• Title/Summary/Keyword: the standard body measurement

Search Result 268, Processing Time 0.026 seconds

Molecular Identification and Morphological Description of Larvae of the Previously Unrecorded Species Cryptacanthodes bergi (Zoarcoidei: Cryptacanthodidae) collected from Gangwon Province, Korea (강원도에서 채집된 등가시치아목 1미기록종, Cryptacanthodes bergi 자어의 분자동정 및 형태기재)

  • Choi, Si-Won;Lee, Soo-Jeong;Kim, Jin-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.2
    • /
    • pp.188-193
    • /
    • 2021
  • On March 13, 2018 two postflexion larval specimens (18.28 mm and 16.80 mm in standard length) belonging to the family Cryptacanthodidae, suborder Zoarcoidei were collected from Sokcho and Gangneung in Gangwon Province. The family Cryptacanthodidae comprises 4 species worldwide: 3 in the North Pacific Ocean and 1 in the western North Atlantic Ocean. As a result of analyzing 620 bp of the mtDNA COI region, the two postflexion larvae collected in this study were identified as Cryptacanthodes bergi by 99.5% agreement with C. bergi adult registered in NCBI. Postflexion larvae of C. bergi are compressed with large eyes and radial pectoral fins and the anus located in front of the center of the body. Melanophores were intensively distributed along the dorsal midline, except for caudal peduncle, and sporadically distributed on the back of the anus. In addition, there were limited star-like melanophores on the back of the gut. This species showed 0.058 genetic distance when compared mtDNA COI region of C. aleutensis, and it was well distinguished in the distribution pattern of black vesicles of the head, count and measurement traits. Considering the morphological and ecological characteristics of this species, we suggest a new Korean name, " Gwisin-jang-gaeng-i ".

Validity of predictive equations for resting energy expenditure in Korean non-obese adults

  • Ndahimana, Didace;Choi, Yeon-Jung;Park, Jung-Hye;Ju, Mun-Jeong;Kim, Eun-Kyung
    • Nutrition Research and Practice
    • /
    • v.12 no.4
    • /
    • pp.283-290
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: Indirect calorimetry is the gold-standard method for the measurement of resting energy expenditure. However, this method is time consuming, expensive, and requires highly trained personnel. To overcome these limitations, various predictive equations have been developed. The objective of this study was to assess the validity of predictive equations for resting energy expenditure (REE) in Korean non-obese adults. SUBJECTS/METHODS: The present study involved 109 participants (54 men and 55 women) aged between 20 and 64 years. The REE was measured by indirect calorimetry. Nineteen REE equations were evaluated for validity, by comparing predicted and measured REE results. Predictive equation accuracy was assessed by determining percent bias, root mean squared prediction error (RMSE), and percentage of accurate predictions. RESULTS: The measured REE was significantly higher in men than in women (P < 0.001), but the difference was not significant after adjusting for body weight (P > 0.05). The equation developed in this study had an accuracy rate of 71%, a bias of 0%, and an RMSE of 155 kcal/day. Among published equations, the $FAO_{weight}$ equation gave the highest accuracy rate (70%), along with a bias of -4.4% and an RMSE of 184 kcal/day. CONCLUSIONS: The newly developed equation provided the best accuracy in predicting REE for Korean non-obese adults. Among the previously published equations, the $FAO_{weight}$ equation showed the highest overall accuracy. Regardless, at an individual level, the equations could lead to inaccuracies in a considerable number of subjects.

Ultrasonographic Evaluation of Renal Cortex and Outer Medulla Thickness in Dogs with Chronic Kidney Disease

  • Lee, Siheon;Hong, Sungkyun;Kim, Hyejin;Oh, Dayoung;Kim, Seungji;Choen, Sangkyung;Choi, Mincheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.34 no.3
    • /
    • pp.208-212
    • /
    • 2017
  • This study was performed to retrospectively pursue any correlation between renal cortex thickness (RCT), outer medulla thickness (OMT) on ultrasonography (US) and chronic kidney disease (CKD) with International Renal Interest Society (IRIS) stage. Medical records and US findings of the dogs diagnosed CKD were reviewed for comparing to those of the clinically healthy dogs from March. 2015 through June. 2016. To evaluate the correlation about normal and CKD patients, RCT and the OMT were measured on US images. RCT and OMT were adjusted by dividing body surface area for standardization (RCTS, OMTS). Also the ratio of RCT/OMT were calculated and these indices were evaluated to investigate any tendency between 5 groups (normal and 4 IRIS stages) using Jonckheere-Terpstra trend test (J-T test). The RCTS showed a declining tendency (p < 0.02) and the OMTS showed an inclining tendency from normal through each IRIS stage (p < 0.01). The RCT/OMT showed also declining tendency (p < 0.01). Although the gold standard for renal function including GFR is lack, it is thought that differentiation between normal and CKD patients could be possible on US measurement of renal cortex and outer medulla thickness, which could be an alternative index for kidney function in diagnostic imaging.

