• 제목/요약/키워드: thermal control design

검색결과 643건 처리시간 0.032초

A Combined Lookup Table and PI-type Controller for Temperature Control of Thermal Process

  • Tojang, Weerasak;Pannil, Pittaya;Chaikla, Amphawan;Julsereewong, Prasit;Tirasesth, Kitti
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1088-1092
    • /
    • 2003
  • This paper presents a combined lookup table technique and PI-type controller. The purpose of the designed controller is applied to control the nonlinear system as thermal process. The proposed controller is easy and convenient to design based on a commercial controller. The performances of the proposed controller were studied using the thermal plant model under temperature control. The experimental results included demonstrate the good performance of the proposed controller.

  • PDF

축열식 심야전력기기를 위한 축열량 제어기 설계 (Design of a Controller for the Heat Capacity of Thermal Storage Systems Using Off-Peak Electricity)

  • 이은욱;양해원
    • 제어로봇시스템학회논문지
    • /
    • 제7권1호
    • /
    • pp.1211-1217
    • /
    • 2001
  • This paper presnts a controller for the heat capacity of thermal storage systems using off-peak electricity which is composed of an identifier using neural networks and a storage time adjuster in order to store exactly the required thermal energy without loss. Since thermal storage systems have nonlinear characteristics and large time constant, even if we predict the heating load accurately, it is very difficult to store exactly the required thermal energy. Thus, in the neural network for the identifier, the adaptive learning rate for high learning speed and bit inputs based on state changes of thermal storage power source are used. Also a hardware for the controller using a microprocessor is developed. The performance of the proposed controller is shown by experiment.

  • PDF

실리콘 고분자 복합소재의 열전도도와 기계적 물성에 관한 연구 (A Study on the Thermal Conductivity and Mechanical Properties of Electrical Insulation Polymer Composite Materials)

  • 최원일;최계광
    • Design & Manufacturing
    • /
    • 제18권3호
    • /
    • pp.37-43
    • /
    • 2024
  • With the development of technology in the electrical and electronic field, research on heat dissipation materials that can efficiently emit and control heat to solve the heat generation problem is being actively conducted. Since heat dissipation materials require electrical insulation and thermal conductivity, the polymer composite material was manufactured by mixing chemically stable silicone resins and ceramic fillers, and thermal conductivity and mechanical properties were observed. At the same filling amount, the larger the particle size and the higher the high thermal conductivity filler was added, the higher the thermal conductivity was, mechanical properties were confirmed to have higher tensile strength and elongation as the particles were smaller and the tissue was denser. After selecting materials in consideration of thermal conductivity and mechanical properties, an appropriate mixing ratio is considered important.

열해석을 이용한 위성 광학탑재체 냉각 장치의 히터설계 (Heater Design of a Cooling Unit for a Satellite Electro-Optical Payload using a Thermal Analysis)

  • 김희경;장수영;최석원
    • 항공우주기술
    • /
    • 제10권2호
    • /
    • pp.20-28
    • /
    • 2011
  • 저궤도 관측위성의 광학탑재체는 궤도에서 임무수행을 뒷받침하는 위성 본체와 열적으로 분리되어 각각 독립된 열제어를 할 수 있도록 개발된다. 광학탑재체는 내부에 작동하는 동안에 높은 발열량으로 순간적으로 온도가 상승하는 부품 박스인 FPA(Focal Plane Assembly)의 열을 외부로 방출하기 위한 히트파이프, 방열판으로 구성된 냉각 장치(Cooling Unit)를 가지고 있다. 이러한 냉각 장치는 고온 조건에서 내부 발열을 빠르게 외부로 방출할 수 있는 히트파이프의 성능과 충분한 면적의 방열판 면적을 확보하도록 설계되어야 하고, 동시에 저온 조건에서 최저 온도 이상을 유지하는 위한 히터설계도 포함해야 한다. 본 연구에서는 먼저 FPA 냉각 장치의 열제어 요구조건과 현재 열설계 기준의 열해석 결과를 통하여 히터설계에 대한 검토와 설계 제한 조건을 분석을 하였다. 또한 열해석을 이용한 효율적이고 경제적인 위성 히터설계 방식을 제시하고, 이것을 FPA 냉각 장치의 히터설계에 적용하여 개선된 히터설계 요소를 찾았다.

화력발전소 부하조절기 자동추동장치에 의한 계통주파수 개선에 관한 연구 (Improvement in Power System Frequency Control by Automatic Follow-up Regulator of Thermal Power Plant)

  • 권욱현;황재호
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.10-17
    • /
    • 1991
  • An improved control method in turbine control system is proposed. By automatic follow-up design, power system frequency may be maintained within prespecified range. Base or half load control is possible by distributing power plant load allotment. Otherwise, diminutive frequency-load control is dine by governor-free operation in power plant. This paper proposes governor-free operation which is automatically followed by load-limitter setter. The condition which limits governor action may be somewhat improved within boiler condition by this idea. This design has been implemented at Samchunpo thermal power plant. The improved practical results are shown.

