• Title/Summary/Keyword: the reliability performances

Search Result 324, Processing Time 0.031 seconds

Review of the tracebility of ERA PD measuring system in test laboratory (시험소 부분방전 측정시스템(ERA)의 소급성검토)

  • Heo, J.C.;Kang, Y.S.;Kim, W.Y.;Oh, C.S.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1969-1971
    • /
    • 2004
  • For evaluation of partial discharge performances of electrical power appratus such as Insulator, circuit breaker and transformer and so on, Partial discharge measuring system(ERA) consisted of PD detector including amplifier, coupling capacitor, PD calibrator and voltage divider are used PD measuring system is very important factor which affect the test result and show reliability of test result in test laboratory, In this paper, we describe tracebility and uncertainty of PD measuring system in test laboratory based on IEC 60270.

  • PDF

THE DEVELOPMENT OF ULTRAHIGH VOLTAGE XLPE CABLE ACCESSORIES (초고압 XLPE 케이블 접속재 개발)

  • Bae, K.M.;Jeon, S.I.;Yoo, K.S.;Kweon, H.S.;Lee, K.H.;Lee, K.C.;Han, K.M.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.271-273
    • /
    • 1991
  • We have developed 154kV XLPE (Cross-linked Poly-ethylene) Cable accessories which show excellent performances. The results obtained from experiments using miniature model justified our electrical design and adopted materials, and assembly tests verified higher reliability of these accessories. Basic concepts of design and test, test results and failure analysis are presented.

  • PDF

Turbo Coded OFDM Scheme for a High-Speed Power Line Communication (고속 전력선통신 시스템의 터보 부호화)

  • Lee, Jae-Sun;Kim, Yo-Cheol;Kim, Jung-Hui;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.190-196
    • /
    • 2009
  • In this paper, performance of a turbo-coded OFDM system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, MAP (maximum a posteriori), Max-Log-MAP, and SOVA (soft decision Viterbi output) algorithms are chosen and their performances are compared. From simulation results, it is demonstrated that Max-Log-MAP algorithm is promising in terms of performance and complexity. It is shown that performance is substantially improved by increasing the number of iterations and interleaver length of a turbo encoder. The results in this paper can be applied to OFDM-based high-speed power line communication systems.

  • PDF

Simulation of interface ageing effect of suspension insulator using ANSYS (ANSYS를 이용한 현수애자의 계면팽창거동에 대한 해석)

  • Woo, B.C.;Han, S.W.;Cho, H.G.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.74-76
    • /
    • 2002
  • The suspension insulators are subjected to harsh environment in service for a long time. Long term reliability of the insulators is required for both mechanical and electrical performances. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing.

  • PDF

Performance of Double Binary Turbo Code for Power Line Communicaion Systems (고속 전력선통신 시스템의 비이진 터보 부호 성능)

  • Lee, Jae-Sun;Yang, Jae-Su;Woo, Sang-Kyu;Yoon, Byung-Wan;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.72-77
    • /
    • 2009
  • In this paper, performance of a turbo-coded PLC system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, Max-Log-MAP algorithms are chosen and performances are compared. The results in this paper can be applied to OFDM-based high-speed power line communication systems

  • PDF

Development of Vertical Barrel Type Multistage Pump (비속도 150급 수직배럴형 다단 원심펌프 개발)

  • Yoo, Il-Su;Park, Mu-Ryong;Hwang, Soon-Chan;Kim, Sung-Ki;Yoon, Eui-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • A vertical-axis multistage pump with low specific speed was developed, satisfying performance requirements such as flow rate, total head, and NPSH. The developed pump was designed through conceptual design, configuration design, and performance analysis by CFD which were established in KIMM. The prototype pump's mechanical wholesomeness besides hydraulic performances were verified by running test, performance test, and reliability test.

