• 제목/요약/키워드: thermal environment

검색결과 2,978건 처리시간 0.029초

Studies on magneto-electro-elastic cantilever beam under thermal environment

  • Kondaiah, P.;Shankar, K.;Ganesan, N.
    • Coupled systems mechanics
    • /
    • 제1권2호
    • /
    • pp.205-217
    • /
    • 2012
  • A smart beam made of magneto-electro-elastic (MEE) material having piezoelectric phase and piezomagnetic phase, shows the coupling between magnetic, electric, thermal and mechanical under thermal environment. Product properties such as pyroelectric and pyromagnetic are generated in this MEE material under thermal environment. Recently studies have been published on the product properties (pyroelectric and pyromagnetic) for magneto-electro-thermo-elastic smart composite. Hence, the magneto-electro-elastic beam with different volume fractions, investigated under uniform temperature rise is the main aim of this paper, to study the influence of product properties on clamped-free boundary condition, using finite element procedures. The finite element beam is modeled using eight node 3D brick element with five nodal degrees of freedom viz. displacements in the x, y and z directions and electric and magnetic potentials. It is found that a significant increase in electric potential observed at volume fraction of $BaTiO_3$, $v_f$ = 0.2 due to pyroelectric effect. In-contrast, the displacements and stresses are not much affected.

대공간내 인체발열 미고려시의 하계 온열환경 조사 (A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.3-8
    • /
    • 2008
  • 본 연구에서는 기존 대공간의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인하여, 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 기초데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하계 대공간의 실내온열환경 실측실험을 실시하여 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 하계 실내온열환경을 포괄적으로 검토하였다.

  • PDF

다중 온도 모니터링을 통한 충적층 및 하상의 지열특성 평가 연구 (A Study on Geothermal Evaluation of Alluvium and Riverbed using Thermal Line Temperature Monitoring)

  • 정우성;김형수;박동순;안영섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2006
  • In advanced countries, state-of-the-art temperature monitoring technique is widely used for effective use of geothermal resources. But these kind of modern tools such as Thermal Line Sensor has not been applied to find geothermal characteristics of alluvium and riverbed in domestic area. In this research, state-of-the-art thermal line temperature sensor monitoring was introduced. And long term field test using this type of sensor was performed to find geothermal characteristics of alluvium and riverbed and evaluate the availability for heat energy source. As a result, temperature monitoring technique through thermal line sensor was very effective to obtain basic geothermal information of alluvium deposit and riverbed. Also, it was found that the groundwater temperature phase showed its potential of utilization as a energy source of heat pump. It is estimated that further study shows a specific corelation between temperature monitoring data and its availability as a energy source.

  • PDF

대규모 실내경기장의 하계 온열환경 특성 실측조사 - 인체부하 미고려 조건 - (A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Summer - Without Cooling Loads from Occupancy -)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회논문집
    • /
    • 제7권6호
    • /
    • pp.91-101
    • /
    • 2007
  • 본 연구에서는 기존 대규모 실내경기장의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인함으로서 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하절기 대공간의 실내온열환경 실측실험을 비냉방시와 냉방시로 구분하여 실시하였으며 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 실내온열환경을 포괄적으로 검토하였다.

  • PDF

충남지역 농촌 주거용 건물의 열쾌적성능에 관한 연구 (The Study on the Thermal Comfort of Rural Housing in Chung-nam area)

  • 박재상;윤종호;박재완;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.202-207
    • /
    • 2011
  • This study has measured indoor temperature and relative humidity and evaluated it for one year by selecting Chungnam's rural areas for improving indoor environment of rural housing in the circumstance that the environment of housing is poor due to deterioration of rural housing. As a result of its evaluation, the indoor temperature difference by household appeared to be more than $13^{\circ}C$, and it was measured that the indoor temperature was mostly low. A difference of more than 40% in case of relative humidity occurred, so the difference of the indoor environment by household was clear. In case of the thermal comfort zone, the number of households that are distributed to more than 50% of a thermal comfort criterion in the winter was only 3 households, rather than the summer.

  • PDF

확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구 (A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment)

  • 윤종호;안영섭;김병수
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

Nonlinear free vibration analysis of functionally graded carbon nanotube reinforced fluid-conveying pipe in thermal environment

