• 제목/요약/키워드: the pass rate

검색결과 583건 처리시간 0.026초

방전드릴링에서 홀 관통 평가 방법 (A Method of Hole Pass-Through Evaluation for EDM Drilling)

  • 이철수;최인휴;허은영;김종민
    • 대한산업공학회지
    • /
    • 제38권3호
    • /
    • pp.220-226
    • /
    • 2012
  • The Electric discharge machining (EDM) process is used to minimize the difference between designed feature and machined feature while the most workpiece is removed through the cutting processes. The tiny-deep hole machining and perpendicular wall machining in mold and die are good applications of EDM. Among EDM equipment, the super drill uses the hollowed electrode to eliminate the debris which causes the second discharge with the electrode and degrades the machining quality. Through the hollow, the high pressured discharge oil is supplied to remove the debris together with the spindle rotation. The thin-hollow electrode tends to easily wear out compared to the sold die-sinking electrode and its wear rate is might not allowed to monitor in real time during discharging. Up to now, the wear amount is measured by off line method, which leads machining time to increase because the hole pass-through moment can be check by visual (manually) with the extra tool path. Therefore, this study suggests the attractive method to evaluate the hole pass-through moment in which the gap voltage and z-axis encoder pulse are monitored to predict the moment. The commercial super drill is used to validate the proposed method and the experiment is carried out.

CCHE2D모형을 이용한 보 상류에 퇴적된 토사의 배출 효과 분석 - 상주보와 구미보를 중심으로 - (Numerical Analysis of the Sediment Pass-Through from the Sangju Weir and the Gumi Weir by using CCHE2D)

  • 이경수;장창래;손광익;황만하
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.813-824
    • /
    • 2013
  • In this study, sediment pass-through (SPT) from the Sangju Weir and Gumi Weir in the Nakdong River is analyzed numerically using CCHE2D. Sediment delivery is analyzed to predict the sediment discharge rate in the Sangju Weir and Gumi Weir. The sediment discharge from the Sanju Weir is 4,381 tons in the inflow of $3,857m^3/s$, which are 2 year frequency discharge, for 48 hours, and the sediment discharge is 2,766 tons in the inflow of $1,500m^3/s$. The maximum sediment delivery occurs in the immediate downstream of the weir. The sediment discharge from the Gumi Weir is 3,216 tons in the inflow of $5,400m^3/s$, which are 2 year frequency discharge, for 48 hours, and the sediment discharge is 73 tons in the inflow of $3,857m^3/s$. The maximum sediment delivery occurs in the weir. Therefore, the effectiveness of sediment delivery is high in the condition of the 2 year frequency discharge and the gate in the weirs fully are opened.

어린이 급식소의 배식용기 표면에 대한 ATP(Adenosine Triphosphate) 위생 모니터링 가이드라인 설정 (Setting Guidelines for ATP Bioluminescence Hygiene Monitoring of Distribution Trays in Used Children's Foodservices)

  • 문혜경
    • 대한영양사협회학술지
    • /
    • 제26권4호
    • /
    • pp.243-253
    • /
    • 2020
  • The purpose of this study was to set new guidelines for adenosine triphosphate (ATP) bioluminescence hygiene monitoring of distribution trays at children's foodservices. Five dietitians visited 223 foodservices (95 institutional, 128 small) to examine whether they adhered to the norms of 'Keeping distribution tray sanitary by washing/sanitizing' and 'Performing food distribution in a clean and appropriate way'. In this visit, dietitians swabbed 100 ㎠ area of the distribution trays twice, once for obtaining ATP measurements and the second time for Aerobic Plate Counts (APC) using 3M Petrifilm Plates. Chi-square test and ANOVA were applied using SPSS 23.0 software. SPSS 23.0 was used to conduct graphical and statistical analysis of the raw data of ATP measurements, which were further transformed by a Box-Cox transformation. The mean of APC from all the subjects inspected was 3.8×102±2,102.0 CFU/100 ㎠. A total of 208 (93.3%) trays were observed within the acceptable limits of APC (Pass<5.0×102 CFU/100 ㎠). APCs taken at institutional foodservices showed significantly lower levels (1.4×102±600.0 CFU/100 ㎠, P<0.01) compared to the small foodservices (5.5×102±2,718.7 CFU/100 ㎠). No significant differences were observed between the two groups in ATP measurements and in the performance rate of 2 checklist items. As against the 93.3% APC adequacy from the total subjected inspection, total ATP adequacy (Pass≤300 RLU/100 ㎠) was only 71.7%. Therefore, more practical guidelines should be prepared for the assessment of the hygiene of distribution trays. In the graphical and statistical analysis, levels below 250 RLU/100 ㎠ was considered 'Pass', while equal to or greater than 350 RLU/100 ㎠ was considered 'Fail' for distribution trays.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