Relationship between Quantitative Sonographic Measurements and Serum Biochemical Parameters in Childhood Obesity

  • Damar, Cagri;ISik, Emregul;Gungor, Sukru
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.5
    • /
    • pp.470-482
    • /
    • 2021
  • Purpose: We investigated the relationship between sonographic measurements of fatty liver and body mass index standard deviation score (BMI-Z score), abdominal wall fat thickness (AWFT), and serum biochemical parameters in childhood obesity. Methods: Anthropometric, laboratory, and ultrasonography data were obtained from 174 children with BMI-Z score >1. After the qualitative grading of hepatosteatosis (grades 0-3), the quantitative liver-kidney echogenicity ratio (LKER) was calculated using a software tool. Groups according to sex, age (AG-I to AG-III), BMI-Z score (BMG-I to BMG-III), and hepatosteatosis degree (HS-I and HS-II) were formed. The differences and distributions of the variables were statistically analyzed and compared among the groups. Results: Serum transaminase and glucose levels showed a positive correlation with LKER, whereas the HDL level showed a negative correlation. BMI-Z score and AWFT showed a positive correlation with fasting insulin level and HOMA-IR value. LKER was significantly higher in girls than in boys (p=0.008). In the AG-I group (age 3-8.9 years), the BMI-Z score was significantly higher, whereas AWFT was significantly lower than in the other age groups (p<0.001). The cutoff point of LKER for predicting grade 2 or higher steatosis (HS-II group) was determined to be 1.83. Cardiovascular disease risk was significantly higher in the HS-II group (p=0.035). Conclusion: As a valuable quantitative measurement tool, LKER can be used for the sonographic screening of fatty liver. AWFT, on the basis of its correlation with fasting insulin level and HOMA-IR value, may be a useful sonographic parameter in the management of childhood obesity.

Development of Sports Brassiere Pattern Using 3D Shaping Technology (3차원 쉐이핑 기술을 활용한 스포츠 브래지어 개발)

  • Kim, Soyoung
    • Fashion & Textile Research Journal
    • /
    • v.21 no.4
    • /
    • pp.480-487
    • /
    • 2019
  • This study used 3D technology to develop a multi-functional sports brassiere with increased comfort and fit that can be worn as a base layer during exercise or as underwear. A 75A size industrial lingerie figure was used to develop a standard pattern. 3D tools for scanning and pattern making, such as Vivid 910, Geomagic Design X, 2C-AN and Yuka CAD were used. The sports brassiere was designed as a tank top style with dual structure and linings attached to a pad utilized with a sport brassiere mold cup. 3D outer and lining's pattern was differently developed in consideration of the body's curvature with pad's shape and structure. Shoulder and neck part reduction rates were adjusted to increase the neck areas fit that considered the nude pattern's structure due to uncomfortableness felt by wearers who were uncomfortable with the neck areas fit on existing brand products. The reduction rate was also set differently on each part. For example, the reduction rate on outer side panel was set strongly to increase the breast's volume. Two products, developed by a 3D sports brassiere and previously released product, were worn on 8 subjects in their 20's to evaluate fit, comfort, and purchase preferences. The evaluation proved that newly developed 3D products were superior to comparative products. The results of the clothing pressure measurement indicate that the newly developed sports brassiere's front part had less pressure on upper bust and shoulder areas compared to comparative products as well as showed less pressure on the back side, which shows improved wearing comfort compared to comparative products.

Fall prevention strategies in community-dwelling older adults aged 65 or over with type 2 diabetes mellitus: a systematic review and meta-analysis

