Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

A STUDY ON THE MECHANICAL CHARACTERISTICS OF RESISTANCE MULTI-SPOT WELDED JOINTS WITH PITCH LENGTH

  • Bang, Han-Sur;Bang, Hee-Seon;Joo, Sung-Min;Chang, Woong-Seong;Lee, Chang-Woo
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.809-815
    • /
    • 2002
  • For clarifying the mechanical phenomena of thermal elasto-plastic behavior on the multi-spot welded joints, this study has tried to carry out three-dimensional thermal elasto-plastic analysis on them. However, because the shape of multi-spot welded joints is not axi-symmetric, unlike the case of single-spot welded joint, the solution domain for simulation should be three-dimensional. Therefore, in this paper, from the results analyzed using the developed the three dimensional unstationary heat conduction and thermal elasto-plastic programs by an iso-parametric finite element method, mechanical characteristics and their production mechanism on single- and multispot welded joints were clarified. Moreover, effects of pitch length on temperature, welding residual stresses and plastic strain of multi-spot welded joints were evaluated, indicating that a pitch of 30mm was advantageous compared to a pitch of 15mm.

  • PDF

복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극 (An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber)

  • 김영민;박성제;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

Heat Transfer Characteristics of Aluminium and FeCrAlY Foam

  • Jin, Meihua;Kim, Pil-Hwan;Lee, Hae-Jong;Jeong, Hyo-Min;Chung, Han-Shik
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.395-401
    • /
    • 2008
  • Since metallic foam will increase the performance of heat exchanger, it have caused many researcher's attention recently. Our research base on the model that metallic foams applied to heat exchanger. In this case, there is three kind of heat transfer mechanisms, heat conduction in fibers, heat transfer by conduction in fluid phase, and internal heat change between solid and fluid phases. In this paper we study both the hydraulic and thermal aspect performance. Pressure drop along air flow direction will be presented. As thermal aspect, we first discuss the acceptance of applying thermal equilibrium among the two phases. then to calculate the dimensionless temperature profile, the heat transfer coefficient and Nu number in 14 metallic foams(7 Aluminium foams, 7 FeCrAlY foams). All these discussion is based on the same velocity u=2 m/s.

  • PDF

고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구 (Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor)

  • 서상규;함희철;강윤구
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.521-528
    • /
    • 2017
  • 본 논문에서는 고체 로켓 추진기관에서 내열재 및 단열재로 사용되는 실리카/페놀릭 복합재료의 열 반응을 고려한 열전도 수치해석을 수행하였다. 고체 로켓 추진기관의 연소 중 실리카/페놀릭의 삭마와 열분해 과정을 고려한 열전도 해석을 위해 1차원 유한차분법을 이용하여 계산을 수행하였다. 노즐벽에서의 경계조건은 대류열전달계수를 고려하였으며, 이는 적분방정식을 이용하여 계산하였다. 삭마두께 및 숯깊이 해석결과는 목삽입재 평가 모터인 TPEM-10을 이용한 시험결과와 비교분석하였으며, 잘 일치하는 것을 확인할 수 있었다.

  • PDF

고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구 (Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor)

  • 서상규;함희철;강윤구
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.76-84
    • /
    • 2018
  • 본 논문에서는 고체 로켓 추진기관에서 내열재 및 단열재로 사용되는 실리카/페놀릭 복합재료의 열반응을 고려한 열전도 수치해석을 수행하였다. 고체 로켓 추진기관의 연소 중 실리카/페놀릭의 삭마와 열분해 과정을 고려한 열전도 해석을 위해 1차원 유한차분법을 이용하여 계산을 수행하였다. 노즐벽에서의 경계조건은 대류열전달계수를 고려하였으며, 이는 적분방정식을 이용하여 계산하였다. 삭마두께 및 숯깊이 해석결과는 목삽입재 평가 모터인 TPEM-10을 이용한 시험결과와 비교분석하였으며, 잘 일치하는 것을 확인할 수 있었다.

복사 차폐막이 설치된 극저온 용기의 열부하 특성에 관한 실험적 연구 (An Experimental Study on the Thermal Load of a Cryochamber with Radiation Shields)

  • 김영민;강병하;박성제
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.11-16
    • /
    • 2008
  • Infrared (IR) detectors are widely used for such applications as thermoelastic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal load of a cryochamber is attributed to the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector cryochamber with a radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation.