Review of the tracebility of impulse voltage measuring system in test laboratory (시험소 충격전압 측정시스템의 소급성검토)

  • Heo, J.C.;Choi, I.S.;Jeong, J.Y.;Ban, S.G.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1632-1634
    • /
    • 2003
  • For lihgtning and switching impulse voltage performances in laboratories, impulse voltage measuring system, which is consisted of voltage divider, recording instrument and connecting system between divider and recording instrument, is used. In order to show reliability of test result in test laboratory, tracebility of these measuring system to be using in test laboratory is needed. In this paper, we describe tracebility and uncertainty of impulse voltage measuring system in test laboratory.

  • PDF

Plastic Film Liquid Crystal Shutter and Its Application to 3D Stereoscopic Display

  • Kwon, Soon-Bum;Woo, Sung-Il;Im, Jang-Soon;Park, Seo-Kyu;Hwang, Won-Mi;Han, Jung-Hoon;Kim, Han-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.468-471
    • /
    • 2003
  • We firstly report liquid crystal shutter based on plastic film and its application to 3D shutter for stereoscopic displays. Plastic liquid crystal shutters have remarkable advantages compared to conventional glass liquid crystal shutters. They are thin, light and non-breakable so that very comfortable 3D shutter eye-wear can be realized using them. The concepts, optical performances and reliability test results of plastic film liquid crystal shutters are presented.

  • PDF

Development and application of integrated indicators for assessing the water resources performance of multi-purpose and water supply dams (댐 용수공급능력 안정성 평가를 위한 통합지표 개발 및 적용)

  • Sung, Jiyoung;Kang, Boosik;Kim, Bomi;Noh, Seongjin
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.9
    • /
    • pp.687-700
    • /
    • 2022
  • For comprehensively assessment the water resources performance of multi-purpose dams and water supply dams in South Korea, a methodology was proposed to utilize the durational reliability along with the integrated auxiliary indicators including resiliency, dimensionless vulnerability, water resource efficiency, specific inflow, and specific water supply. In addition, for the purpose of sustainable dam operation in the future, a plan to grade the water resources performance was presented to periodically evaluate the performance and determine the priority of each dam's structural or non-structural planning according to the evaluation results. As major results, in the case of Sumjingang Dam, the durational reliability was 99.0%, but the integrated auxiliary index was the lowest of 44 points, which was 5th grade. This means that despite the current high reliability, hydrological changes due to future climate change or regional change of water demand-supply balance can have significant impacts on the water resources performances. In contrast, the Chungju Dam with a durational reliability of 93.0%, which is below the average among all multi-purpose dams, shows the 76 points of the integrated auxiliary index, which is 3rd highest following the Soyanggang Dam and the Namgang Dam. Nevertheless, due to the size of the basin, the specific inflow is sufficiently high as 185%, so the actual performance could be evaluated relatively high. The water supply dams designed for a single purpose tend to be evaluated relatively high because they have a high proportion of industrial and municipal water supply and have enough room for the supply capacity.

Reliability Prediction of Failure Modes due to Pressure in Solid Rocket Case (고체로켓 케이스 내압파열 고장모드의 신뢰도예측)

  • Kim, Dong-Seong;Yoo, Min-Young;Kim, Hee-Seong;Choi, Joo-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.6
    • /
    • pp.635-642
    • /
    • 2014
  • In this paper, an efficient technique is developed to predict failure probability of three failure modes(case rupture, fracture and bolt breakage) related to solid rocket motor case due to the inner pressure during the mission flight. The overall procedure consists of the steps: 1) design parameters affecting the case failure are identified and their uncertainties are modelled by probability distribution, 2) combustion analysis in the interior of the case is carried out to obtain maximum expected operating pressure(MEOP), 3) stress and other structural performances are evaluated by finite element analysis(FEA), and 4) failure probabilities are calculated for the above mentioned failure modes. Axi-symmetric assumption for FEA is employed for simplification while contact between bolted joint is accounted for. Efficient procedure is developed to evaluate failure probability which consists of finding first an Most Probable Failure Point(MPP) using First-Order Reliability Method(FORM), next making a response surface model around the MPP using Latin Hypercube Sampling(LHS), and finally calculating failure probability by employing Importance Sampling.