• Title/Summary/Keyword: thermal camera

Search Result 520, Processing Time 0.026 seconds

Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image (적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석)

  • Cho, Jai-Wan;Hong, Seok-Boong;Koo, In-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.12
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.

A Study on the Bubble Flow in the Gas-Liquid Plume (기-액 기둥에서 기포유동에 관한 연구)

  • Seo, Dong-Pyo;Hong, Myung-Seok;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2105-2108
    • /
    • 2003
  • The characteristics of upward bubble flow were experimentally investigated in a liquid bath. In the present study, a thermal-infrared camera and high speed CCO camera were used to measure their temperature and local rising velocity, respectively. Heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. The rising velocity of bubble was calculated for two different experimental conditions: 1) bubble flow without kinetic energy 2) with kinetic energy. Bubble flow without kinetic energy starts to undergo the effect of inertia force 10cm away from the nozzle. Whereas, kinetic energy is dominant before 30 cm away from the nozzle in bubble flow, but after this point, kinetic energy and inertial force are applied on bubble flow at the same time.

  • PDF

VISUAL MEASUREMENT METHOD USING A CIRCULAR GROOVE IMAGE FOR MEASURING INTERNAL DEFECTS OF PIPES IN NUCLEAR POWER PLANT

  • Choi, Young-Soo;Jeong, Kyung-Min;Lee, Sung-Uk;Jung, Seung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.419-428
    • /
    • 2008
  • During the overhaul period of nuclear power plants in Korea, an ROV(Remotely Operated Vehicle) enters the cold-leg pipes connected with the reactor to examine the state of the thermal sleeves and their positions in the safety injection nozzles. To measure the positions of the thermal sleeves or scratches with video images recorded during the examination, time-varying camera parameters should be known, such as the focal length and principal points used for the capturing each video image. In this paper, we propose a camera calibration and measurement scheme by using a single image containing two circular grooves of a cylindrical nozzle whose radius and distance are known.

Fast Defect Detection of PCB using Ultrasound Thermography (초음파 서모그라피를 이용한 빠른 PCB 결함 검출)

  • Cho, Jai-Wan;Jung, Hyun-Kyu;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.273-275
    • /
    • 2005
  • Active thermography is being used since several years for remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements were performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

  • PDF

Thermal Infrared Image Analysis for Breast Cancer Detection

  • Min, Sedong;Heo, Jiyoung;Kong, Youngsun;Nam, Yunyoung;Ley, Preap;Jung, Bong-Keun;Oh, Dongik;Shin, Wonhan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.1134-1147
    • /
    • 2017
  • With the rise in popularity of photographic and video cameras, an increasing number of fields are now using thermal imaging cameras. One such application is in the diagnosis of breast cancer, as thermal imaging provides a low-cost and noninvasive method. Thermal imaging is particularly safe for pregnant women, and those with large, dense, or sensitive breasts. In addition, excessive doses of radiation, which may be used in traditional methods of breast cancer detection, can increase the risk of cancer. This paper presents one method of breast cancer detection. Breast images were taken using a thermal camera, with preliminary experiments conducted on Cambodian women. Then the experimental results were analyzed and compared using Shannon entropy and logistic regression.

Design Verification of Thermal Control Subsystem for EOS-C Ver.3.0 using STM Thermal Vacuum Test Result (STM 열진공 시험 결과를 이용한 EOS-C Ver.3.0 열제어계 설계 검증)

  • Chang, Jin-Soo;Yang, Seung-Uk;Jeong, Yun-Hwang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1232-1239
    • /
    • 2010
  • A high-resolution electro-optical camera (EOS-C Ver.3.0), the mission payload of an Earth observation satellite, is under development in Satrec Initiative. We designed this system to give improved thermal performance compared with the EOS-C Ver.2.0 which is the main payload of DubaiSat-1 by optimizing the active and passive thermal control design. We developed the Structural-Thermal Model (STM) and verified the design margin by performing the qualification level thermal vacuum test. We also conducted the verification of its Thermal Mathematical Model (TMM) through the thermal balance test. As a result, it was confirmed that TMM faithfully represents the thermal characteristics of the EOS-C Ver.3.0.

