A Suggestions for Building Regulation through the Analysis of Problems among the Building Evacuation Laws (건축물 피난규정간 문제점 분석을 통한 법령 개선방향 설정에 관한 연구)

  • Hwang, Eun-Kyoung;Kim, Dae-Hee;Cho, Jeong-Hoon;Hwang, Keum-Sook
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.105-114
    • /
    • 2007
  • Recently the consideration for occupants' security has been raised as very important design element from the fire by building's large sized, higher storied, and its compounded. But the domestic Laws regulated the predicative laws according to the technical standard which has no difference from the past domestic evacuation regulations. Therefore when big fire occurs, it is not enough to guarantee for occupants to escape safely. Specially since domestic escape relevant laws are divided into Architect relevant law and fire fighting relevant law, it has caused to bring various problems. So This study will show the problems of the evacuation regulation which is registrated in the Architect relevant law and fire fighting relevant law. And also later, when Architect escape relevant laws re-registrate, this study will be used as foundational materials.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

A Study on Improvement of Evacuation Safety at Daycare Center (어린이집 피난안전 향상에 관한 연구)

  • Jin, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.63-73
    • /
    • 2017
  • As more and more the number of a couple working together for living has increased and an interest in early education has risen, daycare centers have made an effort to provide effective and good service beyond 'nursery care'. The most important thing in building in the event of disasters is safe evacuation of occupants. Having 'safe evacuation route' is required to reduce damage caused by disasters, It is necessary to give continuous and repeated training for right evacuation to infant and children so that they can evacuation successfully. This study examined problems that need improvement so that evacuation instrument installed in daycare centers can be used better by analyzing a survey of evacuation related facilities on daycare centers. This study found that laws and regulations on safety should be improved, evacuation facilities prepared against should be maintained regularly by relevant authorities, training for coping with disasters should be provied and evacuation instruments which are suitable for children.

Analysis of Institutional Limitations on Evacuation of Urban Railway Station Facilities and Guidelines (도시철도역 시설의 피난에 대한 제도적 한계점 분석과 가이드라인)

  • Yekyeong Shin;Okkyung Yuh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • This study analyzes the institutional status related to 'evacuation' and 'firefighting' in underground subway stations, derives institutional limitations for 'evacuation' in underground subway stations, and proposes guidelines in terms of architectural space based on this. As a result of the study, the following points were derived. First, since similar standards are separately enacted in individual laws and it is difficult to grasp the standards and they are dualized, it is necessary to standardize and regulate the space where users stay according to the movement of urban railway users, limited to urban railways. Second, in order to use trains, a special procedure called 'ticketing' must be considered, and regulations on evacuation safety zones and evacuation stairs between the waiting room and the platform are required. Finally, if there is a platform at a depth of more than 30m underground, it is necessary to install an evacuation floor in accordance with standards similar to the current building law.

Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment (노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석)

  • Lee, Sang Im;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.869-878
    • /
    • 2021
  • This study is a study on 11-story apartments that increase the event of fires in old apartments where building-related laws and regulations are not retroactively applied. As a result of analyzing the risk of installing fire doors in Improvement Scenario 2-4, assuming that fire doors are installed as basic scenario 1 in the existing situation where fire doors are not installed at the entrance of direct stairs. In basic scenario 1, the visible distance to the entrance of the direct staircase due to the spread of smoke was 260 seconds. Improvement scenarios 3 to 4 with fire doors installed open 300 seconds after the fire was recognized, and when the fire doors were installed at the entrance of the direct stairs, the visibility to the entrance of the statistics team was less than 600 seconds. In this case, the visibility was 600 seconds at the time of installation of the fire door, and scenarios 3 to 4 increased 56.6% compared to scenario 1, lowering the risk of evacuation by more than 50%. In order to eliminate the risk of non-installation of direct statistical groups that increase the risk of smoke spread, building-related laws such as the Fire Fighting Act shall be retroactively applied when installing a direct stairway entrance or balcony folding evacuation system. The improvement caused by the installation of fire doors has numerically proven the necessity of fire doors during evacuation, and the importance of maintaining fire doors can be grasped.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.