• Title/Summary/Keyword: thermal NO

Search Result 2,443, Processing Time 0.025 seconds

Effect of Reduced Valve Overlap on Emission Characteristics of Hydrogen-Compressed Natural Gas Engine (수소-천연가스엔진에서 밸브오버랩 감소가 배기특성에 미치는 영향)

  • Lee, Sungwon;Lim, Gihun;Park, Cheolwoong;Choi, Young;Kim, Changgi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In order to meet the current emission regulations (EURO-6), it is necessary to significantly reduce $CH_4$ and $NO_X$ emissions. This study investigated the effect of a reduction in the valve overlap on the combustion and emission characteristics of a hydrogen-compressed natural gas engine under a part-load operating condition. The combustion and emission characteristics were analyzed for each fuel using the original camshaft and an altered camshaft with reduced valve overlap. The results showed that the thermal efficiency was decreased and the fuel flow was increased when using the altered camshaft. The $CO_2$ and $CH_4$ emissions were increased as a result of the reduced thermal efficiency. Under lean operating conditions, the $NO_X$ emission was decreased compared with one of the conventional camshaft. Thus, under the same fuels and operating conditions, it had a harmful influence on the emission characteristics and thermal efficiency.

A Study of Simultaneous Reaction for NOx, Soot and Thermal Shock according to Pt Catalyst's Supports (담체에 따른 Pt 촉매의 NOx, soot 동시 반응특성과 열충격에 관한 연구)

  • Kim, Sung Su;Park, Kwang Hee;Bae, Se Hyun;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.437-442
    • /
    • 2009
  • In this work, thermal shock and simultaneous removal reaction for NOx, soot over Pt catalysts using $TiO_2$, $Al_2O_3$ as support were studied. The catalytic reaction test for NOx and soot were also performed independently and simultaneously, as a result, it showed different NOx removal efficiency and soot oxidation rate according to support and phase, and the onset temperature of soot oxidation has correlation to NOx removal efficiency for the catalyst. The onset temperature of soot oxidation shifted to lower temperature by generated $NO_2$ at the simultaneous reaction for NOx and soot. Also Pt/$TiO_2$ catalyst is more affected than Pt/$Al_2O_3$ on NOx removal efficiency caused by thermal shock while Pt sintering effect induced to reduce the performance on soot oxidation rate for all catalysts.

Operating Characteristics of Molded Case Circuit Breakers by Harmonic Currents (고조파 전류에 의한 배선용 차단기 동작 특성)

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.68-74
    • /
    • 2006
  • Malfunction and nuisance tripping of molded case circuit breaker(MCCB) caused by harmonic currents have been reported. But no data is available on the behavior of MCCB under harmonic currents. This paper tested the effects of harmonic currents on four common types of MCCB(thermal, thermal magnetic, magnetic and electronic types). Results of experiment detected no nuisance tripping with any of the breakers tested under test currents, included harmonic current, below rated currents. Additionally it was found that varying harmonic loading conditions did not affect manufacturer specified trip times for thermal only and thermal magnetic circuit breakers. However, under overloaded conditions, trip times of the magnetic only circuit breakers were gradually slowed according to increasing of harmonic currents, and it could cause hazardous overheating of cables. So, the use of magnetic only circuit breakers in the place harmonic currents we serious must be avoided.

Correlation Analysis between HIVD of L-spine MRI and Digital Infrared Thermal Image (DITI) on the Patients of LBP Who Visit Korean Medicine Hospital (한방병원에 요통, 하지방사통으로 내원한 환자 236명에서 MRI상 추간판 탈출증과 적외선 체열 검사(DITI)와의 연관성 분석)

