• Title/Summary/Keyword: thermal efficiency

Search Result 3,011, Processing Time 0.03 seconds

A Study of Photo-electric Efficiency Improvement using Ultrasonic and Thermal Treatment on Photo-electrode of DSC (염료감응형 태양전지 광전극의 초음파 열처리를 통한 광전효율 개선에 관한 연구)

  • Kim, Hee-Je;Kim, Yong-Chul;Choi, Jin-Young;Kim, Ho-Sung;Lee, Dong-Gil;Hong, Ji-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.803-807
    • /
    • 2008
  • A making process of DSC(dye sensitized solar cell) was presented. In general, Photo electrodes of DSC was made by using colloid paste of nano $TiO_2$ and processing of Doctor-blade printing and high temperature sintering for porous structure. These methods lead to cracks on $TiO_2$ surface and ununiform of $TiO_2$ thickness. This phenomenon is one factor that makes low efficiency to cells. After $TiO_2$ printing on TCO glass, a physical vibration was adapted for reducing ununiform of $TiO_2$ thickness. And a thermal treatment at low temperature(under $75^{\circ}C$) was adapted for reducing cracks on $TiO_2$ surface. In this paper, we have designed and manufactured an ultrasonic circuit (100W, frequency and duty variable) and a thermal equipment. Then, we have optimized forcing time, frequency and duty of ultrasonic irradiation and thermal heating for surface treatment of photo-electrode of DSC. In I-V characteristic test of DSC, ultrasonic and thermal treated DSC shows 19% improved its efficiency against monolithic DSC. And it shows stability of light-harvesting from drastically change of light irradiation test.

The Experiment on The Efficiency of Heating System for Improving Farm Houses (농촌주택 개량을 위한 난방 효율 시험)

  • 이회만;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3395-3409
    • /
    • 1974
  • The purpose of this study is to test and compare the efficiency of heating-system for materials and construction of the wall, ceiling and window in soil brick house, cement house and boulder house respectively, in order to construct ideal farm houses in rural area. The results obtained were as follows: 1. In heat conservation due to construction of walls the thermal efficiency of cement brick house was equivalent to 66.3% of that of soil brick house, and boulder house 60.3% 2. In the case of ceiling, the thermal efficiency of paper ceiling was amounted to 84.2% of that of the composite ceiling (thickness 6mm veneer+thickness. l0m chaffs), and the common ceiling putting on soil above the ceiling, 76% of the composite while the efficiency of the ceiling putting on chaffs above them was 15.8% higher than that of the paper. 3. In the case of improving the window, the double type was 12% higher than. the efficiency of single type. 4. The warming velocity of conventional house was slower but the velocity of radiation was quicker than that of experimental one. It was thought to be due to unscietific constructions of the room bottom, fire inlet and chimney, 5. The temperature gradient line was not dependad upon the amount of throwing into fuel in the rural farm house. 6. It was concluded that the final thermal efficiency of the conventional farm house was 10.6% lower than that of experimental farm house.

  • PDF

Development of Thermal Storage System in Plastic Greenhouse(II) -Thermal performance of solar greenhouse system for hydroponic culture- (플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템의 개발(開發)에 관(關)한 연구(硏究)(II) -수경재배용(水耕栽培用) 태양열(太陽熱) 온실(溫室) 시스템의 열적(熱的) 성능(性能)-)

  • Kim, Y.H.;Koh, H.K.;Kim, M.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.123-133
    • /
    • 1990
  • Thermal performance of a solar heating plastic greenhouse designed for a hydroponic system was studied. The system was constructed with the air-water heat exchanger and thermal storage tank that were combined with hydroponic water beds. Experiments were carried out to investigate the daily average heat stored and released in thermal storage tank, average solar energy collection efficiency, average coefficient of performance, average oil reduction factor of thermal storage system, and the heat transfer coefficient during the nighttime in plastic greenhouse. The results obtained in the present study are summarized as follows. 1. Daily average heat stored in thermal storage tank and released from the thermal storage tank was 1,259 and $797KJ/m^2$ day, respectively. 2. The average solar energy collection efficiency of thermal storage tank was 0.125 during the experiment period. And the average coefficient of performance of thermal storage system in plastic greenhouse was 3.6. 3. The average oil reduction factor of thermal storage system and the heat transfer coefficient during the nighttime in plastic greenhouse were found to be 0.52 and $4.3W/m^2\;hr\;^{\circ}C$, respectively.

  • PDF

A Study on the Textile for Protective Clothing of Fire Fighters (한국 소방대원 방수피복의 소재특성에 관한 비교 연구)

  • 정정숙;이연순
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.5
    • /
    • pp.15-24
    • /
    • 2002
  • The following research conclusions were made, relative to the experiments of the textiles of fire fighters Protective Clothing. 1. When the body protection efficiency such as the thickness, the strength and heat resistance are considered, Nomex(N) is tuned out the best outer shelf, Gore-tex(KG) the best moisture barrier, and Wool-felt(WC) the best thermal barrier. 2. In the hygienic and sanitary efficiency also, N is turned out the best outer shelf, KG the best moisture barrier, and WC the best thermal barrier in its degree of water resistance, water vapour permeability, and air permeability. 3. In the washing and maintenance efficiency, too. N is turned out the best outer shell, KG the best moisture barrier, and WC the best thermal barrier, being considered the material's rate of contraction, the changing rate of frame resistance, water resistance, and water vapour permeability. 4. When considered the frame resistance against the reflection tape and reflection efficiency, O is the best material for it marks the highest score in the frame resistance and reflective effect.

