• Title/Summary/Keyword: thermal discharge

검색결과 627건 처리시간 0.031초

열전지용(MS2, M=Fe, Ni, Co)계 양극의 전기화학적 특성 연구 (Effect of Cathode Materials (MS2, M=Fe, Ni, Co) on Electrochemical Properties of Thermal Batteries)

  • 이정민;임채남;윤현기;정해원
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.583-588
    • /
    • 2017
  • Thermal batteries are used in military power sources that require robustness and long storage life for applications in missiles and torpedoes. $FeS_2$ powder is currently used as a cathode material because of its high specific energy density, environmental non-toxicity, and low cost. $MS_2$ (M = Fe, Ni, Co) cathodes have been explored as novel candidates for thermal batteries in many studies; however, the discharge characteristics (1, 2, 3 plateau) of single cells in thermal batteries with different cathodes have not been elucidated in detail. In this study, we independently analyzed the discharge voltage and calculated the total polarizations of single cells using $MS_2$ cathodes. Based on the results of this study, we propose $NiS_2$ as a potential cathode material for use in thermal batteries.

울진 주변 해역 대형저서동물 군집의 시·공간 분포와 환경요인과의 관계 (Spatiotemporal Distribution of Macrobenthic Communities in the Coastal Area of Uljin and Its Relation to Environmental Variables)

  • 유옥환;백상규;이형곤;이재학
    • Ocean and Polar Research
    • /
    • 제33권4호
    • /
    • pp.421-434
    • /
    • 2011
  • Although thermal effluent from coastal power plants affects marine ecosystems, few studies have examined the spatiotemporal distribution of macrobenthic communities in a coastal area of Korea with thermal discharge. This study analyzed the species composition and abundance of a macrobenthic community in relation to environmental variables for a period of 1 year. In total 334 macrobenthic faunal species were collected; the mean density was 3,221 ind/$m^2$. The number of species and the density of macrobenthic fauna increased with distance from the thermal discharge site. Cluster analysis indicated that the macrobenthic community could be divided into two groups: group I in shallow (< 30 m deep) and group II in the outer areas (> 30 m deep). Group I showed the lowest species density and diversity. Four polychaetes, including Magelona japonica, Spiophanes bombyx, Scolotoma longifolia and Chaetozone setosa, all of which have been dominant species since 1987, exhibited higher mean densities in the area distant from the thermal discharge (the outer and north areas). Conversely, the warm-adapted and opportunistic species, such as the amphipods Urothoe convexa and Mandibulophoxus mai, the bivalve Felaniella sowerbyi, and the polychaete Rhynchospio sp., were more abundant in the thermal discharge region. The results of this study indicate that thermal effluent influences macrobenthic communities in the shallow area, while other environmental variables, such as depth, sediment grain size, and TOC, are more important determinants of the macrobenthic communities in deeper regions (> 30 m deep).

발전기 고정자 권선의 부분방전 특성을 이용한 절연진단 연구 (A Study on Insulation Diagnosis by Partial Discharge Spectroscopy of Generator Stator Winding)

  • 강동식;김용주;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.584-587
    • /
    • 1993
  • Mica, which have a good thermal and electrical characteristics, while will cleave easily at these layers. In order to bond mica materials soldily, mica/epoxy composite insulation materials were developed for generator stator winding. There are lots of problems such as delamination and partial discharge of these insulation materials caused by mechanical, electrical and thermal aging. Several experiments have been conducted in order to find the useful diagnostic parameters from the partial discharge phenomena by applying a new measurement techniques. this paper deals with the partial discharge pulse characteristics, which may be a useful diagnostic concept in predicting insulation condition of generator stator insulation materials. Long term insulation aging test shows that partial discharge phase angle an magnitude are identified as one of the main key techniques for insulation diagnosis on generator stator winding.

  • PDF

Characterization of Acid-soluble Collagen from Alaska Pollock Surimi Processing By-products (Refiner Discharge)