  • Xu, Chen;Jing-Lei, Zhao;Gui-Lin, She;Yan, Jing;Hua-Yan, Pu;Jun, Luo
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.641-652
    • /
    • 2022
  • Fluid-conveying tubes are widely used to transport oil and natural gas in industries. As an advanced composite material, functionally graded carbon nanotube-reinforced composites (FG-CNTRC) have great potential to empower the industry. However, nonlinear free vibration of the FG-CNTRC fluid-conveying pipe has not been attempted in thermal environment. In this paper, the nonlinear free vibration characteristic of functionally graded nanocomposite fluid-conveying pipe reinforced by single-walled carbon nanotubes (SWNTs) in thermal environment is investigated. The SWCNTs gradient distributed in the thickness direction of the pipe forms different reinforcement patterns. The material properties of the FG-CNTRC are estimated by rule of mixture. A higher-order shear deformation theory and Hamilton's variational principle are employed to derive the motion equations incorporating the thermal and fluid effects. A two-step perturbation method is implemented to obtain the closed-form asymptotic solutions for these nonlinear partial differential equations. The nonlinear frequencies under several reinforcement patterns are presented and discussed. We conduct a series of studies aimed at revealing the effects of the flow velocity, the environment temperature, the inner-outer diameter ratio, and the carbon nanotube volume fraction on the nature frequency.

Landsat-8을 활용한 대구시 열 환경구조 분석 (Aanalysis the Structure of Heat Environment in Daegu Using Landsat-8)

  • 김준현;최진호
    • 한국측량학회지
    • /
    • 제32권4_1호
    • /
    • pp.327-333
    • /
    • 2014
  • 도시 열 환경 개선을 위해서는 무엇보다도 특정지역의 열 환경에 대한 구조적 특성분석이 선행되어져 문제점을 분석하고 보완되어야 한다. 본 연구에서는 Landsat 위성을 활용하여 대구광역시의 1월과 8월의 열 환경의 중심성 측정, 분포도 작성, 공간통계 분석 등을 활용하여 공간적 특성에 따른 열 환경구조를 분석하였다. 분석을 위해 위성영상의 열적외밴드를 활용하여 표준정규분포화하여 점수로 중심성을 추출하였고, 국지적 공간에서의 자기 상관성을 파악하기 위한 국지적 모란지수(Local Local Moran's I)를 기초로 한 Cluster Map를 작성하여 환경공간구조의 분포 특성을 파악하였다. 따라서 위성영상을 활용한 열 환경 분포 특성과 중심지의 파악은 도시의 열 환경 개선 계획 및 관리방안을 모색하는데 필요한 중요한 기초자료로서 정부의 다양한 열환경 정책이나 계획에 우선시 되어야 할 참고자료를 제공하고자 한다.

저궤도위성 광학탑재체의 지상 열진공 시험을 위한 예비 열해석 (Preliminary Thermal Analysis for LEO Satellite Optical Payload's Thermal Vacuum Test)

  • 이종률;허환일;김상호;장수영;이덕규;이승훈;최해진
    • 한국항공우주학회지
    • /
    • 제39권5호
    • /
    • pp.466-473
    • /
    • 2011
  • 인공위성의 열제어는 인공위성이 운용궤도상에서 겪는 고진공, 극한의 온도변화 환경에서 위성 구성품의 온도변화를 허용한계 온도 범위 내에서 유지하는데 목적이 있다. 본 연구에서는 저궤도 관측위성(LEO)의 광학탑재체에 대한 열해석 과정으로 열진공 시험 조건, 열진공 챔버의 형상, 위성 탑재체 내부의 열적 환경을 고려하여 열해석 모델을 구성하고 궤도 조건에 따른 열해석을 수행하였다. 또한 광학탑재체의 지상 열진공 시험 조건에 따른 열해석 수행하여 열진공 시험을 위한 시험조건을 정립하였다.

소음이 실내 온열감과 온열쾌적감에 미치는 영향 (Effects of Noise on Indoor Thermal Sensation and Comfort)

  • 양원영
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.83-89
    • /
    • 2017
  • Purpose: Thermal sensation or thermal comfort was randomly used in many studies which focused on combined effects of thermal and acoustic environments on human perception. However, thermal sensation and thermal comfort are not synonyms. Thermal comfort is more complex human perception on thermal environment than thermal sensation. This study aims to investigate effects of noise on thermal sensation and thermal comfort separately, and also to investigate effects of temperature on acoustic sensation and comfort. Method: Combined thermal and acoustic configurations were simulated in an indoor environmental chamber. Twenty four participants were exposed to two types of noise (fan and babble) with two noise levels (45 dBA and 60 dBA) for an hour in each thermal condition of PMV-1.53, 0.03, 1.53, 1.83, respectively. Temperature sensation, temperature preference, thermal comfort, noisiness, loudness, annoyance, acoustic comfort, indoor environmental comfort were evaluated in each combined environmental condition. Result: Noise did not affected thermal sensation, but thermal comfort significantly. Temperature had an effect on acoustic comfort significantly, but no effect on noisiness and loudness in overall data analysis. More explicit interactions between thermal condition and noise perception showed only with the noise level of 60 dBA. Impacts of both thermal comfort and acoustic comfort on the indoor environmental comfort were analyzed. In adverse thermal environments, thermal comfort had more impact than acoustic comfort on indoor environmental comfort, and in neutral thermal environments, acoustic comfort had more important than thermal comfort.