• 제목/요약/키워드: thermal discharge

검색결과 629건 처리시간 0.025초

증기제트 방출시 과냉각수조 내의 열혼합 현상 CFD 해석 (CFD Analysis for Thermal Mixing in a Subcooled Water during Steam Jet Discharge)

  • 강형석;송철화
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.513-514
    • /
    • 2006
  • A CFD analysis for a thermal mixing experiment during steam jet discharge was performed to develop the analysis methodology for the thermal mixing between steam and subcooled water and to find the optimized numerical method. In the CFD analysis, the steam condensation phenomena by a direct contact was modelled by the so-called condensation region model. The comparison of the CFD results with the test data showed a good agreement as a whole, but a small temperature difference was locally found at some locations. However, the commercial CFD code of CFX4.4 together with the condensation region model can simulate the thermal mixing behaviour reasonably well when a sufficient number of mesh distribution and a proper numerical method are adopted

  • PDF

물받이를 이용한 유수발전장치의 설계 및 구현 (Design and Implementation of Fluid Flow Generation System by using Water Captures)

  • 손영대;정현석
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.413-421
    • /
    • 2012
  • This paper proposes the design and implementation of fluid flow generation system by using polypropylene(PP) water capture, which harvests electric energy from the kinetic energy of tidal current or water flow and drives the desired load, and applies it to the discharge drain of Hadong thermal power plant. This experimental system is composed of water captures, driving wheel, gear trains, 10[kW] synchronous generator, and three phase rectifying circuit which drives lamp load for test. The proposed water capturing system which is composed of water captures, rope and driving wheel, rotates as caterpillar according to water flow. This system is very easy to manufacture and more economical than another type of tidal current turbines such as conventional propeller and helical type. Also, we estimated the available fluid flow energy that can be extracted from the cooling water in discharge drain based on drain's cross-sectional area. Therefore, this paper confirms the validity of proposed fluid flow generation system with water captures and the possibility of its application for renewable energy generation in discharge drain of thermal power plant, from the obtained performance characteristic of this energy conversion system.

표면온배수 수치모형 : 제트적분모델의 비교평가 (Numerical Models for the Surface Discharge of Heated Water : Comparative Evaluation of Jet Integral Models.)

  • 최흥식;이길성
    • 물과 미래
    • /
    • 제23권4호
    • /
    • pp.487-497
    • /
    • 1990
  • 원자력·화력, 제철소 등의 임해공업시설로부터 온수 방출의 확산에 대한 정성, 정량적 예측은 환경관리 및 냉각수 취·배수로 설계에 매우 중요하다. 본 연구는 난류 및 부력효과가 강한 온배수의 주요 물리적 특성을 규명하고 실무에 많이 사용되고 있는 MIT 및 PDS 적분모델의 비교평가를 실시하였다. 일반적으로 MIT 및 PDS 모델은 성층화되지 않은 수역에서 주위수 및 제트 방출각도를 고려하여 온배수 거동을 산정하는 모델이다. 해석결과는 그 구성의 상이성에 의해 매우 다름이 규명되어, 온배수의 정확한 산정을 위해서는 난류모델을 이용한 수치모델의 개발 및 이의 적용이 요구된다.

  • PDF

Investigations on Partial Discharge, Dielectric and Thermal Characteristics of Nano SiO2 Modified Sunflower Oil for Power Transformer Applications

  • Nagendran, S.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1337-1345
    • /
    • 2018
  • The reliability of power transmission and distribution depends up on the consistency of insulation in the high voltage power transformer. In recent times, considering the drawbacks of conventional mineral oils such as poor biodegradability and poor fire safety level, several research works are being carried out on natural ester based nanofluids. Earlier research works show that sunflower oil has similar dielectric characteristics compared with mineral oil. BIOTEMP oil which is now commercially available in the market for transformers is based on sunflower oil. Addition of nanofillers in the base oil improves the dielectric characteristics of liquid insulation. Only few results are available in the literature about the insulation characteristics of nano modified natural esters. Hence understanding the influence of addition of nanofillers in the dielectric properties of sunflower oil and collecting the database is important. Considering these facts, present work contributes to investigate the important characteristics such as partial discharge, lightning impulse, breakdown strength, tandelta, volume resistivity, viscosity and thermal characteristics of $SiO_2$ nano modified sunflower oil with different wt% concentration of nano filler material varied from 0.01wt% to 0.1wt%. From the obtained results, nano modified sunflower oil shows better performance than virgin sunflower oil and hence it may be a suitable candidate for power transformer applications.

원환풀내에서 Quencher Device에 의한 고온수 분출로 일어나는 혼합유동에 관한 연구 (Analysis of Flow and Thermal Mixing Responses on Hot Water Discharge by Quencher Devices into an Annular Water pool)

  • 최성석;김종보
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.21-30
    • /
    • 1985
  • One of the problems with the Boiling Water Reactor involves the flow and thermal mixings in the suppression water pool high pressure steam discharge into the pool in case of emergency core relief. Varioos heat sensitive devices and pumps for the reactor core cooling are installed in the middle of the suppression pool. Especially the pumps utilize pool water in order to cool the reactor core in emergency cases. In this case, the water temperature for the reactor cool ins should be below a certain temperature specified by the reactor design. In the present investigation, in other to determine the optimum locations of these pumping devices, numerical solutions have been obtained for the model to determine the f low mixing characteristics. Experimental investigations have also been carried out for the flow mixing and for the thermal mixing in the pool during the discharge. Considering that the discharge steam through the Quenching Device becomes hot water immediately in the water pool, the steam- equivalent hot water has been utilized. Examining these characteristices, it becomes possible to deform me the best locations for RCIC, LPCI , HPCI pumps in the suppression water pool for the emermency reactor core cooling.

