• 제목/요약/키워드: thermal dynamics

검색결과 706건 처리시간 0.03초

Numerical Study of Ablation Phenomena of Flame Deflector

  • Lee, Wonseok;Yang, Yeongrok;Shin, Sangmok;Shin, Jaecheol
    • 항공우주시스템공학회지
    • /
    • 제15권6호
    • /
    • pp.10-18
    • /
    • 2021
  • A flame deflector prevents a launch system from thermal damage by deflecting the exhaust flame of the launch vehicle. During the deflection of the flame, the flame deflector is subjected to a high-temperature and high-pressure flow, which results in thermal ablation damage at the surface. Predicting this ablation damage is an essential requirement to ensure a reliable design. This paper introduces a numerical method for predicting the ablation damage phenomena based on a one-way fluid-structure interaction (FSI) analysis. In the proposed procedure, the temperature and convective heat transfer coefficient of the exhaust flame are calculated using a fluid dynamics analysis, and then the ablation is calculated using a finite element analysis (FEA) based on the user-subroutine UMESHMOTION and Arbitrary Lagrangian-Eulerian (ALE) adaptive mesh technique in ABAQUS. The result of such an analysis was verified by comparison to the ablation test result for a flame deflector.

단순액체의 층밀리기 흐름에 대한 비평형 분자동력학 계산에서 공제방법의 효과 (The efficiency of subtraction technique in a nonequilibrium molecular dynamics simulation of a simple liquid shear flow)

  • 안성청
    • 한국시뮬레이션학회논문지
    • /
    • 제6권1호
    • /
    • pp.53-60
    • /
    • 1997
  • Results from a nonequilibrium molecular dynamics (NEMD) simulation are presented for an argon liquid subject to a shear flow. The segmented molecular dynamics method and the subtraction technique used in NEMD program to reduce the thermal fluctuation noise in data are studied with different shear rates. The standard deviation in the shear stress reduced from 0.030 to 0.004 by the segmented molecular dynamics method for 50 repeated segments. On the other hand, the standard deviation of the data remained the same when the subtraction technique was applied, where as the results of shear stress by constant value in a random way.

  • PDF

해양플랜트 사무공간의 공조 쾌적성 평가에 관한 연구 (The Study for Evaluation of thermal comfort in office on offshore)

  • 임홍석;김판중
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.67-72
    • /
    • 2017
  • This paper presents on the evaluation of thermal comfort in office on offshore. In living quarter of offshore, strict air conditioning performance is required to office on offshore and displacement ventilation is applied to office space which rooms are required to confirm the thermal environment. The computational fluid dynamics (CFD) is performed to calculate the temperature, air velocity in office and thermal comfort such as PPM & PPD is evaluated by the CFD result.

  • PDF

기차 승객의 온열 쾌적성에 관한 수치해석 (Numerical Study on Human Thermal Comfort in a Passenger Train)

  • 김만희
    • 한국자동차공학회논문집
    • /
    • 제24권1호
    • /
    • pp.82-89
    • /
    • 2016
  • This paper presents computational fluid dynamics (CFD) analysis on passenger thermal comfort in a train. Human thermal comfort in vehicles depends mainly on air temperature, mean radiant temperature, air velocity, humidity, and direct solar flux, as well as the level of activity and thermal properties of clothing and seat. The velocity and temperature distribution in a train with and without passengers are reported. The thermal comfort in a passenger train are also presented based on PMV and PPD indices with 16 segments of the human body.

자동차 브레이크 제동시 디스크의 열적거동 및 응력 특성에 관한 연구 (A Study on Thermal Behavior and Stress Characteristics of Discs under Braking Conditions for Automobiles)

  • 백일현
    • Tribology and Lubricants
    • /
    • 제28권5호
    • /
    • pp.246-251
    • /
    • 2012
  • Disc brakes and brake linings are part of the braking system in automobiles; this system works due to the braking power between the disc and pad. Vehicle braking systems have complex environments due to the geometry of the disk and pad, the material properties, the braking conditions, etc. Braking energy is converted into thermal energy during the braking process, due to the frictional heat between the disc brake and pad. This heat is changed to a heat flux, which affects the thermal stress of the disc. The purpose of this study was to use the fluid dynamics software ANSYS CFX to investigate the inner flow characteristics of the air and the heat transfer of the disc, and to analyze the effects on the thermal stress of the disc brake.

