• Title/Summary/Keyword: the w-operation

Search Result 2,473, Processing Time 0.032 seconds

A Study on the Characteristics of PCS Using a Solar Cells Generation of Optimal Integrated (최적 일체형 태양광 발전용 전력변환장치 PCS 특성에 관한 연구)

  • Hwang, Lark Hoon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1003-1014
    • /
    • 2019
  • In this paper, we modeled the devices used easily in PV system circuits. Simulation tools use PSPICE to enable intuitive electrical circuit simulations. Simulations were also performed on the effects of temperature and spatial radiation that are easy to overlook when using solar cells using modelled libraries. In addition, for full operation of the photovoltaic system, a complete operation system for the DC-DC buck-boost converter and the MPPT(Maximum Power Point Tracking) control system was modeled and simulated to confirm good operation. In order to verify the operation of the simulation, we constructed an actual system with the same conditions in the simulation and experimented. As a result, we proposed a single-phase 3 kW grid-connected solar power converter.

Dual Mode OLED for mobile application

  • Redecker, M.;Fischer, J.;Kim, S.W.;Chung, H.K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.805-807
    • /
    • 2004
  • Dual Mode technology has been developed as a new technology that allows to use a self-emissive display under full sunlight conditions. The new technology connects a LCD-like remissive operation mode in sunlight to an OLED-like self-emissive operation in the dark In the recent years, the focus of development has shifted towards the possibility of full colour operation.

  • PDF

5-Level Inverter for Excitation Voltage Control of SRM (SRM의 여자전압제어를 위한 5-레벨 인버터)

  • Lee, S.H.;Park, S.J.;Ahn, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.294-296
    • /
    • 2000
  • Energy recovery in the regenerative region is very important when SRM(Switched Reluctance Motor) is used in traction drive. This is because that to reduce energy loss during mechanical braking and/or to have a high efficiency drive during braking. To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation in SRM.

  • PDF

The Study on the Algorithm of Multi-Train Operation Simulation (다중 열차 운용시뮬레이션 알고리즘에 관한 연구)

  • Choi, K.H.;Gu, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.477-479
    • /
    • 1999
  • This paper proposed train operation simulation algorithm, algorithm to determining operational mode and algorithm for train performance program, which play a important role in multi-train operation simulation. Using railway network modelling and signalling systems modelling already developed, these algorithms was presented.

  • PDF

Analysis of the power requirements of a 55 kW class agricultural tractor during a garlic harvesting operation

  • Seung-Min, Baek;Wan-Soo, Kim;Seung-Yun, Baek;Hyeon-Ho, Jeon;Jun-Ho, Lee;Ye-In, Song;Yong, Choi;Young-Keun, Kim;Sang-Hee, Lee;Yong-Joo, Kim
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.1039-1050
    • /
    • 2021
  • The purpose of this study is to measure load data for a 55 kW class agricultural tractor during a harvesting operation and to analyze the required power according to the working conditions. A field test was conducted at three different tractor speeds (1.2, 1.3, and 1.4 km·h-1). A load measurement system was developed for the front axles, rear axles, and for power take-off (PTO). The torque and rotational speeds of the axles and PTO were measured during the field test and were calculated as the required power. The results showed that the total required power was in the range of 4.86 - 5.48 kW during the harvesting operation according to the tractor speed, and it was confirmed that this represents a ratio of 8.8 - 10.0% of the engine rated power. Also, it was confirmed that the required power of the axle and PTO increased as the tractor speed increased. In future studies, we plan to supplement the measurement system for a tractor to include a hydraulic system and perform a field test for harvesting various underground crops.

Numerical Simulation for the Subsurface Temperature Distribution Disturbed by Heat-Pump Operation (지열펌프 구동에 의한 지중 온도 분포 변화 모델링 연구)