  • Kim, Gil-Hwan;Kwon, Ok-Jun;Joo, Young-Kuk;Song, Seung-Bae;Kim, Doo-Ri;Choi, Young-Jun;Shin, Soo-Ji
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.3
    • /
    • pp.107-115
    • /
    • 2017
  • Objectives This study is planned to classify correlation between HIVD of L-spine MRI and Digital Infrared Thermal Image (DITI). Methods We measured the temperature of both leg whose 120 men and 116 women patients with lumbar pain in Bucheon Jaseng Korean Medicine Hospital. And We use Magnetic Resonance Imaging (MRI) for classifying the patients who has lumbar intervertebral disc or not. Results 1) There was no statistical relation between difference of both leg's temperature and gender (p>0.05). 2) There was meaningful statistical relation between difference of both leg's temperature and age (p<0.05). 3) There was meaningful statistical relation between direction of HIVD of L-spine and direction of temperature reduction. 4) There was meaningful statistical relation between the severity of HIVD of L5/S1 and degree of temperature reduction. But there was no statistical relation between the severity of HIVD of L3/4, L4/5 and degree of temperature reduction. Conclusions We can use Digital Infrared thermal image (DITI) on low back pain patients for diagnosis. But we should not use DITI alone. DITI has limit in diagnosis.

Effect of La and Si Addition on Thermal Stabilization of Alumina (La 및 Si 첨가에 의한 알루미나의 열안정화 효과)

  • Lee, Chae-Hyun;Lim, Dae-Young;Kim, Jong-Ock;Seo, Doo-Won;Han, Moon-Hee
    • The Journal of Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.215-222
    • /
    • 1998
  • The effect of La and Si addition of the thermal stabilization of $\gamma-alumina$ powers have been studied. Reagent grade $La(NO_3)_3{\cdot}6H_2O$ and $Si(OC_2H_5)_4$ were used as starting materials. These additives were introduced by wet impregnation method. Both La and Si additives suppressed the sintering of alumina and were found to be good thermal stabilizers of $\gamma-alumina$. Especially, Si drastically suppressed the phase transition of alumina at high temperatures. The major mechanisms for the thermal stabilization of alumina were seemed to be new phase formation and retardation of surface diffusion by addition of La or Si into alumina matrix.

  • PDF

Thermal Stabilization of Alumina by Ba Addition (Ba 첨가에 의한 알루미나의 열 안정화 효과)

  • Seo, Doo-Won;Han, Moon-Hee;Lee, Chae-Hyun
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.139-145
    • /
    • 1997
  • The effect of Ba addition on the thermal stabilization of $\gamma$-$Al_2O_3$ powders were studied. Ba additive was introduced into $\gamma$-$Al_2O_3$ powders by wet impregnation of $Ba(No_3)_3$.$6H_2O$. Ba additive was proved to be effective on the thermal stabilization of $\gamma$-$Al_2O_3$ powders by suppression of sintering. The optimum content of Ba was determined by 5 mol%, through the calcinations temperature range. It is suggested that the main reason of thermal stabilizaton is the substitution effect of large $Ba^{2+}$ ions into the $\Al^{3+}$ sites, which suppressed the surface diffusion of $\Al^{3+}$ ions.

  • PDF

The Effect of Punctal Occlusion with Thermal Cautery after Third Eyelid Resection in Dogs (개에서 제3안검 제거 후 전기소작법을 이용한 누점폐쇄 효과)

  • Choi Jang-Yoon;Park Hyun-Jeong;Lee Joo-Myoung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.50-54
    • /
    • 2006
  • To evaluate the effect of punctal occlusion on tear preservation after third eyelid resection, 10 eyes were operated in dogs and observed changes in tear preservation using Schirmer tear test (STT). Punctal occlusion was performed on five healthy dogs with no clinical sings of ocular irritation and no history of dry eye syndrome. The STT was performed for 10 days before surgery, and on the day 0, 1, 3, 5, 7, 9, 11, 13, 17, 21, 25, and 30 after third eyelid resection. The mean STT was $17.4{\pm}0.15$ mm/min($mean{\pm}SEM$) for 10 days before surgery. And, it was $11.5{\pm}0.55$mm/min for 30 days after surgery in puntal occlusion(PO) group. The mean STT was $17.3{\pm}0.32$ mm/min for 10 days before surgery. And, it was more decreased to $6.5{\pm}0.60$ mm/min for 30 days after surgery in control group. The paired t-test was performed. Mean STT after the third eyelid resection was higher in PO group than that of control throughout experimental period (p<0.05). In summary, the effect of thermal punctal occlusion significantly increased on the tear preservation by $28.86{\pm}7.96%$. These results suggest that application of thermal punctal occulsion in dry eye syndrome will promote tear preservation.

