• Title/Summary/Keyword: the optimum water absorption ratio

Search Result 66, Processing Time 0.029 seconds

Dynamic Analysis of an Ammonia-Water Absorption Chiller (암모니아-물 흡수식 냉각기의 동적 해석)

  • Kim Byong Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.990-998
    • /
    • 2004
  • Dynamic behavior of an ammonia-water absorption system was investigated numerically. Thermal-hydraulic model for a single-effect 3 RT chiller was developed by applying transient conservation equations of total mass, $NH_3$ mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analyses were performed to quantify the effects of bulk concentration and charging ratio on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum charging ratio and bulk concentration were to found to exist, which resulted in the maximum cooling capacity and COP. The time constant increased as the charging ratio increased, but decreased with the increase of bulk concentration.

Manufacturing Water Permeable Block Using Loess, Clay and Waste Sewage Sludge (황토, 점토 및 하수처리오니를 이용한 투수블록 제조)

  • Kim, Jong Dae;Han, Sang Moo;Jeong, Byung Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.476-481
    • /
    • 2015
  • Water permeable block was manufactured using waste sewage sludge, loess and clay for the purpose of recycling waste sludge due to the prohibition of waste sludge ocean dumping. Experiments for determining optimum mixing ratio was conducted by changing sludge content in water permeable block as 5~20%. In respect of compressive strength, $1,600N/cm^2$ ($163.3kg/cm^2$) was obtained when the mixing ratio of sludge : loess : clay were maintained by 5% : 65% : 30%, 10% : 65% : 25% and 15% : 65% : 20%, respectively. These mean that relatively high compressive strength can be obtained when the sludge content is maintained 5, 10, 15% at the 65% of loess content. In terms of water permeability and absorption rate, the higher values can be obtained as the sludge content increases. The optimum mixing ratio of sludge : loess : clay came out to be 15% : 65% : 20% when water permeability, absorption and strength were considered altogether, which matches the result observed by an electron microscope. The heavy metal leaching test result of the prepared permeable block appeared to satisfy the environmental standard in the content of Cd, Cu, Pb and As.

A Study on Stress-Strain Characteristics of Compacted Bentonite for High-Level Radioactive Waste Repository (고준위폐기물 차폐용 압축벤토나이트의 응력-변형률 거동 분석)

  • Kim, Do-Hyun;Jeong, Sang-Seom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.792-797
    • /
    • 2009
  • The stress-strain characteristics of compacted bentonite are investigated using experimental triaxial compression test by Hoek-cell. Special attention given to various dry density and water absorption ratio. Based on the test results, it is shown that the stress-strain relationship of compacted bentonite is highly influenced by dry density and water absorption ratio. Also, characteristics of Bentonite is similar to the clay rather than sand. Strength of compressed Bentonite increases with higher dry density. It shows maximum strength value, if in a same condition with dry density and constrain pressure. So we determine that value as the optimistic moisture contents for the maximun strength of compressed Bentonite.

  • PDF

Studies on Absorption Ratio of Tobacco for Optimum Moisture Control (적정수분 관리를 위한 담배흡습속도에 관한 연구)

  • 정한주;김기환;민영근;김병구;양광규;오인혁
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.1
    • /
    • pp.90-97
    • /
    • 1993
  • 1. Average moisture content of tobacco in BIB silo was about 19: 1% until 4hours conditioned time, and then moisture variation of tobacco after 2hr conditioned was very small. 2. Application of mathematical model for ordering system. 1) The constant K in the exponential equation varies inversely with both relative humidity and equilibrium moisture. 2) Time needed to order blending tobacco leaves with standard moisture from bulking and blending silo was 4 hours. 3) Reconstituted tobacco sheet had higher moisture absorption ratio than Oriental and Burley tobacco. 4) For minimize of conditioning time in BIB silo, the values of K and Mo given in this study can be used in equation(1) to calculate moisture absorption ratio and optimum conditioning time. 3. Average moisture content and water activity of conditioned tobacco for 4 hours in BIB silo was about 20% and 0.65. In this condition. microbial life will inhibite 4. Physical properties of conditioned tobacco in bulking and blending silo for 4hours was virtually no change.

