• Title/Summary/Keyword: the single′ time use

Search Result 1,112, Processing Time 0.029 seconds

Object Dimension Estimation for Remote Visual Inspection in Borescope Systems

  • Kim, Hyun-Sik;Park, Yong-Suk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4160-4173
    • /
    • 2019
  • Borescopes facilitate the inspection of areas inside machines and systems that are not directly accessible for visual inspection. They offer real-time, up-close access to confined and hard-to-access spaces without having to dismantle or destructure the object under inspection. Borescopes are ideal instruments for routine maintenance, quality inspection and monitoring of systems and structures. The main application being fault or defect detection, it is useful to have measuring capability to quantify object dimensions in a target area. High-end borescopes use multi-optic solutions to provide measurement information of viewed objects. Multi-optic solutions can provide accurate measurements at the expense of structural complexity and cost increase. Measuring functionality is often unavailable in low-end, single camera borescopes. In this paper, a single camera measurement solution that enables the size estimation of viewed objects is proposed. The proposed solution computes and overlays a scaled grid of known spacing value over the screen view, enabling the human inspector to estimate the size of the objects in view. The proposed method provides a simple means of measurement that is applicable to low-end borescopes with no built-in measurement capability.

Influence of Smart Phone Use on Gait Pattern in Healthy Adults (스마트폰 사용이 건강한 성인의 보행패턴에 미치는 영향)

  • Moon, Jong-Hoon;Kim, Sung-Hyun;Na, Chang-Ho;Hong, Deok-Gi;Heo, Sung-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.199-206
    • /
    • 2018
  • This study was to investigate the Influence of smart phone use on gait in healthy adults. Twenty healthy adults were recruited in this study. All subjects performed twice for each normal gait and smart phone gait. The normal gait walked at their chosen speed, and the smart phone gait walked while watching the video. GAITRite system was used to identify the temporal and spatial variables related to the gait pattern during walking. Statistical analysis was analyzed by paired t-test. In comparison of temporal variables, smart phone gait was significantly lower in gait speed and cadence than in normal gait(p<.05), and was significantly longer in single support time and double support time(p<.05). In comparison of spatial variables, smart phone gait was significantly shorter in step length and stride length than in normal gait(p<.05) and significantly longer in step width(p<.05). The results of this study demonstrated that smartphone use can negatively affect the correct gait patterns during walking.

Direct displacement-based design accuracy prediction for single-column RC bridge bents

  • Tecchio, Giovanni;Dona, Marco;Modena, Claudio
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.455-480
    • /
    • 2015
  • In the last decade, displacement-based (DB) methods have become established design procedures for reinforced concrete (RC) structures. They use strain and displacement measures as seismic performance control parameters. As for other simplified seismic design methods, it is of great interest to prove if they are usually conservative in respect to more refined, nonlinear, time history analyses, and can estimate design parameters with acceptable accuracy. In this paper, the current Direct Displacement-Based Design (DDBD) procedure is evaluated for designing simple single degree of freedom (SDOF) systems with specific reference to simply supported RC bridge piers. Using different formulations proposed in literature for the equivalent viscous damping and spectrum reduction factor, a parametric study is carried out on a comprehensive set of SDOF systems, and an average error chart of the method is derived allowing prediction of the expected error for an ample range of design cases. Following the chart, it can be observed that, for the design of actual RC bridge piers, underestimation errors of the DDBD method are very low, while the overestimation range of the simplified displacement-based procedure is strongly dependent on design ductility.

Design of an Integrated High Voltage Pulse Generation circuit for Driving Piezoelectric Printer Heads (피에조일렉트릭 프린터 헤드 구동을 위한 집적화된 고전압 펄스 발생 회로의 설계)

  • Lee, Kyoung-Rok;Kim, Jong-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.80-86
    • /
    • 2011
  • This paper presents an integrated variable amplitude high voltage pulse generation circuit with low power and small size for driving industrial piezoelectric printer heads. To solve the problems of large size and power overhead of conventional pulse generators that usually assembled with multiple high-cost discrete ICs on a PCB board, we have designed a new integrated circuit (IC) chip. Since all the functions are integrated on to a single-chip it can achieve low cost and control the high-voltage output pulse with variable amplitudes as well. It can also digitally control the rising and falling times of an output high voltage pulse by using programmable RC time control of the output buffer. The proposed circuit has been designed and simulatedd in a 180[nm] Bipolar-CMOS-DMOS (BCD) technology using HSPICE and Cadence Virtuoso Tools. The proposed single-chip pulse generation circuit is suitable for use in industrial printer heads requiring a variable high voltage driving capability.

