• 제목/요약/키워드: the standard of reference

검색결과 2,150건 처리시간 0.031초

건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구 (A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings)

  • 정영선;정해권;장희경;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

Design of a Fast Multi-Reference Frame Integer Motion Estimator for H.264/AVC

  • Byun, Juwon;Kim, Jaeseok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권5호
    • /
    • pp.430-442
    • /
    • 2013
  • This paper presents a fast multi-reference frame integer motion estimator for H.264/AVC. The proposed system uses the previously proposed fast multi-reference frame algorithm. The previously proposed algorithm executes a full search area motion estimation in reference frames 0 and 1. After that, the search areas of motion estimation in reference frames 2, 3 and 4 are minimized by a linear relationship between the motion vector and the distances from the current frame to the reference frames. For hardware implementation, the modified algorithm optimizes the search area, reduces the overlapping search area and modifies a division equation. Because the search area is reduced, the amount of computation is reduced by 58.7%. In experimental results, the modified algorithm shows an increase of bit-rate in 0.36% when compared with the five reference frame standard. The pipeline structure and the memory controller are also adopted for real-time video encoding. The proposed system is implemented using 0.13 um CMOS technology, and the gate count is 1089K with 6.50 KB of internal SRAM. It can encode a Full HD video ($1920{\times}1080P@30Hz$) in real-time at a 135 MHz clock speed with 5 reference frames.

ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로 (Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784)

  • 이상현;손승녀;김남선;조용성
    • 한국ITS학회 논문지
    • /
    • 제12권3호
    • /
    • pp.29-41
    • /
    • 2013
  • 본 연구는 교통정보센터와 노변장치간 국제표준 규격인 ISO 15784를 적용하여 국내 환경에 맞는 노변장치와 교통정보센터간 정보교환 표준 개발을 목표로 한다. 이를 위해 ISO 14817과 ISO 14827 Part 1을 참조하여 메시지 교환 시나리오 개념의 메시지 기본 개념과 시스템 구축 호환성 확보를 위해 명확히 정의가 필요한 필수 메시지 정의 항목을 정의하였다. AVI와 교통정보센터간 교환되는 실제 메시지 표준 개발을 위해 ITS 표준 기술위원회에 표준실무팀을 구성하여, ITS 아키텍쳐 정보흐름 분석, 국내 기 표준 분석, 현재 시내부와 국도상에 실제 설치되어 운영되고 있는 AVI 장비 메시지 프로토콜을 비교분석하여 총 14개의 기능 메시지를 정의하고, 이에 대해 DATEX 응용 프로토콜의 메시지 교환 시나리오에 따라 총 28개 메시지를 정의하였다. 데이터 교환을 위한 응용프로토콜은 ISO 15784의 참조표준을 분석하여 국내 현장장비와 교통정보센터간 데이터교환 환경을 고려한 상호운영성 및 상호호환성 확보를 위한 요구사항을 정의하였다.

Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

  • Dong Wook Kim;Jiyeon Ha;Yousun Ko;Kyung Won Kim;Taeyong Park;Jeongjin Lee;Myung-Won You;Kwon-Ha Yoon;Ji Yong Park;Young Jin Kee;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.624-633
    • /
    • 2021
  • Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

토양오염 우려기준과 토양 자연배경농도에 대한 위해성평가 (Risk assessment for Soil Contamination Warning Standard and Soil Background Concentration)

  • 신동;박성재;조영태;봉재은;박정훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권3호
    • /
    • pp.37-49
    • /
    • 2021
  • There is domestic Soil Contamination Warning Standard (SCWS) as remediation standard concentration of contaminated soils. No risk should be observed at soil concentration less than SCWS. Therefore, SCWS was evaluated to confirm the risk assessment. Background Concentration of Soil (BGC) and target remediation concentration were also assessed. The results show that Excess Cancer Risk (ECR) of SCWS was the highest in the groundwater intake pathway (Adult: 6.27E-04, Child: 2.81E-04). Total Cancer Risk (TCR) was 7.76E-04 and 4.30E-04 for adult and child, exceeding reference value (10-6). Hazard Quotient (Non-Carcinogenic Risk, HQ) was the highest in the indoor air inhalation pathway (Adult: 3.64E+03, Child: 8.74E+02). Hazard Index (Total Non-Carcinogenic Risk, HI) exceeded reference value 1. ECR of the BGC was the highest in the groundwater intake pathway (Adult: 1.71E-04, Child: 7.67E-05). TCR was 2.12E-04 for adults and 1.17E-04 for children, exceeding the reference value (10-6). HQ was the highest in groundwater intake pathway (Adult: 4.10E-01, Child: 1.84E-01). HI was lower than reference value 1 (Adult: 4.78E-01, Child: 2.50E-01). The heavy metal affecting ECR was Arsenic (As). The remediation-concentration of As was 7.14 mg/kg which is higher than BGC (6.83 mg/kg). TCR of As should be less than reference value (10-6), but it was higher for all of SCWS, BGC and target remediation concentration. Therefore, it is suggested that risk assessment factors should be re-evaluated to fit domestic environmental settings and SCWS should be induced to satisfy the risk assessment.