  • PDF

SPICE를 이용한 커패시터 방전 임펄스 착자 회로의 특성 해석 (Characteristics Analysis of Capacitor Discharge Impulse Magnetizing Circuit using SPICE)

  • 백수현;김필수
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.206-215
    • /
    • 1994
  • A method for simulating general characteristics and temperature characteristics of discharging SCR of the capacitor discharge impulse magnetizer-magnetizing fixture system using SPICE is presented. This method has been developed which can aid the design, understanding and inexpensive, time-saving of magnetizing circuit. As the detailed characteristic of magnetizing circuit can be obtained, the efficient design of the magntizing circuit which produce desired magnet will be possible using our SPICE modeling. Especially, computation of the temperature rise of discharging SCR is very important since it gives some indication of thermal characteristic of discharging circuit. It is implemented on a 486 personal computer, and the modeling results are checked against experimental measures. The experimental results have been achived using 305[V] and 607[V] charging voltage, low-energy capacitor discharge impulse magnetizer-magnetizing fixture of air cleaner DC motor.

  • PDF

원자력발전소 온배수 영향 해양물리분야 조사의 표준지침 (A Standard Guide to Physical Oceanographic Survey of the Effect of Thermal Discharge from a Nuclear Power Plant)

  • 이재학;노영재;조양기
    • 한국해양학회지:바다
    • /
    • 제12권1호
    • /
    • pp.43-49
    • /
    • 2007
  • 원자력발전소 온배수 영향 조사 과정상 문제점을 평가하고 대안으로서 조사 표준 지침을 제시하였다. 관측이나 온배수 확산 모델링 단독으로 이루어진 지금까지의 방법으로는 시간에 따른 온배수에 의한 수온 분포의 변화를 정량적으로 파악하는데 한계가 있으므로, 관측과 온배수 확산 수치모델링의 상호 보완적인 조사를 병행하는 것이 바람직하다. 현장 관측은 원자력발전소 인근 해역의 모든 자연적 열원의 영향을 고려한 열수지 모형의 개념에 근거한 조사가 중요하며, 수치모델링의 결과를 기준 수온분포로서 활용하고자 할 경우에는 수치모델링에 의한 현상 재현이 통계적 유의수준에 도달한 경우에 한정하도록 하였다. 또한, 과거의 순환 및 확산 모델링의 문제점을 개선하기 위한 대안으로서 표준코드의 개발을 제안하였다.

온배수 확산 평가를 위한 열적외선 위성관측 비교 (The Comparison of Thermal Infrared Satellite Observation for Plume Assessment of Thermal Discharge)

  • 정종철
    • 환경영향평가
    • /
    • 제24권4호
    • /
    • pp.367-374
    • /
    • 2015
  • 해수 표층 수온은 원자력발전소의 온배수 영향을 조사하기 위해서 위성원격탐사에 의해 관측되는 가장 중요한 정보들 중 하나이다. 하지만 Landsat 7 위성과 Landsat 8 위성의 열적외선 센서로부터 추출한 표층수온과 실측치를 비교한 연구는 부족하다. Landsat 8 위성은 표층수온을 추출하기 위해 열적외선 센서에 두 개의 분리된 밴드를 가지고 있지만, Landsat 7은 한 개의 밴드를 사용하고 있다. 그럼에도 불구하고 본 연구에서는 Landsat 7 ETM+센서가 Landsat 8 TIRS 보다 표층수온의 보정에 유용하다는 것을 제시하였다. 본 연구에서는 Landsat 114-36 지역의 15개 위성자료를 가지고 ENVI와 IDL을 이용한 표층수온 알고리즘을 처리하였다. 국립해양조사원으로부터 수집한 표층수온 실측자료와 위성에서 추출한 표층수온을 비교하였고, 위성관측 시계열 자료와 측정지점의 실측자료를 통해 정확도를 비교하였다.

저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발 (Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process)

  • 유정석;백민수;김태희;김정일;김유석;최석호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

중형 상용차 통풍형 브레이크 디스크의 제동 시 열 유동 및 변형 해석 (Thermal Fluid Flow and Deformation Analysis of Medium Commercial Vehicle Ventilated Brake Disc in Braking)

  • 강채욱;최규재
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.63-69
    • /
    • 2014
  • Domestic automobile companies have adopted drum type brake system for commercial vehicles. However recently those companies have been applying disc-brake system to solve vehicle control-instability and inefficient heat discharge performance of conventional drum brake system for a medium commercial vehicle. Because the kinetic energy of a running commercial vehicle is relatively high, the brake system should discharge lots of heat energy while braking. A ventilated type brake disc has been used to increase heat discharge performance of a brake system. The vent structure of a disc highly affects cooling efficiency. This paper compares thermal characteristics of three types of vent structure in JASO C421 braking condition. It is found that the slant bend type disc has the lowest temperature and thermal stress distributions in the braking condition.