Learning Multidimensional Sequential Patterns Using Hellinger Entropy Function (Hellinger 엔트로피를 이용한 다차원 연속패턴의 생성방법)

  • Lee, Chang-Hwan
    • The KIPS Transactions:PartB
    • /
    • v.11B no.4
    • /
    • pp.477-484
    • /
    • 2004
  • The technique of sequential pattern mining means generating a set of inter-transaction patterns residing in time-dependent data. This paper proposes a new method for generating sequential patterns with the use of Hellinger measure. While the current methods are generating single dimensional sequential patterns within a single attribute, the proposed method is able to detect multi-dimensional patterns among different attributes. A number of heuristics, based on the characteristics of Hellinger measure, are proposed to reduce the computational complexity of the sequential pattern systems. Some experimental results are presented.

MATHEMATICAL ANALYSIS USING TWO MODELING TECHNIQUES FOR DYNAMIC RESPONSES OF A STRUCTURE SUBJECTED TO A GROUND ACCELERATION TIME HISTORY

  • Kim, Yong-Woo;Jhung, Myung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.43 no.4
    • /
    • pp.361-374
    • /
    • 2011
  • Two types of numerical modeling techniques were considered for the dynamic response of a structure subjected to a ground acceleration. One technique is based on the equation of motion relative to ground motion, and the other is based on the equation of absolute motion of the structure and the ground. The analytic background of the former is well established while the latter has not yet been extensively verified. The latter is called a large mass method, which allocates an appropriate large mass to the ground so that it causes the ground to move according to a given acceleration time history. In this paper, through the use of a single degree-of-freedom spring-mass system, the equations of motion of the two techniques were analyzed and useful theorems are provided on the large mass method. Using simple examples, the numerical results of the two modeling techniques were compared with analytic solutions. It is shown that the theorems provide a clear insight on the large mass method.

Acceleration of Simulated Fault Injection Using a Checkpoint Forwarding Technique

  • Na, Jongwhoa;Lee, Dongwoo
    • ETRI Journal
    • /
    • v.39 no.4
    • /
    • pp.605-613
    • /
    • 2017
  • Simulated fault injection (SFI) is widely used to assess the effectiveness of fault tolerance mechanisms in safety-critical embedded systems (SCESs) because of its advantages such as controllability and observability. However, the long test time of SFI due to the large number of test cases and the complex simulation models of modern SCESs has been identified as a limiting factor. We present a method that can accelerate an SFI tool using a checkpoint forwarding (CF) technique. To evaluate the performance of CF-based SFI (CF-SFI), we have developed a CF mechanism using Verilog fault-injection tools and two systems under test (SUT): a single-core-based co-simulation model and a triple modular redundant co-simulation model. Both systems use the Verilog simulation model of the OpenRISC 1200 processor and can execute the embedded benchmarks from MiBench. We investigate the effectiveness of the CF mechanism and evaluate the two SUTs by measuring the test time as well as the failure rates. Compared to the SFI with no CF mechanism, the proposed CF-SFI approach reduces the test time of the two SUTs by 29%-45%.