A Study on Welding Union by Welding Fume Shape Measurement (용접 Fume 형상 측정에 따른 용접 결합에 관한 연구)

  • Kim J.Y.;Choi C.J.;Kwak N.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.35-36
    • /
    • 2006
  • In Nd:YAG laser welding, evaluation methods of welding flaw are various. But, the method due to fume shape is difficult to classification of welding flaw. The Nd:YAG laser process is known to have high speed and deep penetration capability to become one of the most advanced welding technologies. At the present time, some methods are studied for measurement of fume shape by using high-speed camera and photo diode. This paper describes the machining characteristics of SM45C carbon steel welding by use of an Nd:YAG laser. In spite of its good mechanical characteristics, SM45C carbon steel has a high carbon contents and suffers a limitation in the industrial application due to the poor welding properties. In this study, fume shape was measured by infrared thermal camera that is non-contact/non-destructive thermal measurement equipment through change of laser generating power, speed, focus. Weld was performed on bead-on method. Measurement results are compared as two equipments. Here, two results are composed of measurement results of fume quantities due to fume shape by infrared thermal camera and inspection results of weld bead include weld flaws by ultrasonic inspector.

  • PDF

Thermographic assessment on temperature change of skin surface in frame fitting point (열화상 카메라를 활용한 frame fitting point의 표면 온도 분석)

  • Joo, Byung Hyuk;Park, Chang Won
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.1
    • /
    • pp.1462-1468
    • /
    • 2021
  • Purpose; The purpose of this study is to objectively identify and quantify the wearer's feelings of wearing glasses. Methods: The temperature of the skin on the nose ridges and ear, and the area where the glasses were seated, was measured using a thermal imaging camera. Results: Before wearing the glasses, the temperature of the skin surface on the nasal ridge was 34.908 ± 0.875 ℃ and the temperature of the ear region was determined as 31.981 ± 0.549 ℃. The changed temperature measured at 5 minutes later after taking off the glasses showed that the nasal ridge was determined as 35.467 ± 0.342 ℃ and the ear area was determined as 32.994 ± 0.412 ℃ (p<0.05). Conclusions: In this experiment, it was revealed that the glasses cause discomfort and heat in the fitting area. It was the first attempt to study objectively and scientifically. Analysis of frame fitting points by using thermal camera is expected to be helpful when consulting a sensitive person about changes in the fit of glasses.

Forest Fire Response System Using Thermal Imaging Camera (열화상카메라를 이용한 산불 화재 대응시스템 연구)

  • Yoon, Won-Sub;Kim, Yeon-Kyu;Kim, Seung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.927-935
    • /
    • 2021
  • This study conducted a study to improve the problems of the existing fire sensor system. In the case of the existing system, it took more than 3 minutes to detect a fire even at a short distance, making it difficult to extinguish the initial fire. In order to improve these problems, in this study, a fire detection system using an infrared thermal imaging camera was studied. The infrared image-based fire detection system is relatively wide and can detect fire over a long distance, so it has the advantage of being applicable to many fire detection systems. As a result of conducting a field test using the fire detection system, a fire that occurred about 2 km ahead was detected within about 10 seconds. Since the fire detection function of this system can detect within 10 seconds from a distance of about 2 km, it was applicable to forest fires that occur frequently in spring and autumn.

Development and Design Verification of Thermal Control Subsystem for EOS-C Ver.3.0 Flight Model (EOS-C Ver.3.0 비행모델의 열제어계 개발 및 설계 검증)

  • Chang, Jin-Soo;Yang, Seung-Uk;Kim, Ee-Eul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.10
    • /
    • pp.872-881
    • /
    • 2012
  • The Flight Model (FM) of a high-resolution electro-optical camera (EOS-C Ver.3.0), the mission payload of an Earth observation satellite, was successfully developed by Satrec Initiative. We designed it to give improved thermal representatives compared with the Structural-Thermal Model (STM) by optimizing the thermal characteristics based on the STM thermal vacuum test results. We developed the FM and verified the workmanship by performing the acceptance level thermal vacuum test. We also conducted the verification of its Thermal Mathematical Model (TMM) by the thermal balance test. As the result, it was confirmed that TMM faithfully represents the thermal characteristics of the EOS-C Ver.3.0 FM.