• Title/Summary/Keyword: the standard of reference

Search Result 2,159, Processing Time 0.245 seconds

Methodology of Selecting Criteria for Pedestrian only Street (차없는 거리 선정기준 수립을 위한 방법론 정립 연구)

  • Kim, Yoomi;Park, Jejin;Lee, Junyoung;Ha, Taejun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.867-879
    • /
    • 2016
  • Since the 1970s, the region of its own pedestrian center and environmental pollution caused by exhaust gases have been reduced gradually in a continuous increase of the vehicle, school route the central business district, around the school, the sidewalk where the vehicle do not pass, facilities of minimum for the safety of pedestrians and systematic management of an area where an unspecified number and alleys impassable is insufficient. Recently, in response to the "Law for convenience enhancing safety and walking" is enforced in Korea, research on Pedestrian only Street has been actively about the government, the standard for calculating the weights of evaluation associated with it. it is a actuality, however, there are insufficient, evaluation for business promotion is being conducted evaluation polite manner by using, for example, scale residence time and purpose of the passengers as there is no car that has been carried out on a voluntary basis through the municipality have. In this study, by suggesting a method for the selection of the street without a car, make a survey by placing a purpose in the selection method presentation of the street with no car to be construction future, was researching. F.G.I (Focus Group Interview) survey, professors, staff in urban, traffic field of experts in order to present the weights for the evaluation of the Pedestrian only Street by using the evaluation index by type of Pedestrian only Street, was interviewed about the evaluation index for the conducted for professionals engaged in the engineering company, and randomly selected 200 peoples, weighted evaluation of the street with Pedestrian only Street was proposed. By classifying the items purpose and goals of the evaluation type by this by applying the weight, and present the weight of the detailed indicators each corresponding to each item, and scored on the basis of the result, in this paper it can be so that one methodology for the selection standard for the construction as Pedestrian only Street, and the weight of the evaluation of the type that has been derived, the selection and evaluation methods and then added to these criteria to settle careful study of the reference should be performed further.

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

Assessment and Prediction of Stand Yield in Cryptomeria japonica Stands (삼나무 임분수확량 평가 및 예측)

  • Son, Yeong Mo;Kang, Jin Taek;Hwang, Jeong Sun;Park, Hyun;Lee, Kang Su
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.3
    • /
    • pp.421-426
    • /
    • 2015
  • The objective of this paper is to look into the growth of Cryptomeria japonica stand in South Korea along with the evaluation on their yields, followed by their carbon stocks and removals. A total of 106 sample plots were selected from Jeonnam, Gyeongnam, and Jeju, where the groups of standard are grown. We only used 92 plots data except outlier. As part of the analysis, the Weibull diameter distribution was applied. In order to estimate the diameter distribution, the growth estimation equation for each of the growth factors including the height, the diameter at breast height, and the basal area was drafted out and the verification for each equation was examined. The site index for figuring out the forest productivity of Cryptomeria japonica stand for each district was also developed as a Schumacher model and 30yr was used as a reference age for the estimation of the site index. It was found that the site index for Cryptomeria japonica stand in South Korea ranges from 10 to 16 and this result was used as a standard for developing the stand yield table. According to the site 14 in the stand yield table, the mean annual increment (MAI) of the Cryptomeria japonica reaches $7.6m^3/ha$ on its 25yr and its growing stock is estimated to be at $190.1m^3/ha$. This volume is about $20m^3$ as high as that of the Chamaesyparis obtusa. Furthermore, the annual carbon absorptions for a Cryptomeria japonica stand reached the peak at 25yr, which is 2.14 tC/ha/yr, $7.83tCO_2/ha/yr$. When compared to the other conifers, this rate is slightly higher than that of a Chamaecyparis obtusa ($7.5tCO_2/ha/yr$) but lower than that of the Pinus koraiensis ($10.4tCO_2/ha/yr$) and Larix kaempferi ($11.2tCO_2/ha/yr$). With such research result as a base, it is necessary to come up with the ways to enhance the utilization of Cryptomeria japonica as timbers, besides making use of their growth data.