Plasma Upflows and Microwave Emission in Hot Supra-arcade Structure associated with M1.6 Limb Flare

  • Kim, Sujin;Shibasaki, Kiyoto;Bain, Hazel M.;Cho, Kyung-Suk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.74.1-74.1
    • /
    • 2014
  • We have investigated a supra-arcade structure associated with an M1.6 flare, which occurred on the south-east limb in the 4th of November 2010. It is ob- served in extreme ultraviolet (EUV) with the Atmospheric Imaging Assembly (AIA) onboard the Solar Dynamics Observatory (SDO), microwaves at 17 and 34 GHz with the Nobeyama Radioheliograph (NoRH), and soft X-rays of 8-20 keV with the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI). Interestingly, we found exceptional properties of the supra-arcade thermal plasma from the AIA 131 A and the NoRH: 1) plasma upflows along large coronal loops and 2) enhancing microwave emission. RHESSI detected two soft X-ray sources, a broad one in the middle of supra-arcade structure and a bright one just above the flare-arcade. We estimated the number density and thermal energy for these two source regions during the decay phase of the flare. In the supra-arcade source, we found that there were increases of the thermal energy and the density at the early and the last stages, respectively. On the contrary, the density and thermal energy of the source on the top of the flare-arcade decreases throughout. The observed upflows imply that there is continuous energy supply into the supra- arcade structure from below during the decay phase of the flare. It is hard to be explained by the standard flare model in which the energy release site is located high in corona. Thus, we suggest that the potential candidate as the energy source for the hot supra-arcade structure is the flare-arcade which has exhibited a predominant emission throughout.

  • PDF

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

Combustion Characteristics of a Hot Water Boiler System Convertibly Fueled by Rice Husk and Heavy Oil - Heavy Oil Combustion Characteristics -

  • Kim, Myoung Ho;Kim, Dong Sun;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.306-311
    • /
    • 2013
  • Purpose: With the ever-rising energy prices, thermal energy heavily consuming facilities of the agricultural sector such as commercialized greenhouses and large-scale Rice Processing Complexes (RPCs) need to cut down their energy cost if they must run profitable businesses continually. One possible way to reduce their energy cost is to utilize combustible agricultural by-products or low-price oil instead of light oil as the fuel for their boiler systems. This study aims to analyze the heavy oil combustion characteristics of a newly developed hot water boiler system that can use both rice husk and heavy oil as its fuel convertibly. Methods: Heavy oil combustion experiments were conducted in this study employing four fuel feed rates (7.6, 8.5, 9.5, 11.4 $l/h$) at a combustion furnace vacuum pressure of 500 Pa and with four combustion furnace vacuum pressures (375, 500, 625, 750 Pa) at fuel feed rates of 9.5 and 11.4 $l/h$. Temperatures at five locations inside the combustion furnace and 20 additional locations throughout the whole hot water boiler system were measured to ascertain the combustion characteristics of the heavy oil. From the temperature measurement data, the thermal efficiency of the system was calculated. Flue gas smoke density and concentrations of air-polluting components in the flue gas were also measured by a gas analyzer. Results: As the fuel feed rate or combustion furnace vacuum pressure increased, the average temperature in the combustion furnace decreased but the thermal efficiency of the system showed no distinctive change. On the other hand, the thermal efficiency of the system was inversely proportionally to the vacuum level in the furnace. For all experimental conditions, the thermal efficiency remained in the range of 80.1-89.6%. The CO concentration in the flue gas was negligibly low. The NO and $SO_2$ concentration as well as the smoke density met the legal requirements. Conclusions: Considering the combustion temperature characteristics, thermal efficiency, and flue gas composition, the optimal combustion condition of the system seemed to be either the fuel feed rate of 9.5 $l/h$ with a combustion furnace vacuum pressure of 375 Pa or a fuel feed rate of 11.4 $l/h$ with a furnace vacuum pressure between 500 Pa and 625 Pa.