• Title/Summary/Keyword: thermal crown

Search Result 70, Processing Time 0.043 seconds

THE EFFECTS OF THERMAL STIMULI TO THE FILLED TOOTH STRUCTURE (온도자극이 충전된 치질에 미치는 영향)

  • Baik, Byeong-Ju;Roh, Yong-Kwan;Lee, Young-Su;Yang, Jeong-Suk;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.339-349
    • /
    • 1999
  • The dental structure substituted by restorative materials may produce discomfort resulting from hot or cold stimuli. To investigate the effects of this stimuli on the human teeth, thermal analysis was carried out by calculation of general heat conduction equation in a modeled tooth using numerical method. The method has been applied to axisymmetric and two-dimensional model, analyzing the effects of constant temperature $4^{\circ}C\;and\;60^{\circ}C$. That thermal shock was provided for 2 seconds and 4 seconds, respectively and recovered to normal condition of $20^{\circ}C$ until 10 seconds. The thermal behavior of tooth covered with a crown of gold or stainless steel was compared with that of tooth without crown. At the same time, the effects of restorative materials(amalgam, gold and zinc oxide-eugenol(ZOE)) on the temperature of PDJ(pulpo-dentinal junction) has been studied. The geometry used for thermal analysis so far has been limited to two-dimensional as well as axisymmetric tooth models. But the general restorative tooth forms a cross shaped cavity which is no longer two-dimensional and axisymmetric. Therefore, in this study, the three-dimensional model was developed to investigate the effect of shape and size of cavity. This three-dimensional model might be used for further research to investigate the effects of restorative materials and cavity design on the thermal behavior of the real shaped tooth. The results were as follows; 1. When cold temperature of $4^{\circ}C$ was applied to the surface of the restored teeth with amalgam for 2 seconds and recovered to ambient temperature of $20^{\circ}C$, the PDJ temperature decreased rapidly to $29^{\circ}C$ until 3 seconds and reached to $25^{\circ}C$ after 9 seconds. This temperature decreased rather slowly with stainless steel crown, but kept similar temperature within $1^{\circ}C$ differences. Using the gold as a restorative material, the PDJ temperature decreased very fast due to the high thermal conductivity and reached near to $25^{\circ}C$ but the temperature after 9 seconds was similar to that in the teeth without crown. The effects of coldness could be attenuated with the ZOE situated under the cavity. The low thermal conductivity caused a delay in temperature decrease and keeps $4^{\circ}C$ higher than the temperature of other conditions after 9 seconds. 2. The elapse time of cold stimuli was increased also until 4 seconds and recovered to $20^{\circ}C$ after 4 seconds to 9 seconds. The temperature after 9 seconds was about $2-3^{\circ}C$ lower than the temperature of 2 seconds stimuli, but in case of gold restoration, the high thermal conductivity of gold caused the minimum temperature of $21^{\circ}C$ after 5 seconds and got warm to $23^{\circ}C$ after 9 seconds. 3. The effects of hot stimuli was also investigated with the temperature of $60^{\circ}C$. For 2 seconds stimuli, the temperature increased to $40^{\circ}C$ from the initial temperature of $35^{\circ}C$ after 3 seconds of stimuli and decreased to $30^{\circ}C$ after 9 seconds in the teeth without crown. This temperature was sensitive to surface temperature in the teeth with gold restoration. It increased rapidly to $41^{\circ}C$ from the initial temperature of $35^{\circ}C$ after 2 seconds and decreased to $28^{\circ}C$ after 9 seconds, which showed $13^{\circ}C$ temperature variations for 9 seconds upon the surface temperature. This temperature variations were only in the range of $5^{\circ}C$ by using ZOE in the bottom of cavity and showed maximum temperature of $37^{\circ}C$ after 3 seconds of stimuli.

  • PDF

냉연 강판의 폭방향 판두께 제어 기술

  • 배원형;박해두;최재찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.512-517
    • /
    • 1993
  • The cold rolled strip meets continuously rising demands on the less deviation of thickness at the width direction of their rolled products. Especially, the special interest has been to find the methods to reduce the edge drop which influences seriously on the yield losses and the quality of the rolled products. In this study, the influence of hot coils on the thickness profile of cold rolled strip was analyzed. For obtainint the tapered work roll shig\ft conditions, the thermal crown and the flattening between the work roll and the strip were calculated, and the main parameters which have mostly effects on the edge drop were simulated. Also the obtained conditions from the simulation were applied to Tandem Cold Rolling Mill to investigate the change of the edge drop and the crown ratio depending on the amount of work roll taper and the length of contact of taper. The results of the application led to better thickness profile than conventional one.