  • Park, Chan-Ho;Lee, Jae-Hyoung;Kang, Kyung-Tae;Park, Jae-W.;Kim, Jin-Soo
    • Food Science and Biotechnology
    • /
    • 제16권4호
    • /
    • pp.549-556
    • /
    • 2007
  • The study was carried out to examine on the refiner discharge from Alaska pollock as a collagen resource by characterizing biochemical and functional properties of collagen. The refiner discharge from Alaska pollock surimi manufacturing was a good resource for collagen extraction according to the results of total protein, heavy metal, volatile basic nitrogen, collagen content, amino acid composition, and thermal denaturation temperature (TDT). TDT of acid soluble collagen from refiner discharge showed $20.7^{\circ}C$, which was similar to that of collagen from Alaska pollock muscle and was higher than that of collagen from Alaska pollock skin. TDT of acid-soluble collagen from refiner discharge was, however, lower than those of skin collagens from warm fish and land animal. Acid-soluble collagen from refiner discharge of Alaska pollock could be used as a functional ingredient for food and industrial applications according to the results of water and oil absorption capacities, and emulsion properties. In addition, if the thermal stability of the acid-soluble collagens is improved, collagen from refiner discharge from Alaska pollock could be more effectively used.

지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3) (The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System)

  • 한정상;이주현;김영식;이광진;홍경식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

리튬이온 배터리의 분리막 손상 요인별 방전펄스의 검출과 분석 (Detection and Analysis of Discharge Pulses by Failure Mechanisms of the Separator inside Lithium-Ion Batteries)

  • 임승현;이경렬;김남훈;김동언;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.327-332
    • /
    • 2021
  • Lithium-ion batteries (LIBs) have become a main energy storage device in various applications, such as portable appliances, renewable energy facilities, and electric vehicles. However, the poor thermal stability of LIBs may cause explosion or fire. The thermal runaway is the result of a failure of the separator inside LIB. Damages like tearing, piercing, and collapsing of the separator were simulated in a mechanical, an electrical, and a thermal way, and small discharge pulses of a few mV were detected at the time of separator damages. From the experimental results, this paper provided a method that can identify the separator failure before thermal runaway in the aspect of a potential explosion and fire prevention measures.

평판형 유전체 장벽 방전 반응기에서 충진물질에 따른 아세토나이트릴의 분해 특성 (Decomposition of Acetonitrile Using a Planar Type Dielectric Barrier Discharge Reactor Packed with Adsorption and Catalyst Materials)

  • 김관태;송영훈;김석준
    • 한국대기환경학회지
    • /
    • 제19권2호
    • /
    • pp.157-165
    • /
    • 2003
  • A combined process of non-thermal plasma and catalytic technique has been investigated to treat $CH_3$CN gas in the atmosphere. A planar type dielectric barrier discharge (DBD) reactor has been used to generate the non-thermal plasma that produces various chemically active species, such as O, N, OH, $O_3$, ion, electrons, etc. Several different types of the beads. which are Molecular Sieve (MS) 5A, MS 13X, Pt/alumina beads, are packed into the DBD reactor, and have been tested to characterize the effects of adsorption and catalytic process on treating the $CH_3$CN gas in the DBD reactor. The test results showed that the operating power consumption and the amounts of the by-products of the non-thermal plasma process can be reduced by the assistance of the adsorption and catalytic process.

수중 하베스트형 빙축열시스템의 축방냉 특성 실험 (Experiment on the Charge and Discharge of Thermal Energy for Under-Water Harvest-Type Ice Storage System)

  • 김재돌
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.11-17
    • /
    • 2002
  • This paper is concerned with the development of a new method for making, separating ice and storage floated ice by installing an evaporation plate at under-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating an ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. Developed new harvest-type method shows good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, however these components are not necessary in a new method. In this study ice storage systems are experimentally investigated to study the charge and discharge of thermal energy. The results show the applicable possibility and performance enhancement of a new type.

유전체 장벽 방전에 의한 벤젠의 분해 (Decomposition of Benzene by Dielectric Barrier Discharge)

  • 이용훈;이재호;박동화
    • 공업화학
    • /
    • 제18권3호
    • /
    • pp.213-217
    • /
    • 2007
  • 본 연구에서는 유전체장벽방전을 이용하여 휘발성 유기화합물의 일종인 벤젠의 분해 경향과 분해 생성물의 선택성에 대해서 연구하였다. 유전체장벽방전의 공정변수에 따른 벤젠의 분해율과 분해 생성물의 선택성을 높이기 위해서 반응기 내부에 촉매(H-ZSM-5, Na-Y)를 사용하였다. 실험은 대기압에서 수행하였으며, 방전전압, 체류시간, 농도 등의 공정변수에 따른 분해율을 조사하였다. 유전체 장벽방전만을 사용하는 방법과 비교하여 여기에 촉매를 동시에 사용하는 하이브리드 방전이 같은 전압과 체류시간조건에서 보다 효과적인 벤젠의 분해 방법임을 확인하였다.

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF