• Title/Summary/Keyword: the standard of reference

Search Result 2,150, Processing Time 0.035 seconds

Reference Symbol Arrangement in LTE OFDM Systems (LTE OFDM 시스템에서의 기준 심볼 배치)

  • Choi, Seung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2805-2812
    • /
    • 2015
  • For the purpose of estimation of time variant frequency selective transmission channels, reference symbols are usually employed. The bit error performance of LTE OFDM systems is analyzed in the case of LTE standard reference symbol arrangement. Results show that LTE OFDM system with this LTE reference symbol arrangement is robust against Doppler time variant fading. However, the performance of that system is degraded due to channel estimation error in frequency domain. An equidistant arrangement with a diamond shape structure of reference symbols, however having 4 subcarriers distance in frequency domain, is suggested for the optimal channel estimation.

A Self-Biased Current Reference in $0.25{\mu}m$ CMOS Technology

  • Park, Jae-Woo;Yoo, Chang-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.635-636
    • /
    • 2006
  • A self-biased CMOS current reference is described which provides supply and temperature independent bias current. The supply independency is obtained by subtracting two bias currents which have the same supply dependency. Unlike the conventional self-bias CMOS current reference, excellent supply independency can be obtained even with the minimum channel length devices and thus smaller area implementation becomes possible. The supply independent bias current is then applied to a temperature compensating circuit and as a result supply and temperature independent bias current is obtained. The current reference has been implemented in a $0.25{\mu}m$ standard CMOS technology. The active silicon area is only $45{\mu}m{\times}45{\mu}m$. The simulated temperature coefficient is 64ppm/$^{\circ}C$ in temperature range between $0^{\circ}C$ and $120^{\circ}C$. Supply voltage can be as low as 1.3V and the supply dependency of the current reference is measured to be smaller than 4500ppm/V. While providing $10.25{\mu}A$ output current, the current reference consumes $160{\mu}W$.

  • PDF

An Evaluation of Reference Values Used for Quality Control of the Korean Industrial Hygiene Laboratory (우리나라 작업환경 측정기관의 정도관리를 위한 기준값에 관한 연구)

  • Cheon, Cheong Hwa;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.103-116
    • /
    • 1994
  • This study was conducted to evaluate accuracy and precision of reference values used for quality control of the Korean industrial hygiene laboratory for three rounds. Factors affecting on accuracy and precision, including analytical procedures, were investigated. The results are summarized as follows. 1. Pooled relative standard deviation of reference values analyzed by reference laboratories was 2.01-5.91%, and that by both reference laboratories and participated laboratories was 3.18-6.63%. Better results were obtained when results of reference laboratories were employed. 2. Significant relationship was indicated between analytical precision and concentration of materials in samples. Variation increased by decreasing sample concentration. 3. Recoveries of lead and cadmium were about 98.6% and 99.8% respectively. There was a significant difference between lead values with and without recovery correction. 4. Organic solvent results corrected by desorption efficiency only and those corrected by Both internal standards and desorption efficiency were more accurate than those uncorrected. But, the latter was the best.

  • PDF

Multielement Analysis in Airborne Particulate Matter $(PM_{10})$ by INAA, ICP and AAS (INAA.ICP.AAS를 이용한 대기먼지 $(PM_{10})$의 다원소분석)

  • 정용삼;문종화;정영주;박광원;이길용;윤윤열;심상권;조경행;한명섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.495-503
    • /
    • 1999
  • Airborne particulate matter $(PM_{10})$ collected using high volume air sampler and silica fiber filter were analyzed by Instrumental Neutron Activation Analysis(INAA), Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) and Atomic Absorption Spectrometry(AAS), and the results were compared with each other. 30~40 trace elements in environmental standard reference materials(NIST SRM 1648 and NIES CRM No.8) were analyzed for the analytical quality control. The relative error for two-third of elements detected was less than 10%, and the standard deviation was less than 15%. During the sampling period for 24 hours, the mass concentration of total suspended particulate was 36.1$\mu\textrm{g}$/㎥ and the value is lower than the critical level in Korea. In the results of NAA, the elements of Al, As, Ba, Fe, La, Mg, Na, Sb, Zn were well agreed with those of other methods. In statistical estimation between different methods, the deviation of Al, Ba, Cr, Fe was less than 10% and quite reliable.

  • PDF

Standard Reference Model Analysis for Smart Farming based on Networks (네트워크 기반에서의 스마트 농업 표준 기준모델 분석)

  • Kim, Dong Il;Chung, Hee Chang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2703-2709
    • /
    • 2015
  • IT convergence with agriculture is expected to bring more efficiency and quality improvement in producing, distributing, consuming of agricultural products with the aid of information processing and autonomous control technologies of the IT area. Smart Farming based on network is a service which is capable of coping with environmental and technical problems with the actualized IT convergence case for agriculture. In this paper, it is required to consider the actualized IT convergence case for agriculture, namely Smart Farming as a solution to cope the presented problems. In addition, propose and suggest to standard model and standardization items requirement for the Smart Farming based on network.

Quantitative Analysis of Chloride by Heteronuclear Electronic Reference NMR Method

  • Lee, Sueg-Geun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.11 no.2
    • /
    • pp.115-121
    • /
    • 2007
  • A new quantitative analysis of chloride by the HERETIC NMR method which does not need internal or external references was described. The results showed that the use of HERETIC peak corresponding $500\;{\mu}g/mL$ of chloride calibration showed less than 4 % standard deviations from 50 to $5000\;{\mu}g/mL$ range of chloride concentrations.

  • PDF

RRT Study for the Quantitative Analysis of Boron in Silicon (실리콘에 도핑된 붕소의 정량분석에 대한 공동분석연구)

  • 김경중;김현경;문대원;홍태은;정칠성;김이경;김재남;임철호;김정호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.4
    • /
    • pp.218-224
    • /
    • 2002
  • A domestic round robin test(RRT) for the quantitative analysis of minor impurities was performed by a standard procedure and standard reference material. The certified reference material(CRM)s for B-doped Si thin film and analysis specimens and the analysis specimens were prepared by an ion beam sputter deposition method. These samples were certified by inductively coupled plasma mass spectrometry(ICP-MS) with isotope dilution method which il one of the most quantitative methods in chemical analysis. By using an international standard procedure(ISO/DIS-l4237) for the quantitative analysis of B in Si by SIMS, a domestic RRT was performed for these specimens. Although only a few laboratories participated in this RRT, the average B concentration well agreed with the certified value within 2% error.

Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna (생태독성 숙련도 시료의 적절성 평가)

  • Shin, Kisik;Park, Woosang;Lee, Jungseo;Yu, Soonju;Park, Taejin;Kim, Jongmin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

A Study on the Reference Model for Integrated Urban Spatial Information Management Platform (지능형 도시공간정보 통합플랫폼 참조모델 개발 연구)

  • Hong, Sang-Ki;Cho, Sung-Youn
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.4
    • /
    • pp.19-27
    • /
    • 2009
  • Integrated Urban Spatial Information Management Platform (USIMP) is defined as an operational environment where technologies for intelligent management of urban facilities are made possible through the integration of diverse technologies such as sensors for ground and underground facilities, middleware technology, wired and wireless network, GIS-USN linkage. To make the integration of these diverse technology possible, it is imperative to have a sound reference model for the platform. This paper provides a standardized reference model for USIMP based on the RM-OPD(Reference Model for Open Distributed Processing) standard.

  • PDF