수도권 외국인 전용 교통카드 문제점과 개선 방향 (Problems and Directions for Improving Transportation Cards Exclusively for Foreigners in the Metropolitan Area)

  • 이태림;김시곤
    • 대한토목학회논문집
    • /
    • 제42권3호
    • /
    • pp.391-398
    • /
    • 2022
  • 외국인 관광객의 편의를 제공하기 위하여 개발 판매되었던 M-pass(왹국인 전용카드)의 이용률은 최근5년간 서울방문객의 0.051 %에 불과 하였다. 이렇게 저조한 판매마저도 코로나 19로 인하여 2020년 경우 0.024 % 수준으로 하락하였다. 성과부진의 원인은 국토부와 카드발행사가 교통운영기관을 배제하고 추진하였고 홍보부진과 가격결정의 불합리성, 소수의 판매장소 한정 등이 문제점으로 나타났다. 이러한 문제를 해결하기 위하여 Digital Matketing 체계의 구축과 함께 모든 관련기관의 참여와 의견이 반영된 새로운 상품 개발 등의 경영전략이 필요한 것으로 연구결과 나타났다. 본 연구로 포스트코로나 시대 외국인 서울관광객의 편의 제공 뿐만아니라 지하철 운영기관의 경영개선에 도움이 될 수 있기를 기대 한다.

마이크로파이프라인 구조의 16bit 비동기 곱셈기 (Asynchronous 16bit Multiplier with micropipelined structure)

  • 장미숙;이유진;김학윤;이우석;최호용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.145-148
    • /
    • 2000
  • A 16bit asynchronous multiplier has been designed using micropipelind structure with 2 phase and data bundling. And 4-radix modified Booth algorithm, CPlatch(Cature-Pass latch) and modified 4-2 counters have adopted in this design. It is implemented in 0.65$\mu\textrm{m}$ double-poly/double-metal CMOS technology by using 12,074 transistors with core size of 1.4${\times}$1.8$\textrm{mm}^2$. And our design results in a computation rate 55MHz a supply voltage of 3.3V.

  • PDF

계절 및 회원 특성이 공공자전거 통행에 미치는 영향분석 : 서울시 따릉이를 대상으로 (Effects of Seasonal and Membership Characteristics on Public Bicycle Traffic : Focusing on the Seoul Bike)

  • 장재민;이숭봉;이영인;이무영
    • 한국도로학회논문집
    • /
    • 제20권4호
    • /
    • pp.47-58
    • /
    • 2018
  • PURPOSES : Seoul introduced public bicycles to reduce environmental pollution and create a healthy society. Because the use of bicycles is highly weather dependent, and bicycles are rented by the people, member characteristics and seasonal influences should be considered. This study analyzed bicycle traffic characteristics considering seasonal and member characteristics and highlighted some implications. METHODS : The Yeouido and Sangam districts, which have multiple business districts, were taken as the areas of interest. In order to reflect seasonal and membership characteristics, the traffic volume, time of use, and characteristics of each zone were categorized by season (spring, summer, autumn, winter) and membership type (season, daily, group). In addition, we analyzed the pattern of traffic volume and usage time according to the traffic purpose after separating rental locations into residential, business, subway, and park, reflecting the land characteristics. RESULTS : The results revealed that seasonal characteristics were high for bicycle traffic, time of use, and occupancy rate for park locations in spring and autumn. In terms of membership characteristics, group and daily users appeared as major visitors for park locations, and the trends of commuter pass users showed that bicycle use meets the purpose of introducing public bicycles. CONCLUSIONS : Traffic characteristics differed according to seasonal and membership characteristics. It is necessary to involve and extend the users of the commuter pass. Situations in which commuter pass users cannot function as a group or in which daily users monopolize bicycles (especially near parks, near subway stations, etc.) must be avoided.

자기공명 Tailored-RF 경사자계반향영상법을 이용한 고양이 뇌에서의 First-Pass관찰 (First-Pass Observation using Tailored-RF Gradient Echo (TRFGE) MR Imaging in Cat Brain)

  • 문치웅;노용만
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.209-216
    • /
    • 1995
  • Recently, a new tailored RF gradient echo (TRFGE) sequence was reported. This technique not only enhances the magnetic susceptibility effect but also allows us to measure local changes in brain oxygenation. In this study, a phantom and cat brain experiments were performed on a 4.7 Tesla BIQSPEC (BRUKER) instrument with a 26 cm gradient system. We have demonstrated that the signal intensity (SI) of the TRFGE sequence varies according to the concentration of susceptibility contrast agent. Three capillary tubes with different concentrations of Gd-DTPA (0.01, 0.05, 0.1 mMOI/l) were placed at the middle of a cylindrical water phantom. Using both TRFGE and conventional gradient echo (CGE) sequences, phantom images of the slices which contain all three tubes were obtained. For the animal experiment, cats were anesthetized and ventilated using halotane (0.5%) and a $N_2O/ O_2$ mixture (2:1), and blood pressure and heart rate were monitored and kept normal. For the observation of tue first pass of Gd- DTPA, imaging was started at t = 0. At t = 8 ~ 12s, 0.2 mMol/Kg Gd-DTPA was manually injected in the femoral vein. The imaging parameters were TRITE = 25/10 msec, flip angle = $30^{\circ}$, FOV = 10cm, image matrix size = $128{\times}128$ with 64 phase encodings and the image data acquisition window was 10 msec. SI-time curves were then obtained from a series of 30 images which were collected at 2 sec intervals using both CGE and TRFGE pulse sequences before, during, and following the contrast injection.

  • PDF

에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석 (Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving)

  • 김지혜;이경혁;임재림
    • 멤브레인
    • /
    • 제29권6호
    • /
    • pp.314-322
    • /
    • 2019
  • 기후변화로 인해 가속화되고 있는 충남 지역 가뭄현상에 대응하고 대산 임해산업단지의 증가하는 용수 수요를 만족하기 위해서, K-water에서는 100,000 ㎥/일 규모 역삼투 해수담수플랜트 건설 사업을 추진하고 있다. 이에 본 연구에서는 해수담수플랜트 운영비용의 70% 이상을 담당하는 역삼투 공정 성능에 영향을 미치는 주요 인자에 대한 성능 분석을 수행하였다. 대산 지역 해수 염분농도 및 수온 변화 조건에서 RO 공정의 전력소모는 2.39 ± 0.13 kWh/㎥로 나타났으며, 막여과유속과 회수율이 낮을수록 전력소모가 절감되어 연간 운영비용이 감소하였다. 주요 막 제조사별 고유량 막의 성능 비교 결과, 전량 2단 여과공정(full two pass) 기준 생산수 TDS는 평균 3.84 mg/L로 양호하였고, 전력소모는 2.22 ± 0.13 kWh/㎥ 수준으로 확인되었다. 역삼투 공정 구성을 전량 2단 여과방식에서 partial 또는 split partial 방식으로 변경함에 따라 전력소모는 최대 0.29 kWh/㎥, 막모듈 설치비용은 최대 15.6% 절감 가능할 것으로 기대된다.

하이패스 DSRC 기반의 경로통행시간 산정을 위한 공간적 집계방안 산정에 관한 연구 (A Study on Spatial Aggregation Method for Path Travel Time Estimation using Hi-Pass DSRC System)

  • 이환필;심상우;최윤택;김동인
    • 한국도로학회논문집
    • /
    • 제16권3호
    • /
    • pp.119-129
    • /
    • 2014
  • PURPOSES : This investigational survey is to observe a proper spatial aggregation method for path travel time estimation using the hi-pass DSRC system. METHODS : The links which connect the nodes of section detectors location are used for path travel time estimation traditionally. It makes some problem such as increasing accumulation errors and processing times. In this background, the new links composition methods for spatial aggregation are considered by using some types of nodes as IC, JC, RSE combination. Path travel times estimated by new aggregation methods are compared with PBM travel times by MAE, MAPE and statistical hypothesis tests. RESULTS : The results of minimum sample size and missing rate for 5 minutes aggregation interval are satisfied except for JC link path travel time in Seoul TG~Kuemho JC. Thus, it was additionally observed for minimum sample size satisfaction. In 15, 30 minutes and 1 hour aggregation intervals, all conditions are satisfied by the minimum sample size criteria. For accuracy test and statistical hypothesis test, it has been proved that RSE, Conzone, IC, JC links have equivalent errors and statistical characteristics. CONCLUSIONS : There are some errors between the PBM and the LBM methods that come from dropping vehicles by rest areas. Consequently, this survey result means each of links compositions are available for the estimation of path travel time when PBM vehicles are missed.