropriate thermal storage time, in the case of evaluation by energy consumption and running cost individually. Also, when criterion function was a standard, the difference between energy consumption and running cost was small, it was because the weight function to room air temperature deviation was much bigger than heat extraction rate.

축열시스템의 온수이용 예측에 관한 연구 (The Study on Prediction of Hot Water Extraction in a Thermal Energy Storage System)

  • 조운;박이동
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.71-80
    • /
    • 1998
  • In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load for demand. Lately, practical use of thermal energy storage system and attention to essential use of energy have been increased. From this point of view, especially, a study about the energy extraction process from a storage tank is necessary. So in this study, useful rate of hot water and hot water extraction efficiency was analysed respect to dynamic and geometric parameters dominating the hot water extraction process.

  • PDF

지중열원 열펌프 시스템의 난방성능 해석 (A Study on the Heating Performance of Ground Source Heat Pump System)

  • 우정선;김대기;이세균
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1175-1182
    • /
    • 2004
  • Installations of vertical boreholes for the ground source heat pump system are expensive to install. One way to reduce the initial cost is to increase the specific heat extraction rate of borehole system. However, as the specific heat extraction rate increases the temperature of borehole fluid decreases with the resultant lower Coefficient Of Performance in Heating(COPH) of heat pump system. The purpose of this study is to provide the basic informations about the performance of heat pump system with the specific heat extraction rate and soil thermal properties such as thermal conductivity and temperature. It is shown that the specific heat extraction rate is the most important parameter for the ground source heat pump system. To obtain the reasonable COPH value (COPH > 3) the heat extraction rate should be about 25 W/m or less. Accurate measurements of soil thermal properties are also very important to design the system properly. The effects of borehole thermal resistances are also examined in this study.

Development of Fast Screening Method for Crop Protection Agents in Tobacco by Stir Bar Sorptive Extraction and Thermal Desorption coupled to GC/MS

  • Min, Hye-Jeong;Lee, Jeong-Min;Shin, Han-Jae;Lee, Moon-Yong;Jang, Gi-Chul
    • 한국연초학회지
    • /
    • 제36권1호
    • /
    • pp.26-33
    • /
    • 2014
  • Simultaneous determination of crop protection agents(CPAs) in food are done with multi-residue methods, which are composed of sample clean-up, concentration, chromatographic separation and detection. Stir Bar Sorptive Extraction(SBSE) technique is used for sample preparation of various analytes in several fields. The aim of this study was to develop a sensitive and fast method based on SBSE followed by thermal desorption - gas chromatography - mass spectrometry(TD - GC/MS) to determine CPAs in tobacco sample. For the analysis of tobacco sample prior to the SBSE method, solvent extraction or ultrasound-assisted solvent extraction was performed. methanol was used as the extraction solvent. The extract was then diluted with water. Finally, the sample was subjected to SBSE. A method for fast screening of crop protection agents in tobacco using SBSE-TD - GC/MS has been developed. About 17 CPAs including organochlorine, organophosphorous and others were identified and quantified. This method showed good linearity and high sensitivity for most of the target CPAs. The method was applied to the determination of CPAs at ng/mL levels in tobacco sample. This method is simple, rapid and may be applied in detection of other components.

슬래브축열의 최적축열시간 산정 : 구배법 알고리즘에 의한 해석 (An Analysis of the Optimal Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage : An Analysis by the Gradient Method Algorithm)

  • 정재훈
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.702-709
    • /
    • 2008
  • In this paper, the optimal thermal storage time of an air-conditioning system with slab thermal storage in office building was analyzed on the basis of the gradient method algorithm. The sum of room temperature deviation and heat extraction rate was set to the criterion function. It was calculated that four hours is the optimal thermal storage time under the standard evaluation criterion. Furthermore, some case studies were executed by controlling ratio of weight functions of room temperature deviation and heat extraction rate in criterion function. It is possible to design many kinds of optimal operation of an air-conditioning system with slab thermal storage by controlling ratio of the weight functions in criterion function.

HBT의 전류원 모델을 위한 최적 열 저항값 추출 방법 (Optimal Thermal Resistance Extraction Method for the Current Source Model of HBT)

  • 서영석;김인성;송재성;남효덕
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.367-372
    • /
    • 2004
  • Two new extraction methods for the thermal Resistance of HBT(Heterojunction Bipolar Transistors) are proposed. First, the analytical expression, based on the thermal characteristics that the base to emitter junction voltage drops with the increase of junction temperature, is derived. Second, the thermal resistance equation that can predict the measured DC(Direct Current) data optimally is derived. These optimal thermal resistance expression is applied to the 2 finger 2${\times}$20${\mu}{\textrm}{m}$-AlGaAs/GaAs HBT and shows the good agreement with the measured data.