Analysis of Hematologic Characteristics of Korean Native Stripped Cattle Chickso according to the Ages (성장 단계별 희소 한우(칡소)의 혈액학적 분석)

  • Kim, Hyun;Cho, Young Moo;Ko, Yeoung-Gyu;Kim, Nam-Tae;Kim, Sung Woo;Seong, Hwan-Hoo
    • Journal of Embryo Transfer
    • /
    • v.29 no.3
    • /
    • pp.313-319
    • /
    • 2014
  • Investigations for hematologic values and the differential count of WBC for Korean indigenous cattle (KIC) and Stripped Cattle (SC) are rarely performed. Therefore, when the index of complete blood counts (CBC) analysis of KIC and SC were requested, it had many difficulties to make the results for blood condition since the standard hematologic values of KIC and SC are lacking. The objective of this study was to investigated the hematologic values and the differential count of WBC for blood of total 19 striped cattle (SC) and 187 KIC as a control by estimation analysis of hematologic characteristics. As a result, the mean values of RBC and platelet of KIC were significantly decreased by age (P<0.05). The mean values of RBC, HCT, MCV and MCHC between KIC and SC of the same age (2~3 years) showed the statistical significance (P<0.05). Also, in the WBC of KIC, the mean values were decreased according to the age from $13.8{\times}10^3/{\mu}l$ under 1 year to $9.5{\times}10^3/{\mu}l$ over 5 years. In the differential count of WBC of KIC, it showed generally the rates of 46.2% lymphocyte and 36% segmented neutrophil. Additionally, in comparative analysis between pregnant and non-pregnant group of KIC, the mean values of Hg and HCT in pregnant group were significantly decreased(P<0.05). In conclusion, data obtained from this study may be valuable as a standard for interpretation of the results in hematologic analysis of KIC. Result of this study will be used for establishing reference range for hematologic analysis in SC.

A Study on the Classification System of Cadastral Cultural Heritage : Focusing on LX museum collection (지적 문화유산 분류체계 연구 - LX국토정보박물관 소장품을 중심으로 -)

  • Kim, Ji-Hyun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.54 no.1
    • /
    • pp.63-74
    • /
    • 2024
  • The fundamental basis for revitalizing cultural resources and developing content is national heritage(cultural property). In national heritage, cultural heritage is a tangible cultural heritage that represents the uniqueness of history and tradition, identity, and changes in life. In the case of museums, the collections (a museum-owned cultural heritage) represent the unique characteristics of the institution. In South Korea, it is recommended that museum collections be registered and used in the Cultural Heritage Standard Management System so that cultural heritage can be managed and utilized in connection with academics, industry, and administration. However, due to a lack of awareness of modern and contemporary heritage, the thematic classification chronology of the system was set mainly before the Joseon Dynasty, and a cultural heritage classification system suitable for national land information has not been established. Therefore, this study aims to propose a classification system for cadastral cultural heritage, based on the modern era when cadastral terminology was first used, using the cultural heritage owned by the LX Museum. Cadastral cultural heritage is characterized by the fact that although it is a field of specialized technology, the surveying or the production of it is not done by specific individuals only, and that while the production is professional, there are many educational aspects in its use. Therefore, unlike other specialized museum collections that are classified based on the functional aspects of their production methods, intended use, and creators, the classification method for cadastral cultural artifacts should be based on the characteristics of the cadastral tools and the outputs. This classification follows a three-tier stages with reference to the items in the Cultural Heritage Standard Management System. This classification aims at the effective use of knowledge by categorizing concepts and systematizing the subjects of data into a series of orders. A safe conservation and management environment for cadastral cultural heritage can be established, and academic and socio-cultural interpretation of the collection is possible by this classfication. Moreover, It is also expected to serve the basis for the national land information as well as searching for the national land information research, planning a exhibition, and the field of education in museum.

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

Catalytic Spectrophotometry for the Determination of Manganese at Trace Levels by a Novel Indicator Reaction (새로운 지시약 반응에 의해 극미량 수준의 망간 측정을 위한 촉매 반응의 분광 광도 측정법)