차세대전동차의 실내온열환경 연구 (Study on Indoor Thermal Comfort of Advanced EMU)

  • 권순박;박덕신;조영민;박성혁;오세찬;김영남
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1799-1802
    • /
    • 2008
  • More than 7 million people use the Seoul metropolitan subway network daily. This number tends to increase due to the increase of oil price. Indoor air quality of electrical multiple unit (EMU) is strongly affected by outdoor air quality, however, indoor thermal comfort is subjected to heating, ventilating, and air conditioning (HVAC) system of EMU. In general, air temperature, humidity, air velocity, surface temperature, and illumination are key parameters affecting thermal comfort of passenger. It is known that the well-designed HVAC system should improve the thermal comfort of passengers and should increase the energy efficiency of HVAC system also. In this study, we analyzed the thermal comfort of advanced EMU developed by Korea Railroad Research Institute by using the computational fluid dynamics (CFD) in order to find the optimum HVAC system which can improve thermal comfort of passengers with a minimal energy use.

  • PDF

STABILITY OF THE TWO-TEMPERATURE ACCRETION DISK

  • PARK MYEONG-GU
    • 천문학회지
    • /
    • 제28권1호
    • /
    • pp.97-107
    • /
    • 1995
  • The stability of the geometrically thin, two-temperature hot accretion disk is studied. The general criterion for thermal instability is derived from the linear local analyses, allowing for advective cooling and dynamics in the vertical direction. Specifically, classic unsaturated Comptonization disk is analysed in detail. We find five eigen-modes: (1) Heating mode grows in thermal time scale, $(5/3)({\alpha}{\omega})^{-1}$, where alpha is the viscosity parameter and w the Keplerian frequency. (2) Cooling mode decays in time scale, $(2/5)(T_e/T_i)({\alpha}{\omega})^{-1}$, where $T_e\;and\;T_i$ are the electron and ion temperatures, respectively. (3) Lightman-Eardley viscous mode decays in time scale, $(4/3)(\Lambda/H)^2({\alpha}{\omega})^{-1}$, where $\Lambda$ is the wavelength of the perturbation and H the unperturbed disk height. (4) Two vertically oscillating modes oscillate in Keplerian time scale, $(3/8)^{1/2}\omega^{-1}$ with growth rate $\propto\;(H/\Lambda)^2$. The inclusion of dynamics in the vertical direction does not affect the thermal instability, adding only the oscillatory modes which gradually grow for short wavelength modes. Also, the advective cooling is not strong enough to suppress the growth of heating modes, at least for geometrically thin disk. Non-linear development of the perturbation is followed for simple unsaturated Compton disk: depending on the initial proton temperature perturbation, the disk can evolve to decoupled state with hot protons and cool electrons, or to one-temperature state with very cool protons and electrons.

  • PDF

창호일체형 환기시스템 및 중앙냉방시스템 연계 운영에 대한 수치해석적 연구 (Numerical Analysis on the Coupled Operation of Ventilation Window System and Central Cooling System)

  • 박동윤;장성주
    • 한국대기환경학회지
    • /
    • 제31권4호
    • /
    • pp.385-395
    • /
    • 2015
  • This study evaluated indoor environmental characteristics in an office room equipped both with ventilation window system and central cooling system. Fresh air is supplied only by the central cooling system whereas indoor air is discharged outside through both ceiling diffuser and a ventilation window system. Numerical study is conducted by changing the volumetric flow rates of exhaust ports of each system. For estimating the performance of this coupled system, $CO_2$ concentration and Predicted Mean Vote (PMV) were calculated using Computational Fluid Dynamics (CFD) simulation. The more the ceiling diffuser exhausts indoor air, the more the $CO_2$ concentration decreases. However, when the ventilation window system exhausts more indoor air, thermal comfort level gets improved in the office room with cooling system. Therefore, when the ventilation window system is operated, the coupled operation with central cooling system should be considered for enhancing indoor air quality and thermal comfort, together.

Susceptor design by numerical analysis in horizontal CVD reactor

  • Lee, Jung-Hun;Yoo, Jin-Bok;Bae, So-Ik
    • 한국결정성장학회지
    • /
    • 제15권4호
    • /
    • pp.135-140
    • /
    • 2005
  • Thermal-fluid analysis was performed to understand the thermal behavior in the horizontal CVD reactor thereby to design a susceptor which has a uniform deposition rate during silicon EPI growing. Four different types of susceptor designs, standard (no hole susceptor), hole $\sharp$1 (240 mm), hole $\sharp$2 (150 mm) and hole $\sharp$3 (60 mm), were simulated by CFD (Computational Fluid Dynamics) tool. Temperature, gas flow, deposition rate and growth rate were calculated and analyzed. The degree of flatness of EPI wafer loaded on the susceptor was computed in terms of silicon growth rate. The simulation results show that the temperature and thermal distribution in the wafer are greatly dependent on inner diameter of hole susceptor and demonstrate that the introduction of hole in the susceptor can degrade wafer flatness. Maximum temperature difference appeared around holes. As the diameter of the hole decreases, flatness of the wafer becomes poor. Among the threes types of susceptors with the hole, optimal design which resulted a good uniform flatness ($5\%$) was obtained when using hole $\sharp$1.