천연식용색소 개발을 위한 치자에서 황색소의 추출 (Yellow Color Extraction from Gardenia jasmonoides Ellis for Development of Natural Food Color)

  • 김희구;손홍주
    • 한국식품영양학회지
    • /
    • 제10권2호
    • /
    • pp.241-245
    • /
    • 1997
  • 천연식용색소를 제조하기 위하여 치자를 이용하여 색소추출의 최적조건과 황색 4호와의 내열성 및 내광성을 조사하였다. 에탄올을 추출용매로 사용한 경우 색소추출 최적조건은 추출온도 4$0^{\circ}C$, 추출시간 42시간, 추출 pH 7.0 및 기질농도 10%였다. 물추출의 경우 추출온도는 7$0^{\circ}C$, 추출시간 48시간, 추출 pH 7.0 및 기질농도 10%였다. 최적조건에서의 추출수율은 에탄올의 경우 75%였고, 물추출의 경우는 63%로 나타났다. 황색 4호와 치자 황색소의 내열성 및 내광성을 비교 검토한 결과, 황색 4호는 내열성과 내광성이 모두 98% 이상으로 나타났으나, 치자 황색소의 경우는 내열성은 62%, 내광성은 90%로 나타났다.

  • PDF

선택적 히스토그램 빈 기반 열화상 영상 전경 추출 (Foreground Extraction in Thermal Videos Based on Selective Histogram Bins)

  • 유광현;자히르;김진영;신도성
    • 디지털콘텐츠학회 논문지
    • /
    • 제19권4호
    • /
    • pp.757-770
    • /
    • 2018
  • 열화상 영상기반 감시 시스템에서 전경추출은 매우 중요한 단계이다. 전경추출단계는 계산시간과 메모리 사용측면에서 시스템의 실시간 처리가 매우 효율적이어야 한다. 그러나 이러한 효율성은 ROI 탐지의 정확도와 매우 연관되어 있다. 본 논문에서 열화상 비디오 처리를 위하여 새로운 히스토그램 빈에 기반하여 배경과 전경을 분리하기 위한 두 가지 방법을 제시하는데, 이는 임의의 주어진 환경에서 열화상영상의 시간상에서 일관성을 갖는 다는 점과, 이러한 성질이, 간단한 시간축 메디안 필터링에 비하여 80%이상의 메모리를 절감할 수 있다.

A Study of 3D Design Data Extraction for Thermal Forming Information

  • Kim, Jung;Park, Jung-Seo;Jo, Ye-Hyan;Shin, Jong-Gye;Kim, Won-Don;Ko, Kwang-Hee
    • Journal of Ship and Ocean Technology
    • /
    • 제12권3호
    • /
    • pp.1-13
    • /
    • 2008
  • In shipbuilding, diverse manufacturing techniques for automation have been developed and used in practice. Among them, however, the hull forming automation is the one that has not been of major concern compared with others such as welding and cutting. The basis of the development of this process is to find out how to extract thermal forming information. There exist various methods to obtain such information and the 3D design shape that needs to be formed should be extracted first for getting the necessary thermal forming information. Except well-established shipyards which operate 3D design systems, most of the shipyards only rely on 2.5D design systems and do not have an easy way to obtain 3D surface design data. So in this study, various shipbuilding design systems used by shipyards are investigated and a 3D design surface data extraction method is proposed from those design systems. Then an example is presented to show the extraction of real 3D surface data using the proposed method and computation of thermal forming information using the data.

온수 추출과정 동안 축열조 내의 열성층 특성 및 온수 이용률에 관한 연구 (A Study on Thermal Stratification Characteristics and Useful Rate of Hot Water in Thermal Storage Tank during Hot Water Extraction Process)

  • 장영근;박정원
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.503-511
    • /
    • 2002
  • Heat flow characteristics during hot water extraction process was studied experimentally. Data were taken at various outlet port type for the fixed inlet port type, inlet-outlet temperature differences and mass flow rates. In this study, the temperature distribution in a storage tank and an outlet temperature were measured to predict a degree of stratification in the storage tank, and a useful rate of hot water was analysed with respect to the variables dominating a extraction process. Experimental results show that the degree of stratification and useful rate of hot water are all high in a low flow rate in case of using modified distributor I (MDI) as the outlet port type.