Comparison of the effects of transcutaneous electrical nerve stimulation, low level laser, and placebo treatment on temporomandibular joint disorders: a single-blind randomized controlled trial

  • Kim, Hyunjoong
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.244-251
    • /
    • 2020
  • Objective: Physical therapy techniques are required for patients with temporomandibular joint disorder (TMD), but the effects of treatment have not been compared. Therefore, effects of transcutaneous electrical nerve stimulation (TENS) and low level laser (LLL), which are most commonly used interventions, were compared. Design: Randomized controlled trial. Methods: Thirty-six participants with pain in the temporomandibular joint were enrolled, and 12 participants were randomly assigned to either the TENS group, LLL group, or placebo group. Each intervention was performed for a total of 6 sessions for 2 weeks. For the evaluation of the participants, the mouth opening (MO), pressure pain threshold (PPT), and stress were measured at three time periods: baseline, post-test, and follow-up at 2 weeks. Results: Significant interaction between groups according to each evaluation point was found only in PPT-masseter (p<0.05). The evaluation time point at which a significant difference appeared was at the post-test and follow-up at 2 weeks time periods. As a result of the post-test, the LLL group showed a significant improvement compared to the TENS group (p<0.05), and at 2 weeks follow-up, the TENS group showed a significant improvement compared to the placebo group (p<0.05). Conclusions: In this study, an experiment was conducted to compare the treatment effects when TENS, LLL, and placebo were given to patients with TMD. In addition, by quantitatively presenting the effect size of each treatment, this study suggests clinical use of TENS and LLL treatment for TMD.

The effect of gait training with an elastic ankle-foot orthosis on balance and walking ability of persons with chronic stroke: a randomized controlled trial

  • Chi, Ming Hao;Yim, Jong Eun;Yi, Dong hyun
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.222-229
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the effect of treadmill exercise on the posture and walking speed of chronic stroke survivors with an ankle-foot orthosis. Design: Randomized controlled trial. Methods: Twenty-four chronic persons with chronic stroke admitted to Bobath Memorial Hospital in Seongnam city were divided into two groups by random blind method. Treadmill exercise with an elastic ankle-foot orthosis was performed in the experimental group and treadmill exercise was performed in the control group. The experiment was carried out for 6 weeks, and the experiment was carried out three times a week for 20 minutes per session. To measure the effect, static balance was measured using the MTD system before and after training, and the Berg Balance Scale (BBS) was used to measure functional balance. Results: There was a statistically significant difference between the 2 groups in the BBS measurement results for confirming the functional balance (p<0.05). Also, there was a significant difference between the 2 groups in single limb support time, step time and step length (p<0.05). Conclusions: In this study, it was found that treadmill exercise with an elastic ankle-foot orthosis in persons with chronic stroke was effective in maintaining functional balance, walking ability, step length, and step time. Therefore, it is necessary to use a flexible ankle-foot orthosis with proper treadmill exercise as a method of improving balance and walking speed of chronic stroke survivors.

Costs involved in compliance with new endoscope reprocessing guidelines

  • David Hoffman;Christina Cool
    • Clinical Endoscopy
    • /
    • v.57 no.4
    • /
    • pp.534-541
    • /
    • 2024
  • Background/Aims: In March 2022, the Association for the Advancement of Medical Instrumentation (AAMI) released the American National Standards Institute (ANSI)/AAMI ST91:2021, their latest update on comprehensive, flexible, and semirigid endoscope reprocessing. These updated standards recommend the sterilization of high-risk endoscopes when possible and provide new recommendations for the precleaning, leak testing, manual cleaning, visual inspection, automated reprocessing, drying, storage, and transport of endoscopes. Methods: ANSI/AAMI ST91:2021 was compared with ANSI/AAMI ST91:2015 for major reprocessing differences that result in either time and/or cost increases. Time estimates were captured by explicit recommendation inclusion or taken from the literature. All the costs were estimated using publicly available resources. Results: The updated standards represent a potential 24.3-minute and 52.35 to 67.57 United States dollars increase per procedure in terms of reprocessing time and spending, respectively, not including capital investments. Capital costs per procedure were highly dependent on the procedure volume of the facility. Conclusions: The new AAMI standards recommend several major changes, such as sterilization, for facilities to reprocess and manage endoscopes between uses. As more facilities increase their reprocessing methods to reflect the updated standards, they do so at a cost and introduce several delays. As the reprocessing landscape evolves, facilities should consider their true costs and alternative solutions, such as single-use endoscopes.