The Effect of Hydrogen Enrichment on Exhaust Emissions and Thermal Efficiency in a LPG fuelled Engine

  • Park, Gyeung-Ho;Han, Sung-Bin;Chung, Yon-Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.8
    • /
    • pp.1196-1202
    • /
    • 2003
  • The concept of hydrogen enriched LPG fuelled engine can be essentially characterized as low emissions and reduction of backfire for hydrogen engine. The purpose of study is obtaining low-emission and high-efficiency in LPG engine with hydrogen enrichment. In order to determine the ideal compression ratio, a variable compression ratio single cylinder engine was developed. The objective of this paper is to clarify the effects of hydrogen enriched LPG fuelled engine on exhaust emission, thermal efficiency and performance. The compression ratio of 8 was selected to minimize abnormal combustion. To maintain equal heating value, the amount of LPG was decreased, and hydrogen was gradually added. In a similar manner, the relative air-fuel ratio was increased from 0.8 to 1.3 in increment of 0.1, and the ignition timing was controlled to be at MBT each case.

Prediction of the Thermal Efficiency at Increased Pressure Ratio in an F-Class Gas Turbine with Operating Data (F급 가스터빈의 압력비 증가 시 운전데이터를 이용한 열효율 변동 예측)

  • Park, Joon-Chul;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Yoo, Ho-sun;Lee, Jae Heon
    • Plant Journal
    • /
    • v.10 no.3
    • /
    • pp.39-44
    • /
    • 2014
  • The gas turbine thermal efficiency has been predicted when the compressor pressure ratio increases from the previously set 13.5. Thermal efficiency has been predicted from 14.2 up to 18.2 at which the turbine work reaches its maximum value on the assumption that isentropic efficiency of the compressor and the turbine are constant using the operating data at the pressure ratio of 13.5. 35.11% of thermal efficiency has been acquired by the performance test when the pressure ratio increased to 16.2 since replacing the compressor low pressure stages. It's been approved that predicting thermal efficiency using the operating data at the pressure ratio of 13.5 is useful within 7.86% of tolerance as the figure measured by the performance test.

  • PDF

Thermal decomposition of urea solution at low temperature in a lab-scaled exhaust pipe (실험실 규모 배기관에서 요소수의 저온 열분해)

  • Ku, Kunwoo;Park, Hongmin;Park, Hyungsun;Kim, Taehun;Hong, Junggoo
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.235-236
    • /
    • 2014
  • An experimental study has been carried out to investigate a thermal decomposition of urea solution at relative low temperature with a lab-scaled exhaust pipe. The conversion efficiency of reductant considered with both ammonia and HNCO related with the urea injection quantity, inflow gas velocity and temperature. The conversion efficiency of ammonia was larger than that of HNCO under all experimental conditions unlike the theoretical thermolysis reaction.

  • PDF

Experimental Study on the Direct Contact Thermal Screw Drying of Sawdust for Wood-Pellet Fuel

  • Lee, Hyoung-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.23-28
    • /
    • 2007
  • Wood fuel must be dried before combustion to minimize the energy loss. Sawdust of Japanese red pine was dried in a direct contact thermal screw dryer to investigate the drying characteristics of sawdust as a raw material for bio-fuel. Average drying rate and energy efficiency was 1.4%/min and 69.23% at $100^{\circ}C$, respectively, and those at $120^{\circ}C$ was 2.1%/min and 71.03%, respectively.

The Effects of Parka on Subject Wear Sensation as to Thermal Resistance (파카의 보온성에 따른 착용감에 관한 연구)

  • Lee Yoon-Jung;Lee Soon-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.3 s.31
    • /
    • pp.295-303
    • /
    • 1989
  • This study is to measure the thermal resistance of 7 types of Parka of different materials with thermal manikin and to compare their effects on physiological responses & subjective wear sensations. Following are the results obtained from the experiments 1) From the thermal manikin experiment, i) As an outer layer, although not significant, water proof fabric was warmer than water proof-vapor permeable fabric. ii) In case of insulating material, down was better for thermal resistance than polyester wadding of the same thickness. Moreover, as the down was thicker, it had more efficiency in thermal resistance. However, the marginal efficiency of thickness was found to be decreasing. 2) From the male-subject experiments, i) Chest temperature, mean skin temperature & microclimate temperature showed the same results on thermal resistance as those of the thermal manikin experiment. ii) Only during rest periods, there was a significant difference among 5 insulating materials in the sense of microclimate humidity. The almost same conclusion was obtained from the above experiments. Even the outer layer did not significantly affect thermal resistance & subjective wear sensation, insulating materials had a significant influence upon them. But in case of 3.5 cm down, it gave less comfortable than that of the thinner. Therefore the optional one for the best comfort & thermal resistance among 7 combinatins is the outer layer of water proff-vapor permeable & insulating material of 2.1 cm down.

  • PDF

Experimental Study on the Operating Characteristics of the Organic Rankine Cycle (ORC 시스템의 운전 특성에 관한 실험연구)

  • Eom, Hong Sun;Yoon, Cheon Seog;Kim, Young Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.208-215
    • /
    • 2013
  • An experimental study of an ORC (Organic Rankine Cycle) system has been performed for small-scale applications in the range of a few kW for low-grade-recovery heat sources. The ORC system was equipped with a scroll expander. Experimental tests were carried out using this system, and showed good performance and reliability for the small-scale system. The effects of various operating conditions were selected as the main parameters for the performance of ORC system, such as the expander speeds and mass flow rates of R-134a for expander inlet temperatures ranging from $100^{\circ}C$ to $190^{\circ}C$, as well as the thermal power, thermal efficiency, expansion efficiency, and volumetric efficiency.