  • PDF

Varietal Difference in Water Absorption Characteristics of Milled Rice, and Its Relation to the Other Grain Quality Components

  • Hae Chune, Choi;Jeong Hyun, Chi;Soo Yeon, Cho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.3
    • /
    • pp.288-295
    • /
    • 1999
  • Nineteen japonica and Tongil-type rices were selected from seventy nine Korean and Japanese rice cultivars grown in 1989 based on the water uptake behavior of milled rice under the room temperature and boiling conditions. The selected rice cultivars were investigated for water absorbability and some physicochemical characteristics of milled rice, proper water amount for cooking and sensory evaluation of cooked rice. The relationships among the tested grain properties were also examined. The highest varietal variation of water uptake rate was observed at twenty minutes after soaking in water. The maximum water uptake of milled rices at room temperature occurred mostly at about eighty minutes after soaking in water. Newly harvested rices showed a significantly lower water uptake rate of milled rice at 20 minutes after soaking, a relatively higher maximum water absorption ratio under the room temperature, and the less water uptake and volume expansion of boiled rice compared with the one-year old rice samples. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice ansd the palatability of cooked rice. The water/rice ratio(in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was averaged to 2.63(in v/v basis). The water amount needed for optimum cooking was the lowest in Cheongcheongbyeo (Tongil-type rice) and the highest in Jinbubyeo, and the amount could be estimated with about 70% fittness by the multiple regression formula based on some water uptake characteristics, ADV and amylose content of milled rice as the independent variables. Nineteen rice cultivars were classified into seven groups based on scatter diagram projected by principal component analysis using eight properties related to water uptake and gelatinization of milled rice.

  • PDF

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

Thermodynamic Analysis of an Absorption Heat Pump Heating System with LiBr-Water Solution (2 중효용 흡수식 히트점프의 난방 성능 해석)

  • Won, S.H.;Lee, W.Y.;Chung, H.S.
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.73-80
    • /
    • 1989
  • This paper presents as assessment based on steady-state thermodynamic analysis and computer modeling of a double effect generation absorption heating cycle for solar air-conditioning to find operating temperature ranges. The influences of component temperatures on the heating coefficients of performance and mass flow ratio have been investigated to obtain optimum operating conditions for the proposed air conditioning system. And the single and double effect absorption cycles are compared with each other over the same range of temperatures.

  • PDF

Simulation of the Characteristics of High-Performance Absorption Cycles (고성능 흡수냉동 사이클의 특성 시뮬레이션)

  • 윤정인;오후규;이용화
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

Simulation of a two-stage absorption heat pump cycle using treated sewage (하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션)

  • 이용화;신현준;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF

Transdermal Delivery of Diclofenac Using Microemulsions

  • Kweon, Jang-Hoon;Chi, Sang-Cheol;Park, Eun-Seok
    • Archives of Pharmacal Research
    • /
    • v.27 no.3
    • /
    • pp.351-356
    • /
    • 2004
  • A transdermal preparation containing diclofenac diethylammonium (DDA) was developed using an O/W microemulsion system. Of the oils tested, lauryl alcohol was chosen as the oil phase of the microemulsion, as it showed a good solubilizing capacity and excellent skin permeation rate of the drug. Pseudoternary phase diagrams were constructed to obtain the concentration range of oil, surfactant and cosurfactant for microemulsion formation, and the effect of these additives on skin permeation of DDA was evaluated with excised rat skins. The optimum formulation of the microemulsion consisted of 1.16% of DDA, 5% of lauryl alcohol, 60% of water in combination with the 34.54% of Labrasol (surfactant)/ethanol (cosurfactant) (1:2). The efficiency of formulation in the percutaneous absorption of DDA was dependent upon the contents of water and lauryl alcohol as well as Labrasol: ethanol mixing ratio. It was concluded that the percutaneous absorption of DDA from microemulsions was enhanced with increasing the lauryl alcohol and water contents, and with decreasing the Labrasol:ethanol mixing ratio in the formulation.