  • Gurkan, Ramazan;Caylak, Osman
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.556-566
    • /
    • 2010
  • A new kinetic spectrophotometric method is developed for the measurement of Mn(II) in natural water samples. The method is based on the catalytic effect of Mn(II) with the oxidation of Gallocyanin by $KIO_4$ using nitrilotriacetic acid (NTA) as an activation reagent at 620 nm. The optimum conditions obtained are $4.00{\times}1^{-5}\;M$ Gallocyanin, $KIO_4$, $1.00{\times}10^{-4}\;M$ NTA, 0.1 M HAc/NaAc buffer of pH = 3.50, the reaction time of 5 min and the temperature of $30^{\circ}C$. Under the optimum conditions, the proposed method allows the measurement of Mn(II) in a range of $0.1\;-\;4.0\;ng\;mL^{-1}$ and with a detection limit of down to $0.025\;ng\;mL^{-1}$. The recovery efficiency in measuring the standard Mn(II) solution is in a range of 98.5 - 102%, and the RSD is in a range of 0.76 - 1.25%. The newly developed kinetic method has been successfully applied to the measurement of Mn(II) in both some environmental water samples and certified standard reference river water sample, JAC-0031 with satisfying results. Moreover, few cations and anions interfere with the measurement of Mn(II). Compared with the other catalytic-kinetic methods and instrumental methods, the proposed kinetic method shows fairly good selectivity and sensitivity, low cost, cheapness, low detection limit and rapidity. It can easily and successfully be applied to the real water samples with relatively low salt content and complex matrices such as bottled drinking water, cold and hot spring waters, lake water, river water samples.

Distribution Characteristics of the Concentration of Ambient PM-10 and PM-2.5 in Daegu Area (대구지역 대기 중 PM-10과 PM-2.5의 농도분포 특성)

  • Do, Hwa-Seok;Choi, Su-Jin;Park, Min-Sook;Lim, Jong-Ki;Kwon, Jong-Dae;Kim, Eun-Kyung;Song, Hee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.20-28
    • /
    • 2014
  • The three air quality monitoring sites, analysed simultaneously PM-10 and PM-2.5, ie. Ihyeondong in industrial area, Manchondong in residential area, Pyeongnidong in streetside, among 13 air quality monitoring sites in Daegu area, were investigated the concentration distribution characteristics of PM-2.5 and PM-10 in the last 2 years (2011~2012). PM-10 concentrations exceeded annual average reference value ($50{\mu}g/m^3$) in Ihyeondong ($52.5{\mu}g/m^3$) and Pyeongnidong ($60.9{\mu}g/m^3$) but satisfied in Manchondong ($44.9{\mu}g/m^3$). All PM-2.5 concentrations exceeded EPA annual standard value of the United States ($15{\mu}g/m^3$) in three points, but also exceeded new control annual standard value ($25{\mu}g/m^3$) coming into effect in 2015. Seasonal concentration of PM-10 appeared the order of spring > winter > fall > summer, and in the case of PM-2.5, the order was winter > spring > fall > summer. Monthly concentrations of PM-10 and PM-2.5 were highest in February and lowest in September. Diurnal concentrations of PM-10 and PM-2.5 increased from 7:00 AM, and recorded the highest concentration between 10:00 AM and 11:00 AM. And after 6:00 PM it lowered continuously and tended to show fixed concentrations from evening until early morning. In addition, the concentration of fine particles during the week was higher than the weekend. The fluctuation in industrial area was larger than the residential area. At the PM-2.5/PM-10 ratio, summer was generally high, spring was the lowest. And, when yellow sand occurred, it was 0.32 to 0.42. It was very low compared to 0.54 to 0.64 during non-yellow sand times. This paper for the state and the characteristics of Daegu' fine particles (PM-10, PM-2.5) will be valuable to future researches of fine particles and air pollution management.

A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry (치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구)

  • Park, Ilwoo;Jeung, Wonkyo;Hwang, Hyungsuk;Lim, Sunghwan;Lee, Daenam;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2013
  • This study estimate radiation biological danger factor by measuring patient's exposed dose and propose the low way of patient's exposed dose in panoramic radiography. We seek correcting constant of OSL dosimeter for minimize the error of exposed dose's measurement and measure the Left, Right crystalline lens, thyroid, directly included upper, lower lips, the maxillary bone and the center of photographing that indirect included in panoramic radiography by using the human body model standard phantom advised in ICRP. In result, the center of photographing's level of radiation maximum value is $413.67{\pm}6.53{\mu}Gy$ and each upper, lower lips is $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$. Also in panoramic radiography, indirect included Left, Right crystalline lens's level of radiation are $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$, and thyroid's level of measured exposed dose can cause effect of radiation biological and we need justifiable analysis about radiation defense rule and substantiation advised international organization for the low way of patient's exposed dose in panoramic radiography of dental clinic and we judge need the additional study about radiation defense organization for protect the systematize protocol's finance and around internal organs for minimize until accepted by many people that is technological, economical and social fact by using panoramic measurement.