• 제목/요약/키워드: thermal control design

검색결과 642건 처리시간 0.029초

발전플랜트의 다단계 분산제어기 설계 (Design of a decentralized multilevel control for thermal power plant)

  • 이은호;김석우;김영철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1217-1220
    • /
    • 1996
  • For the purpose of the good tracking to variable load demands of the thermal power plant, a decentralized multilevel control(DMC) scheme is presented. It is applied to the drum type boiler-turbine system which is simplified from Boryung T/P #1,2 model[4]. A linearized model is decomposed into three subsystems by means of linear transformation. Then the DMC based on such subsystem is designed. Simulation using Matlab-Simulink shows that the proposed algorithm works very well to the large step change of power demand.

  • PDF

해양플랜트 사무공간의 공조 쾌적성 평가에 관한 연구 (The Study for Evaluation of thermal comfort in office on offshore)

  • 임홍석;김판중
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.67-72
    • /
    • 2017
  • This paper presents on the evaluation of thermal comfort in office on offshore. In living quarter of offshore, strict air conditioning performance is required to office on offshore and displacement ventilation is applied to office space which rooms are required to confirm the thermal environment. The computational fluid dynamics (CFD) is performed to calculate the temperature, air velocity in office and thermal comfort such as PPM & PPD is evaluated by the CFD result.

  • PDF

마이크로 콘트롤러를 이용한 의료용 열전식 프린터 모듈의 개발에 관한 연구 (Design of the Medical Thermal Array Printer Module Based on Microcontroller)

  • 이명호;공인욱;권혁제
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.129-138
    • /
    • 1996
  • This paper describes design techniques of general purpose thermal array printer, especially easily applicable to medical measurement equipment. The'general'means that the proposed thermal array printer can be applied to not only medical field but other industrial field by establishing the eligible protocol. The thermal array printer is composed of i)MPU and its peripherals ii)printer head control, iii)diverse protection circuits, and iv)serial communication. In this paper the performance of the proposed thermal array printer was evaluated by applying to an 3 channel electrocardiogram recorder. The propped system can support'Hangul'text as well as alphanumeric characters and any bitmap image.

  • PDF

LQG 설계에 의한 RTP 온도제어 시스템 (An RTP Temperature Control System Based on LQG Design)

  • 송태승;유준
    • 제어로봇시스템학회논문지
    • /
    • 제6권6호
    • /
    • pp.500-505
    • /
    • 2000
  • This paper deals with wafer temperature uniformity control essential in rapid thermal processing (RTP). One of the important control objectives of RTP is to keep the temperature over the wafer surface as uniformly as possible. For this, a discrete time state equation around the operating point is first identified by using the subspace fitting method, and a multivariable LQG(Linear Quadratic Gaussian) controller is designed based on the identified model. Simulation and experimental results show improvement in temperature uniformity over the conventional PID method.

  • PDF

슬래브형 매스콘크리트 구조물의 온도균열제어 (Temperature Crack Control in Slab Type구s Mass Concrete Structures)

  • 김동석;구본창;하재담;진형하;오승제;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.333-336
    • /
    • 1999
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as mat-slab of nuclear reactor buildings, dams or large footings, foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, pre-cooling which lowers the initial temperature of fresh concrete with ice flake, pipe cooling which cools the temperature of concrete with flowing water, design change which considers steel bar reinforcement, operation control and so on. The Aim of this paper is to verify the effect of low heat blended cement in reducing thermal stress in slab type's mass concrete such as container harbor structures.

  • PDF

제어보드와 파워보드에 관한 발열성능 평가 (Evaluation of Control Board and Power Board Thermal Performance)

  • 장성철;권민수
    • 한국산업융합학회 논문집
    • /
    • 제20권2호
    • /
    • pp.187-194
    • /
    • 2017
  • This study examined the validity and reliability of the thermal safety design, in order to maintain the heat generated from integrated circuit (IC) chips in the converter, condenser, resistor, and transistor (which are considered as heat sources for thermoelectric devices with a printed circuit board) below target levels during the process of developing a control board and a main power board. The study analyzed the heat generation and dissipation characteristics of the entire printed circuit board (PCB) model to examine its thermal safety.

