A STUDY ON THERMAL MODEL REDUCTION ALGORITHM FOR SATELLITE PANEL (인공위성 패널 열해석모델 간소화 알고리즘 연구)

  • Kim, Jung-Hoon;Jun, Hyoung Yoll;Kim, Seung Jo
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.9-15
    • /
    • 2012
  • Thermal model reduction algorithms and techniques are introduced to condense a huge satellite panel thermal model into the simplified model on the purpose of calculating the thermal responses of a satellite on orbit. Guyan condensation algorithm with the substitution matrix manipulation is developed and the mathematical procedure is depicted step by step. A block-form LU decomposition method is also invited to compare the developed algorithm. The constructed reduced thermal model induced from the detailed model based on a real satellite panel is satisfying the correlation criterion of ${\pm}2^{\circ}C$ for the validity accuracy. Guyan condensation algorithm is superior to the block-form LU decomposition method on computation time.

Design of Filament Wound Composite Tubes under Thermal Contraction (열수축을 하는 필라멘트 와인딩 복합재료 관의 설계)

  • 정태은;신효철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2407-2417
    • /
    • 1993
  • Thermal deformations and stresses due to temperature changes are the serious problems in cryogenic structures such as the torque tube in a superconducting generator, In this paper, the equations of thermal expansion coefficients expressed only by material properties and winding angles are derived for the filament wound composite tubes. The experimental results of thermal contraction of CFRP tubes are compared with those from theoretical approach. Composite tubes with optimally regulated thermal expansion coefficient are designed on the basis of the study for the torque tube in the superconducting generator with temperature distributions varying from 300K to 4.2 K. The filament winding angle of composites resisting thermal stresses properly is sought by the finite element method using layered shell elements. The results show that the composite tubes designed for the requirements in cryogenic environments can effectively cope with the thermal stress problem.

Thermal Characteristics of Domestic Solar Collector for Low-Temperature Applications (국내 저온용 집열기의 열성능 특성)

  • Kim, Jeong-Bae;Rhie, Soon-Myeong;Yoon, Eung-Sang;Lee, Jin-Kook;Joo, Moon-Chang;Baek, Nam-Choon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.215-220
    • /
    • 2008
  • This study shows the results on thermal performance test with domestic solar collector for low-temperature applications using KS, then reveals the efficiency difference between KS and EN standard. Using the test results, this study presents the status of thermal performance with domestic solar collector including flat-plate, single evacuated, and double evacuated (with mirror or U-tube) solar collector.

  • PDF

Experimental Investigation of Thermal Stress Cracks in Mechanical Face Seals (기계평면시일의 열응력 크랙에 관한 실험적 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.79-84
    • /
    • 1996
  • One of the greatest dangers in mechanical face seals is the formation of heat checking and thermal stress cracks on the sliding surfaces. These thermal distortions due to non-uniform heating lead to increase the leakage of the sealed fluids and wear, and with balance of the seal can cause the seal faces to part. In this study heat checking and thermal stress cracks are investigated experimentally. These thermal distortions are explained using the thermal models of the conatct geometries between the seal ring and the seal seat. To overcome these thermal problems, the thermohydrodynamic seal is presented. The newly developed mechanical seal may substantially reduce the friction torque, frictional heating which causes heat checking and thermal stress cracks, and wear.

Development of the Soil Thermal Property and Temperature Measurement System for the Real-time Ampacity Estimation of Underground Power Cables (실시간 지중 전력케이블 용량 평가를 위한 토양 열 특성 및 온도 측정 시스템 개발)

  • Jeong, Seong-Hwan;Kim, Dae-Kyeong;Choi, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.22-24
    • /
    • 2002
  • This paper introduces the real-time soil thermal property analyzer and temperature measuring system which is combined with radio telecommunication technique. To measure the thermal parameters in real-time, the radio telecommunication technique are used the personal communication service (PCS) which is in the world-wide serviced commercially firstly by CDMA. The thermal property analyzer has an ability of measuring thermal resistivity, thermal diffusivity and thermal stability. To estimate the soil thermal properties, the curve fitting algorithm by means of the least square method are used. TCP/IP protocol and MTM are used to install the real-time soil thermal property and temperature measurement system at multiple locations along routes of the underground power cables and to reduce the cost of telecommunication.

  • PDF

Prediction of Thermal conductivities of 3-D braided glass/epoxy composites using a thermal-electrical analogy (3차원 브레이드 유리섬유/에폭시 복합재료의 열전도도 예측에 관한 연구)

  • 정혁진;강태진;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.52-55
    • /
    • 2002
  • This paper examines the effective thermal conductivity of 3-D braided glass/epoxy composites. 3-D braided composites have a number of advantage over conventional laminate composites, including through-thickness reinforcement, and high damage tolerance and processability. The thermal properties of composites depend primarily on the microstructure of the braided preform and properties of constituent materials. A thermal resistance network model based on structure of the braided preform is proposed by using thermal-electrical analogy. In order to affirm the applicability theses solutions, thermal conductivities of 3-D braided glass/epoxy composites are measured

  • PDF

Thermal Stress Intensity Factors for Partially Insulated Interface Crack under Uniform Heat Flow (부분 열유동이 있는 접합 경계면균열의 열응력세기계수 결정)

  • 이강용;박상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1705-1712
    • /
    • 1994
  • Hilbert problems are derived to evaluate thermal stress intensity factors for a partially insulated crack subjected to vertically uniform heat flow in infinite bonded dissimilar materials. In case of fully insulated crack surface, the present solutions of thermal stress intensity factors are reduced into the same as the previous results. For the homogeneous material, mode II thermal stress intensity factor only exists. However, in the bonded dissimilar materials, both mode I and II thermal stress intensity factors are obtained. Specially, in this case, mode II thermal stress intensity factor is dominent. Also, thermal stress intensity factors are strongly influenced by the material properties. Thermal stress intensity factors decrease when the degree of insulation decreases.

Asymmetric Thermal-Mixing Analysis due to Partial Loop Stagnation during Design Basis Accident (원전 설계기준 사고시 냉각재계통 부분정체로 인한 비대칭 열유동 혼합해석)

  • Hwang K. M.;Jin T E.;Kim K. H.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.51-54
    • /
    • 2002
  • When a cold HPSI (High Pressure Safety Injection) fluid associated with an design basis accident, such as LOCA (Loss of Coolant Accident), enters the cold legs of a stagnated primary coolant loop, thermal stratification phenomena will arise due to incomplete mixing. If the stratified flow enters a reactor pressure vessel downcomer, severe thermal stresses are created in a radiation embrittled vessel wall by local overcooling. Previous thermal-mixing analyses have assumed that the thermal stratification phenomena generated in stagnated loop of a partially stagnated coolant loop are neutralized in the vessel downcomer by strong flow from unstagnated loop. On the basis of these reasons, this paper presents the thermal-mixing analysis results in order to identify the fact that the cold plume generated in the vessel downcomer due to the thermal stratification phenomena of the stagnated loop is affected by the strong flow of the unstagnated loop.

  • PDF

Thermal Conductivity Measurement of Grouting Materials for Ground Heat Exchanger Borehole (지중 열교환기 보어홀 그라우팅 재료의 열전도도 측정)

  • Sohn, Byong-Hu;Shin, Hyun-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.493-500
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity. The quartzite and silica sands produced the largest increases in mixture thermal conductivity, while common masonry and limestone sands produced lower thermal conductivity increases.