열변형으로 인한 틸팅패드 저널베어링의 예압 변화 (Thermal Deformation Induced Preload Changein the Tilting Pad Journal Bearing)

  • 서준호;황철호
    • Tribology and Lubricants
    • /
    • 제32권1호
    • /
    • pp.1-8
    • /
    • 2016
  • This paper focuses on the thermal deformation induced preload change in the tilting pad journal bearing, using a three-dimensional (3D) thermo-hydro-dynamic (THD) approach. Preload is considered as a critical factor in designing the tilting pad journal bearing. The initial preload measured under nil external load and nil thermal gradient is influenced by two factors, namely, the thermal deformation and elastic deformation. Thermal deformation is due to a temperature distribution in the bearing pads, whereas the elastic deformation is due to fluid forces acting on the pads. This study focuses on the changes induced in preload and film clearance due to thermal deformation. The generalized Reynolds equation is used to evaluate the force of the fluid and the 3D energy equation is used to calculate the temperature of the lubricant. The abovementioned equations are combined by establishing a relationship between viscosity and temperature. The heat transfer within the bearing pads, the lubricant, and the spinning journal is calculated using the heat flux boundary condition. The 3D Finite Element Method (FEM) is used in modeling the (1) heat conduction in the spinning journal and bearing pads, (2) thermal gradient induced thermal distortion of the spinning journal and pads, and (3) viscous shearing, and heat conduction and convection in a thin film. This evaluation method has an increased fidelity, and it can prove to be a cost-effective tool that can be used by designers to predict the dynamic behavior of a bearing.

Hot carrier induced carrier transport property on InAs nanowires

  • Kim, Taeok;Park, Sungjin;Kang, Hang-Kyu;Bae, Jungmin;Cho, M.H.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.362.1-362.1
    • /
    • 2016
  • InAs nanowires were synthesized by a vapor-liquid-solid method with InAs powder. The composition and crystalline structure of nanowires were confirmed by energy-dispersive spectroscopy (EDS) and high resolution transmission electron microscopy (HRTEM), respectively. The thermal conduction of nanowires was investigated by the optical method using Raman spectroscopy: i.e., the local temperature on nanowire was determined by laser heating. As temperature increased, the Raman peaks are shifted to low frequency and broadened. The temperature dependent Raman scattering experiments was realized on InAs nanowires with different percentages of zinc-blende and wurtzite structure. The temperature dependence on the nanowire structure has been successfully obtained: the phonon scattering was more increased in InAs heretostructure nanowires, compared to the InAs nanowires with homostructure. The result strongly suggests that the thermal conduction can be effectively controlled by ordered interface without any decrease in electrical conduction.

  • PDF

기존문헌조사에 의한 바닥난방의 인체영향에 관한 연구 (A review on the effect of a floor heating system on the human body)

  • 최영식
    • 한국주거학회논문집
    • /
    • 제3권1호
    • /
    • pp.85-92
    • /
    • 1992
  • A floor system have played a major part in the living in Korean house. It is an essential element in the residential houses. Uufortunately, a design method of the floor heating system for the human thereat comfort has not established in Korea system. This paper aims to review the previous researches to find the issue for the futher study of comfort floor heating design. The following results were obtained: 1) Nevins et at conducted experiments on the effect of the comfortable of floor and air temperatures on the psychological responses by a large number of subjects. Its objective was to find the combined condition to obtain thermal comfort for sedentary posture.7here has never been researches regarding a sitting Person on the heated floor. 2) Some investigation in Japan on the effect of floor heating system on a sitting person on the floor have been conducted for these years, but they are net based on the human heat balance but on only psychological responses. 3) Hirayama et al developed an indication method of the effect of heat conduction on the sedentary person.4) There are few researches on the human thermal comfort compared whth indoor environmental researches on mechanical controls in Korea. Thus, the further study on the followings in needed the estimaiing of heat conduction between tile hunman body and a floor, developing an index expressed the combined effect of convection, radiation and conduction and its associated experiments.