수화열 발생인자가 지하철 콘크리트 구조물의 내구설계에 미치는 영향 (Effect of the factor developing the Heat of Hydration on Durability Design in the Subway Concrete Structure)

  • 임영수;김은겸;성기한
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1131-1137
    • /
    • 2004
  • With the recent continuous expansion of subways, newly created subways tend to have lower locations and wider sections. Furthermore. since box structures and evacuating tunnels are classified into a category of mass-concrete. the thermal-stress, emitted from the inside. causes cracks to structures from the inception of constructing. In this paper, thermal-stress analysis and durability evaluation of box structure were carried out to investigate relationship between durability and parameter causing the heat of hydration. Through the examination, this paper tries to find out satisfactory solutions to regulated thermal crack and ensure the required duration period. The results of this paper showed that to control thermal crack and guarantee the required duration period it was more effective to use low-heat-portland cement and moderateheat-portland cement. As cement volume due to reduction of water-cement ratio increased, the possibility of thermal cracks occurrence increased but results of durability evaluation was different depending on evaluation method. The results showed that the appropriate water-cement ratio to control the heat of hydration and satisfy the required durability was $45\∼55\%$. And it was showed that during placement of concrete blocks ambient temperature affect the heat of hydration. thermal crack and long-term durability largely and when concrete was placed at low temperature to control thermal crack. it need to try to guarantee the required duration period. Henceforth, by studying not only internal and external conditions, such as the relative humidity and the unit weight. but also methods, to evaluate durability, in accordance with domestic situations, more reasonable design of durability should be achieved.

  • PDF

화재상황에서 적용가능한 열화상 카메라의 파노라마 촬영을 위한 동일점 추출 알고리즘 (Image Matching Algorithm for Thermal Panorama Image Construction Adaptable for Fire Disasters)

  • 곽동기;김동환
    • 제어로봇시스템학회논문지
    • /
    • 제22권11호
    • /
    • pp.895-903
    • /
    • 2016
  • In a fire disaster in a tunnel, people should be rescued immediately using the information obtained from cameras or sensors. However, in heavy smoke from a fire, people cannot be clearly identified by a mounted CCTV, which is only effective in a clear environment. A thermal camera can be an alternative to this in smoky situations and is capable of detecting people from their emitted thermal energy. On the other hand, the thermal image camera has a smaller field of view than an ordinary camera due to its lens characteristics and temperature error, etc. In order to cover a relatively wide area, panoramic image construction needs to be implemented. In this work, a template-based similarity matching algorithm for constructing the panorama image is proposed and its performance is verified through experiments. This scheme provides guidelines for coping with difficulty in image construction, which requires an exact correspondence search for two images in cases of heavy smoke.

단열재가 부착된 수직벽 표면의 온도제어 해석 (Analysis on Surface Temperature Control of an Insulated Vertical Wall Under Thermal Radiation Environment)

  • 강병하;피창헌;김석현
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.323-329
    • /
    • 2012
  • In this study, a rational procedures for estimation of insulation thickness of a vertical wall for condensation control or personnel protection has been investigated. Design parameters are height of the wall, thermal conductivity, emissivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient.

Evaluation of thermal comfort and cooling loads for a multistory building

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • 제5권1호
    • /
    • pp.65-77
    • /
    • 2017
  • The latest UK Climate Projections (UKCP09) show that mean daily temperatures will increase everywhere in the United Kingdom. This will significantly affect the thermal and energy performance of the current building stock. This study examines an institutional fully glazed building and looks into the changes in the cooling loads and thermal comfort of the occupants during the occupied hours of the non-heating period. Furthermore, it investigates the effect of relative humidity (RH) on thermal comfort. The Design Summer Year (DSY) 2003 for London Heathrow has been used as a baseline for this study and the DSY 2050s High Emissions scenario was used to examine the performance of the building under future weather conditions. Results show a 21% increase of the cooling loads between the two examined scenarios. Thermal comfort appears to be slightly improved during the months of May and September and marginally worsen during the summer months. Results of the simulation show that a relative humidity control at 40% can improve the thermal comfort for 53% of the occupied hours. A comparison of the thermal comfort performance during the hottest week of the year, shows that when the relative humidity control is applied thermal comfort performance of the 2050s is similar or better compared to the thermal comfort performance under the baseline.