  • PDF

실시간 플랜트 시뮬레이터를 이용한 우주 열환경 챔버 제어기 개발에 관한 연구 (Study on the application of a realtime simulator to the development of a controller for a space thermal environment chamber)

  • 정무진;신영기;최석원;문귀원;서희준;이상훈;조혁진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.216-221
    • /
    • 2003
  • A thermal vacuum chamber is mainly used to simulate thermal environments of a test satellite in satellite orbits in which daily temperature variations range from 80K to above 400K depending on solar radiation under the vacuum below $10^{-4}$ torr. The test facility is quite complex and consists of expensive parts. So any modification of control software is discouraged in fear of unexpected system failure. The purpose of this study is to develop a realtime dynamics model of the thermal vacuum chamber in view of controller design and simulate its electrical inputs and outputs for interface with a PLC (programmable logic controller). A PLC program that was used in the thermal vacuum chamber is applied to the realtime simulator. The realized simulator dynamics is found to be quite similar to that of the thermal vacuum chamber and serve to an appropriate plant to verify the control performance of a programmed PLC.

  • PDF

히트 파이프가 장착된 정지궤도 위성 패널 열해석 프로그램 개발 (DEVELOPMENT OF THERMAL ANALYSIS PROGRAM FOR HEAT PIPE INSTALLED PANEL OF GEOSTATIONARY SATELLITE)

  • 전형열;기정훈;한조영;채종원
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.416-421
    • /
    • 2010
  • The north and south panel of a geostationary satellite are used for radiator panels to reject internal heat dissipation of electronics units and utilize several heat pipe networks to control the temperatures of units and the satellite within proper ranges. The design of these panels is very important and essential at the conceptual design and preliminary design stage so several thousands of nodes of more are utilized in order to perform thermal analysis of panel. Generating a large number of nodes(meshes) of the panel takes time and is tedious work because the mesh can be easily changed and updated by locations of units and heat pipes. Also the detailed panel model can not be integrated into spacecraft thermal model due to its node size and limitation of commercial satellite thermal analysis program. Thus development of a program was required in order to generate detailed panel model, to perform thermal analysis and to make a reduced panel model for the integration to the satellite thermal model. This paper describes the development and the verification of panel thermal analysis program with ist main modules and its main functions.

  • PDF

정지궤도위성 위성체패널 열해석 프로그램 개발 (DEVELOPMENT OF THERMAL ANALYSIS PROGRAM FOR GEOSTATIONARY SATELLITE PANEL)

  • 전형열;김정훈;한조영;채종원
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.66-72
    • /
    • 2010
  • The north and south panel of a geostationary satellite are used for radiator panels to reject internal heat and utilize several heat pipe networks to control the temperatures of units and the main structures of satellite within proper ranges. The design of these panels is very important and essential at the conceptual design and preliminary satellite design stage, so several thousands of nodes or more are utilized in order to perform detailed thermal analysis of panel. Generating a large number of panel nodes takes time and is tedious work because the nodes can be easily changed and updated by locations of units and heat pipes. Also the detailed panel model can not be integrated into spacecraft thermal model due to its node size and limitation of commercial satellite thermal analysis program. Thus development of a program was required to generate a detailed panel model, to perform thermal analysis and to make a reduced panel model for the integration to the satellite thermal model. This paper describes the development and the verification of the panel thermal analysis program with its main modules and functions.

매스콘크리트의 수화열에 관한 해석 및 온도균열 제어방안 연구 (Thermal Stress Analysis and Crack Control on the Heat of Hydration of Mass Concrete)

  • 조선규;서석구;홍규선;윤철균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.264-269
    • /
    • 1996
  • Thermal cracks are occurred when thermal stress due to the hydration of cement exceeds the tensile strength of concrete. In this study, the thermal stresses are investigated at the massive concrete like an anchorage of suspension bridge. The thermal crack can be controlled by considering the placing height, concrete type, pre-cooling and pipe cooling in the design stage.

  • PDF

미숙아의 머리 및 발 보온이 출생초기 체중에 미치는 영향 (The Influence of Thermal Head and Feet Support on Early Stage Weight Gain in Premature Neonates)

  • 백승남;홍혜성;성미혜;조결자;위현주
    • Child Health Nursing Research
    • /
    • 제6권3호
    • /
    • pp.397-410
    • /
    • 2000
  • This is a nonequivalent control group pretest- posttest design in quasi experimental basis to assess how the thermal head and feet support influences on early stage weight gain in premature neonates. The clients were selected among the premature infants with the weight under 2000gms and with the gestational period under 37 weeks, admitted over 15 days in K university hospital, Seoul. The control group of 29 were selected from January 1998 to August 1998, who were without head and feet thermal support, and the experimental group of 30 were selected from September 1998 to May 1999, who were with the two thermal interventions. The results of the study follow, 1.The experimental group with thermal interventions showed more weight gain than the control group without thermal interven- tions, which was statistically significant between the two groups. 2.The physiological weight loss after birth showed less in the experimental group than in the control group. 3.The recovery of the birth weight after the physiologic weight loss showed no statistical difference between the experimental group and the control group. Consequently, the thermal head and feet supportive nursing intervention could be applied as a nursing intervention program to help the premature neonates' development. With the results above we should like to suggest the following: 1) A continuous application in the practice of our thermal supportive intervention for the premature neonates, a development of the content through evaluation, and a comparision of the results through a long time study. 2) A neccessity of deveopment of various study and cross comparision. 3) A neccessity of multi-angular study on the premature infants' characteristics influencing the thermal therapy and the study of the individual differences of the clients.

  • PDF