• Title/Summary/Keyword: the water quality

Search Result 11,853, Processing Time 0.033 seconds

Water Quality Level of the Living Environmental Standards and Regression Analysis in the Major Tributaries of the Nakdong River (낙동강 주요 지류에서 생활환경 기준 수질 성분의 수질등급 및 회귀분석)

  • Kang, Dong-hwan;So, Yoon-hwan;Park, Kyeong-deok;Kim, Il-kyu;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.28 no.3
    • /
    • pp.357-369
    • /
    • 2019
  • In this study, the water quality components (pH, BOD, COD, TOC, SS, DO, TP) and the water quality, observed for 10 years (2008~2017) in the five tributaries of the Nakdong River with the highest flow rates, were analyzed. Monthly levels of the water quality components were estimated and regression functions were used to quantitatively explain the changes in the BOD and COD components, with respect to the TOC components. The results of analyzing the water quality levels in terms of the living environmental standards show that the lowest water quality was observed midstream (ST-3) and the highest water quality was observed upstream (ST-1 and ST-2). The regression function was estimated to be a linear function in all five tributaries, and the goodness of fit of the function was high upstream (ST-2), midstream (ST-3), and downstream (ST-4). According to the regression analysis using the observation data from 2008~2017, we found that the consumption of dissolved oxygen increased with an increase in organic matter in the major tributaries of the Nakdong River.

Study on the Long-Term Change of Water Quality of the Kumho River (금호강 수질의 장기 변동에 관한 연구)

  • 배준웅;장혜영
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.207-220
    • /
    • 1995
  • In order to study on the long-term change of water quality, water analysis was conducted at 16 sites surrounding the Kumho river system for 11 times from September 1990 to August 1993. Analytical items for the study of water Quality are as follows; water temperature, pH, COD, BOD, DO, SS, electrical conductivity, $NH_3-N$, $NO_2^-N$, NO_3^-N$, $PO_4^{3-}-P$, total-P, hardness, oil and grease, ABS, phenol, zinc, chromium, cadmium, manganese, iron, lead and color. The long-term change of water quality in the Kumho river for the period studied was found that the values of water temperature, electrical conductivity, phenol, $NO_2^-N$ and $NH_3-N$ were increasing and those of COD, BOD, SS, oil and grease, ABS, NO_3^-N$, $PO_4^{3-}-P$, copper, zinc, chromium, cadmium, manganese and lead were decreasing, while those of pH, hardness, iron and manganese were steady.

  • PDF

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

2-Dimensional Model Development for Water Quality Prediction

  • Paik, Do-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.489-497
    • /
    • 2005
  • A numerical method for the mathematical water modeling in 2-dimensional flow has been developed. The model based on a split operator technique, in which, the advection term is calculated using the upwind scheme. The diffusion term is one- dimensionalized and calculated using Crank-Nicholson's implicit finite difference scheme to reduce the numerical errors from large time steps and variable spacings. It also provides a relatively simple and economic method for more accurate simulation of pollutant dispersion. Water depths and flow velocities in the Boreyong reservoir during the normal water periods were predicted by numerical experiments with a 2-dimensional flow model so as to provide current field data for the study of advection and diffusion of pollutants. Developed 2-dimensional water quality model is applied to Boreyong reservoir to simulate a spatial and periodical changes of water quality.

Characteristics of Water Quality and Biological Changes in the Onchun Stream -After the Flowing of the Nakdong River- (낙동강 유지용수 공급 후 온천천의 수질 및 생물변화 특성)

  • Park, Hong-Ki;Son, Jung-Won;Cho, Jin-Tack
    • Journal of Life Science
    • /
    • v.22 no.8
    • /
    • pp.1041-1045
    • /
    • 2012
  • This study investigated the changes caused by diverting water applications at the riverhead of the Onchun Stream via the monitoring of several water quality and biological parameters between 10/09 and 10/10. The analysis indicated that the Onchun Stream distinctly decreased in terms of several water quality parameters, such as BOD, COD, TN, TP, and the concentration of heavy metals as compared to similar values in 2005, before the flowing of the Nakdong River. Especially, BOD showed the 2nd grade of water quality, with an average of 2.0 mg/l at all sites. The species number and standing crops of plankton and benthic macroinvertebrates in the Onchun Stream were also increased. Thus, it was concluded that diverting water from the Nakdong River to the Onchun Stream dramatically improved various environmental indices, such as water quality and biological changes.

