• Title/Summary/Keyword: the standard of reference

Search Result 2,150, Processing Time 0.028 seconds

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

Design of a Fast Multi-Reference Frame Integer Motion Estimator for H.264/AVC

  • Byun, Juwon;Kim, Jaeseok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.430-442
    • /
    • 2013
  • This paper presents a fast multi-reference frame integer motion estimator for H.264/AVC. The proposed system uses the previously proposed fast multi-reference frame algorithm. The previously proposed algorithm executes a full search area motion estimation in reference frames 0 and 1. After that, the search areas of motion estimation in reference frames 2, 3 and 4 are minimized by a linear relationship between the motion vector and the distances from the current frame to the reference frames. For hardware implementation, the modified algorithm optimizes the search area, reduces the overlapping search area and modifies a division equation. Because the search area is reduced, the amount of computation is reduced by 58.7%. In experimental results, the modified algorithm shows an increase of bit-rate in 0.36% when compared with the five reference frame standard. The pipeline structure and the memory controller are also adopted for real-time video encoding. The proposed system is implemented using 0.13 um CMOS technology, and the gate count is 1089K with 6.50 KB of internal SRAM. It can encode a Full HD video ($1920{\times}1080P@30Hz$) in real-time at a 135 MHz clock speed with 5 reference frames.

Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784 (ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로)

  • Lee, Sang-Hyun;Son, Seung-Neo;Kim, Nam-Sun;Cho, Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.29-41
    • /
    • 2013
  • This study set out to developing data exchange standard between roadside device and traffic information center fitted in a domestic environment by applying international standard ISO 15784. First, we defined message basic concept of 'Dialog' and essential elements should be defined to define the standard message for securing system compatibility by reference ISO 14817 and ISO 14827 Part 1. For defining standard message items exchanged between AVI and traffic information center, we formed Working Group under ITS Standards Technical Committee and analyzed data flow for ITS National Architecture, Standard messages of existing standards, and AVI operation messages actually operated on roadside now. So, we extracted 14 functionally needed messages and defined 28 standard messages adopting 'Dialog' concept. In case of the application protocol for data exchange standards, we defined basic requirements for securing interoperability and interchangeability considering domestic environment by analyzing reference standard of ISO 15784.

Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

  • Dong Wook Kim;Jiyeon Ha;Yousun Ko;Kyung Won Kim;Taeyong Park;Jeongjin Lee;Myung-Won You;Kwon-Ha Yoon;Ji Yong Park;Young Jin Kee;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.624-633
    • /
    • 2021
  • Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

Risk assessment for Soil Contamination Warning Standard and Soil Background Concentration (토양오염 우려기준과 토양 자연배경농도에 대한 위해성평가)

  • Shin, Dong;Park, Seong-Jae;Jo, Young Tae;Bong, Jae-eun;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.3
    • /
    • pp.37-49
    • /
    • 2021
  • There is domestic Soil Contamination Warning Standard (SCWS) as remediation standard concentration of contaminated soils. No risk should be observed at soil concentration less than SCWS. Therefore, SCWS was evaluated to confirm the risk assessment. Background Concentration of Soil (BGC) and target remediation concentration were also assessed. The results show that Excess Cancer Risk (ECR) of SCWS was the highest in the groundwater intake pathway (Adult: 6.27E-04, Child: 2.81E-04). Total Cancer Risk (TCR) was 7.76E-04 and 4.30E-04 for adult and child, exceeding reference value (10-6). Hazard Quotient (Non-Carcinogenic Risk, HQ) was the highest in the indoor air inhalation pathway (Adult: 3.64E+03, Child: 8.74E+02). Hazard Index (Total Non-Carcinogenic Risk, HI) exceeded reference value 1. ECR of the BGC was the highest in the groundwater intake pathway (Adult: 1.71E-04, Child: 7.67E-05). TCR was 2.12E-04 for adults and 1.17E-04 for children, exceeding the reference value (10-6). HQ was the highest in groundwater intake pathway (Adult: 4.10E-01, Child: 1.84E-01). HI was lower than reference value 1 (Adult: 4.78E-01, Child: 2.50E-01). The heavy metal affecting ECR was Arsenic (As). The remediation-concentration of As was 7.14 mg/kg which is higher than BGC (6.83 mg/kg). TCR of As should be less than reference value (10-6), but it was higher for all of SCWS, BGC and target remediation concentration. Therefore, it is suggested that risk assessment factors should be re-evaluated to fit domestic environmental settings and SCWS should be induced to satisfy the risk assessment.

Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement (급수기구 발생음의 실험실 측정방법 제1부 : 측정방법)

  • 양관섭;정갑철;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.845-850
    • /
    • 2003
  • Noise caused by water installations may lead to annoyance in adjacent rooms, for example in dwellings. hospitals and hotels. This part of standard describes a method of measurement allowing comparable results to be obtained in laboratory measurements. The test conditions described herein constitute the standard reference conditions essential for comparisons between laboratories.

  • PDF

Analysis on the Performance Degradations of Chung-Ju DGPS Reference Station by Radio Environment (전파환경에 의한 DGPS 충주 기준국의 성능저하 분석)

  • Park, SulGee;Han, YoungHoon;Park, SangHyun;Choi, YongKwon;Lee, Sang Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1822-1829
    • /
    • 2016
  • DGPS Reference station is established in Korea for improvement of GPS navigation accuracy and needs of integrity. Recently, DGPS stations provide user positioning information on land as well as ocean. However, this paper investigated visibility and interference environment for performance degradation of Chung-ju DGPS reference station. In case of Young-do reference station, visibility and interference environment were satisfied with reference standard. In case of Chung-ju reference station, visibility was satisfied with 7 degree elevation angle. However, interference environment was not satisfied with reference standard of -50dBm. This paper proposed time differential measurement analysis method excluding error of signal noise for analyzing measurement error. Chung-ju reference station measurement analysis result is three times the error than on Young-do in Dec, 2015. In addition, this paper has confirmed measurement performance degradations because of reference station equipment problem. Future study will be carried out performance analysis of 17 DGPS reference station.

A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials - (Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 -)

  • Lee, Minhyo;Lee, Guntaek;Joo, Changkyu;Kim, Yonghun;Lee, Bupyoel;Choe, Sunghun;Kim, Myeongock;Hong, Sukyoung;Kim, Gumhee;Lee, Wonseok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.

진단검사의학 검체검사의 정상치와 참고치

  • Lee, Gap-No
    • Journal of Korea Association of Health Promotion
    • /
    • v.1 no.1
    • /
    • pp.19-20
    • /
    • 2003
  • In Korea association of health promotion(KHAP) there are fourteen laboratories in branch offices and one laboratory in headquarter office. To standardize the reference ranges of all laboratories of KAHP, they have been newly calculated from the laboratory data perfomed during the previous yearsby statistical metod annually for the period of 2000 through2003 so far. The referance ranges of total 56 test items were assigned. Among these there were eight test items that needed referance ranges by age groups and nine test items that needed reference rages by gender. The age grouping was into six groups : baby (0-3y), children(4-12y), adolescent(13-18y), adult(19-64y), younger elderly(19-64y), older elderly(over 80y) with references of statics in Medical Informatics and WHO classification. All the data collected were statistically analyzed with SAS 6.04 for Gaussian distribution that had been repeated two or three times after trimming out the the tests showed Gaussian distribution. Subsequently, Thereference ranges were defined in the rage from the point of lower 2.5% to the point of higher 97.5%. And in case the lower range could be "0", the reference ranges were defined in the range of 0 to 95%. Fifteen laboratoried troughout Korea of KAHP currently have standarzed reference rages of the tests that they perform. This means the patient data and reference values an be exchangeable among laboratories of KHAP.Annual revise of such reference rages can eventually lead to the level of those representing a standard of the national reference ranges.

  • PDF