  • Shin, Ji-Youn;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.40-43
    • /
    • 2006
  • Public demand for the heat pump system as a next generation energy equipment is increasing for its eco-friendly and cost-effective advantage. Many researches have been concentrated on how to calculate and develop its own efficiency, while the possible effect of the heat pump operation on the whole subsurface temperature distribution is relatively less considered, During the current study, subsurface temperature disturbance caused by seasonal surface temperature cycle in Busan area and general W-tube heat pump operation is simulated in 3-dimensional heterogeneous medium. It shows that subsurface deeper than 10m from the surface remains nearly unchanged throughout the 4 seasons and groundwater convect ion in highly permeable layer near the surface acts like a main path of heat plume from heat pump system, This implies the significance of detail descript ion in shallow sedimentary layer or highly permeable layer which plays an important role on the regional flow advection and heat transfer. Also, the effect of groundwater convection increases when the arrangement of the 2 injection pipes and 2 extract ion well is maintained parallel to groundwater flow. Therefore, more careful and detail investigation is required before installation and operation of heat pump system that it may not cause any possible change of microbial ecosystem in the shallow subsurface environment or 'contamination of temperature' for groundwater use as well as the loss of efficiency of the equipment itself. This can also help to design the optimized grouting system for heat pump.

  • PDF

A NEW CHARACTERIZATION OF PRÜFER v-MULTIPLICATION DOMAINS

  • CHANG, GYU WHAN
    • Korean Journal of Mathematics
    • /
    • v.23 no.4
    • /
    • pp.631-636
    • /
    • 2015
  • Let D be an integral domain and w be the so-called w-operation on D. In this note, we introduce the notion of *(w)-domains: D is a *(w)-domain if $(({\cap}(x_i))({\cap}(y_j)))_w={\cap}(x_iy_j)$ for all nonzero elements $x_1,{\ldots},x_m$; $y_1,{\ldots},y_n$ of D. We then show that D is a $Pr{\ddot{u}}fer$ v-multiplication domain if and only if D is a *(w)-domain and $A^{-1}$ is of finite type for all nonzero finitely generated fractional ideals A of D.

A study on performance comparison of jacket cooling fresh water system for marine diesel engine (선박용 디젤기관의 재킷 냉각청수시스템 성능 비교에 관한 연구)

  • Kim, Duk-Kyung;Lee, Jae-Hyun;Cho, Kwon-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.8-14
    • /
    • 2017
  • Due to the financial crisis in 2008, the world economy collapsed leading to an increase in oil prices and a decrease in freight by shipping. To overcome this crisis, major shipping companies ordered larger ships, changed their trading route and improved operating of ships to overcome deficits. In particular, low-speed navigation was much favored by many companies so that it can reduce fuel consumption. However, the long-term operation of high-speed optimized engines in low-speeds has affected the jacket cooling fresh water (J.C.F.W.) system as they fail to maintain the normal operational temperature. The temperature of J.C.F.W. system dropped leading to low temperature corrosion. As a result, when the engine is operating at minimal load the functioning of existing J.C.F.W cooler is decreased and the use of fresh water generator is substantially limited. Therefore, an improvement in the functioning of J.C.F.W. system is necessary. In this paper, in order to review the improvements required for the operation of J.C.F.W. of low-speed operating marine diesel, an experiment was conducted by comparing and analyzing the results of the main engine J.C.F.W. system of a Panamax class bulk carrier 82k and a Cape class bulk carrier 180k by installing and uninstalling the J.C.F.W. Cooler. Thus, this paper proposed an improved design of the J.C.F.W. system that is suitable for the present low-speed operation.

Study on Optimization of Operation in household Fuel Cell System (가정용 연료전지 시스템의 요금 분석을 통한 최적 운전 방법 검토)

  • Park, Deaheum;Cha, Kwangseok;Jo, Hokyoo;Jung, Younguan
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.6
    • /
    • pp.598-603
    • /
    • 2012
  • Despite the high efficiency and eco-friendly of Household Fuel Cell System it has hardly obtained popularity mainly due to its high prices. In order to encourage use of the system prices and operational expenses need to become economical. In this study, optimization through simulation was conducted to find out the optimal operational condition. As a result of simulation the system is operated with DSS operation from 5 O'clock to 19 O'clock for 14 hours at the constant output of 0.4kW to maximize reduction of energy rate. this DSS operation condition can reduce 200,000 won of energy rates in 35 pyoung apartment for a year. And, we can know that starting time of DSS operation don't effect to energy rates through the simulation. Furthermore, the household fuel cell system with the rated output of 1kW should be reduced to 0.4 - 0.6kW which can promote installation of household Fuel Cell System. Now, the household fuel cell system don't have been used widely due to economical efficiency. but, in the near future, Fuel Cell will be used to household by decrease of LNG price caused by development of shale gas.