Analysis of the Water Quality by Various Gate Operation Effects at Nakdong Estuary Barrier (낙동강하구둑 수문운영에 따른 수질 영향 분석)

  • Lee, Sang Jin;Ryoo, Kyong Sick;Hwang, Man Ha;Lee, Sang Uk
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.651-658
    • /
    • 2008
  • Estuary barrier is a hydraulic structure constructed to supply safely water as protecting chlorine penetration of sea water. However, the barrier brings about a problem which decreases original functions of estuary because hydraulic ecology was disrupted as obstructing natural water exchange between fresh water and sea water. It is important to supply Enough fresh water in the estuary ecosystem. But it is possible to reduce the problems brought from barrier throughout efficient water gate operation of estuary barrier. It was shown in this study that the environmental effect of estuary in Nakdong river was investigated according to the control of water level. Also, the basic information about the effective water gate operation was provided. The analysis results showed that the release rate of estuary was increased about 20% as changing the operational water levels. This helps supplying fresh water durably to the mixing zone. Also, CE-QUAL-W2 model was utilized to assess water quality. The values of BOD and COD were not changed in estuary area. From the result, it was analyzed the effect of water quality according to the water gate operation was not indicated.

Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

Non-point Source Impact Analysis through Linkage of Watershed Model and River Water Quality Model (유역모형과 하천수질모형의 연계를 통한 비점오염원 영향분석)

  • Choi, Hyun Gu;Kim, Dong Il;Kim, Ji Eun;Han, Kun Yeun
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.25-36
    • /
    • 2011
  • In this study, the accurate water quality analysis in rivers, including the non-point source is performed. First of all, watershed model, SWAT(Soil and Water Assessment Tool) was applied to analyze the impact of the non-point source in study area. And then, water quality analysis integrating the point source and the non-point source is implemented using QUALKO model. For more exact simulation, it should be the calibration and verification of variables and parameters which are needed for simulation. In addition, the importance of considering the non-point source was confirmed in river water quality simulation. BOD, TN, TP were analysed, and the results shows that BOD, TN and TP concentration was increased to 16.8%, 8.2% and 25.8% respectively. The more accurate estimate will be carried if use of reliable measurements and watershed simulation be done in models linking process. The suggested technique will improve the accuracy of the water quality analysis. The methodologies presented in this study will contribute to basin-wide water quantity and quality management.

The Corrosion Effect of the Water Pipelines in Buildings according to Drinking Water Quality (수돗물 수질에 따른 옥내급수관 부식에 미치는 영향분석)

  • Yu, Soon-Ju;Park, Su-Jeong;Ahn, Kyung-Hee;Kim, Hyun-Gu;Kim, Chang-Soo;Jung, Il-Rock;Park, Young-Bok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.701-708
    • /
    • 2008
  • As a countermeasure for reduction of corrosion in the delivery and distribution pipes used for tap water, materials for the pipelines in-houses and the effect of water quality on corrosivity of water pipelines were investigated in the distribution system of Han river. As the corrosion index at 6 water purification facilities of Han river, average Langelier Saturation Index (LI) of raw and finished water were -1.0 and -1.4 respectively and average Larson Index (LR) were 9.5 and 9.9, respectively. And also corrosion potential showed corrosivity in finished water (-431~-462 mV) as well as raw water (-426~-447 mV). This results indicate that tap water quality of han river have corrosivity. To understand the corrosivity effect in pipe material used for premise distribution system, water quality of stagnant tap water and tap water were analyzed and the differences between them were calculated. The difference concentration of iron, copper and zinc were $12.9{\mu}g/L$, $31.0{\mu}g/L$ and $45.0{\mu}g/L$ respectively in galvanized steel pipe for use more than 15 years and showed highest concentration. As a result, the control to corrosivity in the water pipelines, corrosivity control treatment in the water purification system can be applied. In advance it is necessary to monitor corrosivity of water quality using corrosive index because corrosivity may differ from the seasonal and regional characteristics and water chemicals dosage. For the future the guideline for corrosion index have to be established.

A Study on Water Purification Effect of Media Block Using Porous Ceramics and Zeolite (다공성 세라믹과 제올라이트를 활용한 수질정화미디어블럭의 효과 연구)

  • Jeon, Sung-yool;Koo, Bon-hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.5
    • /
    • pp.59-66
    • /
    • 2017
  • Preeminent water treatment plans are essential to preserve the water quality of aquatic biotopes. Previous studies have not been sufficient to provide cost-effective maintenance method since they focused only on the purification of deteriorated water that requires a continuous supply of clean water. This study proposes an economical method of water quality maintenance using water treatment media block constructed vertically using porous ceramics, zeolite, and river pebble. The water treatment media block does not require a separate purification area because it functions as a purifier within the ecological pond which can maximize the biotope area. To evaluate the performance of the water treatment media block, we longitudinally tracked the change of water quality indicators (pH, TDS, COND, DO, T-P, T-N, COD) suggested by Water Environment Standards, Ministry of Environment, Republic of Korea. We compared the water quality of one control (A: general ecological pond composition method of the laminated structure) and two experimental groups (B: a combination of aquatic plants and a water treatment media block, C: a water treatment media block only). As a result, we confirmed that the water treatment media block is an efficient and economical method to maintaining the water quality of the ecological pond for a long time. The water treatment media block will be a great help in providing a better aquatic biotope space for aquatic insects and fishes living in clear water.