  • PDF

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

Numerical Analysis for Temperature Distribution and Thermal Stresses in a Turbocharged Large CNG Engine Piston (터보과급 대형 CNG기관 피스톤의 온도분포와 열응력 해석)

  • Kim, Yang-Sul;An, Su-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.58-62
    • /
    • 2008
  • The purpose of this paper is to establish a standard finite element analysis model of a piston by carrying out three dimensional modeling of a series six-cylindered CNG engine's piston to forecast temperature distribution at stationary state and the following thermal stress and variation, and cross checking it with existing analysis. Also, in order to evaluate the affects of the cooling system to the piston's heat load, the paper analyzed piston's temperature and thermal stress distribution according to the cooling water temperature changes and the following variations. As a result, the maximum temperature was found at the center of the crown in the piston and the maximum thermal stress occurred from the lower part of the piston.

  • PDF

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

The Shape Optimal Design of Marine Medium Speed Diesel Engine Piston (박용(舶用) 중속(中速) 디젤엔진 피스톤의 형상최적설계(形狀最適設計))

  • Lee, Jun-Oh;Seong, Hwal-Gyeng;Cheon, Ho-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.59-70
    • /
    • 2008
  • Polynomial is used to optimize crown bowl shape of a marine medium speed diesel engine piston. The primary goal of this paper is that it's for an original design through a thermal stress and highest temperature minimum. Piston is modeled using solid element with 6 design variables defined the positional coordinate value. Global optimum of design variables are found and evaluated as developed and integrated with the optimum algorithm combining genetic algorithm(GA) and tabu search(TS). Iteration for optimization is performed based on the result of finite element analysis. After optimization, thermal stress and highest temperature reduced 0.68% and 1.42% more than initial geometry.

A Study on Opaque Porcelain for P.F.M Crown - Focused on Paste Opaque - (도재전장관용 Opaque 도재에 관한 연구 - paste opaque을 중심으로 -)

  • Kim, Sa-Hak;Ko, Dae-Jin;Lee, Yong-Keun;Kim, Kwang-Mahn;Kim, Kyoung-Nam
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.211-221
    • /
    • 2002
  • The purpose of this study was to analyze the commercial paste opaque products currently available in domestic of foreign as well as domestic, such as Duceram Plus(DU; Ducera Dental GmbH, Germany), VMK 95(VM; Vita Co., Germany), Noritake EX-3(EX; Noritake Co., Japan) and Ceramax(CE; Alphadent Co., Korea). They were characterized in thermal expansion coefficient, particle size distribution, viscosity and solvent using thermomechanical analyzer, particle size analyzer, rheometer and infrared spectrophotometer. Experimental results are as follows; Firstly, thermal expansion coefficients were determined $13.9{\times}10-6/^{\circ}C$ for DU, $14.3{\times}10-6/^{\circ}C$ for VM, $13.3{\times}10-6/^{\circ}C$ for EX, and $14.0{\times}10-6/^{\circ}C$ for CE. Secondly, percent of partice size below $1{\mu}m$ were 12% for DU, VM and CE, and 13% for EX, percent between $1{\mu}m$ and $5{\mu}m$ were 42% for DU, 42% for VM, 38% for EX, and 61 % for CE, percent between $5{\mu}m$ and $10{\mu}m$ were 21 % for DU, 24% for VM, 20% for EX, and 18% for CE, and over $10{\mu}m$ were 25% for DU, 22% for VM, 29% for EX, 9% for CE. Thirdly, the basic composition of the solvent in all of the commercial paste opaques were determined as ethylene glycol from FT-IR investigation. Lastly, measured viscosities were 1798 cp for DU, 536 cp for VM, 1110 cp for EX, and 721 cp for CE.

  • PDF

The Decision on the Thermal Expansion Coefficient of the Glass Infiltrated in All Ceramic Crown (전부도재관 제작용 침투유리의 열팽창계수의 결정)

  • 김병수;이득용;김학관;장주웅
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.1
    • /
    • pp.93-97
    • /
    • 2003
  • Using alumina-glass infiltrated material which has been in the spotlight of biomaterials including dental material, appropriate composition of glass infiltrated material mainly depends on the thermal expansion coefficient. To obtain proper compositional glass of suitable thermal expansion coefficient effiiently. a Taguchi analysis was conducted. The influence of alkali oxide and alkali earths oxide, which affect mostly the thermal expansion coefficient of glass infiltrated material, was infiltrated material, the effect having influenced on the thermal expansion coefficient of glass was presented in this order (Na$_2$O≫K$_2$O ≫MgO≒CaO). The effect of Na$_2$O was about eight times as great as the effects of MgO, CaO and $K_2$O was about four times. Among the interaction affects of each variables the interaction affects of $K_2$O-CaO showed most significantly and thermal expansion property of specified composition was predicted by calculating contribution rate on each level of variables and interaction affects.