  • Hwang, Sujin;Woo, Youngkeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.4
    • /
    • pp.197-203
    • /
    • 2018
  • Objective: Independent walking is the most essential prerequisite to maintain quality of life in older persons. The purpose of this review was to investigate the effect of fall prevention strategies on fall risk for type 2 diabetes mellitus (T2DM) within community-dwelling older adults aged 65 and over. Design: A systematic review and meta-analysis. Methods: PubMed and three other databases were searched up to October 31st, 2018 and randomized controlled trials (RCTs) evaluating fall prevention strategies for fall risk in persons who were 65 years of age or above with T2DM were included. The review extracted the following information from each study selected: first author's surname, published year, country, study population, type of intervention, intensity of intervention, comparison, measurement variables, additional therapy, summary of results, and mean and standard deviation from selected studies. Results: This review selected fourteen RCTs with 460 older adults with diabetes mellitus. Of the 14 studies, the types of intervention used to improve the risk of falls were strengthening (5), aerobic exercises (2), multimodal exercises (4), one virtual reality exercise (1), whole body vibration with balance exercise (1), and Tai Chi exercise (1). Seven RCTs were eligible for the meta-analysis. Therapeutic interventions were more effective than the control group for the Timed Up-and-Go test (-1.11; 95% CI, -1.82 to -0.41) and the 6-minute Walk Test (-1.89; 95% CI, -8.33 to 4.54). Conclusions: The results of the review suggest that interventions to prevent fall risk in older adults with T2DM should focus on strengthening, balance, aerobic, and multimodal exercises.

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

Evaluation of Waist Circumference Cut-off Values as a Marker for Fatty Liver among Japanese Workers

  • Abe, Naomi;Honda, Sumihisa;Jahng, Doosub
    • Safety and Health at Work
    • /
    • v.3 no.4
    • /
    • pp.287-293
    • /
    • 2012
  • Objectives: Metabolic syndrome has received attention as a risk factor for cardiovascular disease, with particular importance attached to visceral fat accumulation, which is associated with lifestyle-related diseases and is strongly correlated with waist circumference. In this study, our aim is to propose waist circumference cut-off values that can be used as a marker for fatty liver based on a sample of workers receiving health checkups in Japan. Methods: This study was conducted in a total of 21,866 workers who underwent periodic health checkups between January 2007 and December 2007. The mean age of the subjects was 47.4 years for men (standard deviation [SD]: 8.0) and 44.7 years for women (SD: 6.9). Evaluation included abdominal ultrasound and measurement of waist circumference, body mass index, fasting blood glucose, triglycerides, high-density lipoprotein cholesterol, and blood pressure. Results: Based on receiver operating characteristic curve analysis, the optimal waist circumference cut-off values were shown as 85.0 cm (sensitivity 0.72, specificity 0.69) for men and 80.0 cm (sensitivity 0.75, specificity 0.78) for women. Conclusion: Abdominal ultrasound is the most efficient means of diagnosing fatty liver, but this examination seldom occurs because the test is not routinely performed at workers' health checkups. In people found to have a high risk of fatty liver, recommendations can be made for abdominal ultrasound based on the waist circumference cut-off values obtained in this study. That is, waist circumference can be used in high risk individuals as an effective marker for early detection of fatty liver.

A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography (이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구)

  • Kim, Eun Hye;Park, Hye Min;Kim, Jung Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.

Health Risk Assessment by Exposure to Heavy Metals in PM2.5 in Ulsan Industrial Complex Area (울산 산단지역 PM2.5 중 중금속 노출에 의한 건강위해성평가)

  • Ji-Yun Jung;Hye-Won Lee;Si-Hyun Park;Jeong-Il Lee;Dan-Ki Yoon;Cheol-Min Lee
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.108-117
    • /
    • 2023
  • Background: When particles are absorbed into the human body, they penetrate deep into the lungs and interact with the tissues of the body. Heavy metals in PM2.5 can cause various diseases. The main source of PM2.5 emissions in South Korea's atmosphere has been surveyed to be places of business. Objectives: The concentration of heavy metals in PM2.5 near the Ulsan Industrial Complex was measured and a health risk assessment was performed for residents near the industrial complex for exposure to heavy metals in PM2.5. Methods: Concentrations of heavy metals in PM2.5 were measured at four measurement sites (Ulsan, Mipo, Onsan, Maegok) near the industrial complexes. Heavy metals were analyzed according to the Air Pollution Monitoring Network Installation and Operation Guidelines presented by the National Institute of Environmental Research. Among them, only five substances (Mn, Ni, As, Cd, Cr6+) were targeted. The risk assessment was conducted on inhalation exposure for five age groups, and the excess cancer risk and hazard quotient were calculated. Results: In the risk assessment of exposure to heavy metals in PM2.5, As, Cd, and Cr6+ exceeded the risk tolerance standard of 10-6 for carcinogenic hazards. The highest hazard levels were observed in Onsan and Mipo industrial complexes. In the case of non-carcinogenic hazards, Mn was identified as exceeding the hazard tolerance of 1, and it showed the highest hazard in the Ulsan Industrial Complex. Conclusions: This study presented a detailed health risk from exposure to heavy metals in PM2.5 by industrial complexes located in Ulsan among five age groups. It is expected to be utilized as the basis for preparing damage control and industrial emission reduction measures against PM2.5 exposure at the Ulsan Industrial Complex.