급수기구 발생음의 실험실 측정방법 제1부 : 측정방법 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement)

  • 양관섭;정갑철;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.845-850
    • /
    • 2003
  • Noise caused by water installations may lead to annoyance in adjacent rooms, for example in dwellings. hospitals and hotels. This part of standard describes a method of measurement allowing comparable results to be obtained in laboratory measurements. The test conditions described herein constitute the standard reference conditions essential for comparisons between laboratories.

  • PDF

전파환경에 의한 DGPS 충주 기준국의 성능저하 분석 (Analysis on the Performance Degradations of Chung-Ju DGPS Reference Station by Radio Environment)

  • 박슬기;한영훈;박상현;최용권;이상정
    • 한국정보통신학회논문지
    • /
    • 제20권9호
    • /
    • pp.1822-1829
    • /
    • 2016
  • GPS 항법의 정확도 향상과 무결성 정보의 필요성으로, 국내에 DGPS를 구축하였다. 최근에는 측위정보를 해양에서 뿐만 아니라 육상에서도 활용할 수 있도록 제공하고 있다. 그러나 2015년도 충주 기준국의 성능저하 문제점을 파악하기 위하여 영도기준국과 함께 가시성과 전파환경을 조사하였다. 영도기준국의 경우, 가시성과 전파환경이 기준국 기준에 만족하였다. 그러나 충주기준국의 경우, 가시성은 막음각 7도 이하로 장애물이 존재하여 만족하지만 전파환경에서 신호잡음은 최대 -50dBm으로 기준치인 -70dBm을 넘어가는 것을 확인하였다. 이러한 전파환경으로 인한 측정치오차를 분석하기 위하여 신호잡음등의 오차를 포함하지 않는 시차분 측정치 분석방법을 제안하였다. 2015년 12월 측정치 분석결과 충주 기준국의 경우 영도 기준국 보다 3배의 오차를 확인하였다. 이 뿐만 아니라 기준국 장비문제로 인한 측정치 성능저하를 확인하였다. 추후에는 17개소의 기준국의 측정치를 분석하여 성능검증을 진행할 예정이다.

Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 - (A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials -)

  • 이민효;이군택;주창규;김용훈;이법열;최성헌;김명옥;홍석영;김금희;이원석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.

진단검사의학 검체검사의 정상치와 참고치

  • 이갑노
    • 한국건강관리협회지
    • /
    • 제1권1호
    • /
    • pp.19-20
    • /
    • 2003
  • In Korea association of health promotion(KHAP) there are fourteen laboratories in branch offices and one laboratory in headquarter office. To standardize the reference ranges of all laboratories of KAHP, they have been newly calculated from the laboratory data perfomed during the previous yearsby statistical metod annually for the period of 2000 through2003 so far. The referance ranges of total 56 test items were assigned. Among these there were eight test items that needed referance ranges by age groups and nine test items that needed reference rages by gender. The age grouping was into six groups : baby (0-3y), children(4-12y), adolescent(13-18y), adult(19-64y), younger elderly(19-64y), older elderly(over 80y) with references of statics in Medical Informatics and WHO classification. All the data collected were statistically analyzed with SAS 6.04 for Gaussian distribution that had been repeated two or three times after trimming out the the tests showed Gaussian distribution. Subsequently, Thereference ranges were defined in the rage from the point of lower 2.5% to the point of higher 97.5%. And in case the lower range could be "0", the reference ranges were defined in the range of 0 to 95%. Fifteen laboratoried troughout Korea of KAHP currently have standarzed reference rages of the tests that they perform. This means the patient data and reference values an be exchangeable among laboratories of KHAP.Annual revise of such reference rages can eventually lead to the level of those representing a standard of the national reference ranges.

  • PDF