The aim of this study was to investigate the relationship between velocity and factors which could affect the velocity of mandibular movement. For this study, 30 dental students without any masticatory signs and symptoms and 90 patients with temporomandibular disorders(TMD) were selected as the control group and the patients group, respectively. After determining Angle's classification and lateral guidance pattern of occlusion, clinical examination for TMD was perfomed. Velocity and distance of mandibular movements were recorded with BioEGN, reproducibility index of lateral excursions was evaluated by Pantronic(PRI) and BioEGN (BERI) activity in masticatory and cervical muscles were measured with BioEMG, and occlusal contact time and cross-arch unbalance(Total left-right statistics, TLR) on clenching were recorded with T-scan, respectively. The results of this study were as follows : 1. Velocity in the patients was faster than that in the controls in most mandibular movements, but on wide opening and closing movement, result was reverse. 2. Velocity on closing movements were faster than that on opening movements in the control group and a similar tendency was also shown in the patients group. 3. Patients with muscle disorders showed a tendency to have the highest value of velocity of all diagnostic subgroups, while patients with degenerative joint diseases showed a tendency to have the lowest value. 4. Patients with canine guidance showed a tendency to have the highest value of velocity in three subgroups by lateral guidance pattern, while patients with group function showed a tendency to have the lowest value. 5. BERI had a positive correlation with opening velocity on lateral excursion, while TLR had a negative correlation with opening velocity on swallowing. 6. EMG activity on clenching in masticatory muscles had negative correlation with opening velocity on border movements, and on swollowing, while the activity in rest correlated positively with opening velocity on border movements. 7. There were positive correlation between the velocity and the distance in long components of mandibular trajectory.
International Journal of Fluid Machinery and Systems
/
v.10
no.2
/
pp.154-163
/
2017
Performance characteristics in pump mode of pump-turbines are vital for the safe and effective operation of pumped storage power plants. However, the head characteristics are different under different guide vane openings. In this paper, 3-D steady simulations were performed under 13mm, 19mm and 25mm guide vane openings. Three groups of operating points under the three GVOs were chosen based on experimental validation to investigate the influence of guide vane setting on flow patterns upstream and downstream. The results reveal that, the guide vane setting will obviously change the flow pattern downstream, which in turn influences the flow upstream. It shows a strong effect on hydraulic loss (power dissipation) in the guide and stay vanes. It is also found that the hydraulic loss mainly comes from the flow separation and vortices. In addition, in some operating conditions, the change of guide vane opening will change the flow angle at the runner inlet and outlet, which will change the Euler momentum (power input). The joint action of Euler momentum and hydraulic loss results in the change of the head characteristics.
This paper presents a new algorithm about motion adjustment for dynamic balance. It adjusts an unbalanced motion to an balanced motion while preserving the nuance of original motion. We solve dynamic balancing problem using the zero moment point (ZMP) which is often used for controlling the balance of biped robot. Our algorithm is consists of four steps. First, it fits joint angle data to spline curves for reducing noise. Second, the algorithm analyzes the ZMP trajectory so that it can detects the dynamically-unbalanced duration. Third, the algorithm project the ZMP trajectory into the supporting area if the trajectory deviates from the area. Finally, the algorithm produces the balanced motion that satisfies the new ZMP trajectory. In this step, the constrained optimization method is used so that the new motion keeps the original motion characteristics as much as possible. We make several experiments in order to prove that our algorithm is useful to add physical realism to a kinematically edited motion.
Background: Squatting is one of the best functional exercises to strengthen the quadriceps muscle in independent gait and activities of daily living. Although the use of a gym ball during squat exercise is the most common way of strengthening the vastus medialis oblique (VMO) muscle, published data on this subject are limited. Objects: The purpose of this study was to compare the sequential muscle activation of the VMO and vastus lateralis (VL) muscles during squat exercise using a gym ball at different knee flexion angles. Methods: Forty healthy adults were randomly divided into experimental (squat exercise using a gym ball) and control (squat exercise alone) groups, in which squats were performed at $45^{\circ}$ and $90^{\circ}$ knee flexion. Electromyographic (EMG) activity data were collected over 10 seconds under the 2 angles of knee flexion ($45^{\circ}$ and $90^{\circ}$). Results: There was significant group and time interaction effect for VMO and VL muscle activation at $45^{\circ}$ knee flexion. This was similarly demonstrated at $90^{\circ}$ knee flexion. No significant group main effect and time main effect for VMO and VL muscle activation were noted at $45^{\circ}$ knee flexion, respectively. In contrast, there was significant group main effect and time main effect for VMO and VL muscle activation at $90^{\circ}$ knee flexion. These significant differences were demonstrated through two-way analysis of variance over repeated measurements, suggesting that the EMG activity of the VMO muscle during squatting with a gym ball showed remarkable improvement compared to that of the VL muscle. Conclusion: This research suggests that squat exercise using a gym ball may be more beneficial in improving the activity of VMO than of the VL muscle at both $45^{\circ}$ and $90^{\circ}$ of knee flexion, respectively. We highly recommend squat exercises with a gym ball for selective strengthening of the VMO muscle in knee rehabilitation.
Purpose: The purpose of this study was to analyze the clinical results of medial horizontal suture fixation of Akin osteotomy in hallux valgus and present its advantages. Materials and Methods: This study was based on 48 cases of 35 patients with Akin osteotomy, who underwent surgery of hallux valgus between December 2014 and July 2015, and with at least 12 months of follow-up. The mean age of patients was 46.9 years (range, 16~71 years). The mean follow-up duration was 15.9 months (range, 12~18 months). Clinical evaluations included pain visual analogue scale (VAS) score, American Orthopaedic Foot and Ankle Society (AOFAS hallux metatarsophalangeal interphalangeal scale) score, and satisfaction score. Weightbearing anteroposterior radiographs were taken to measure the distal articular set angle (DASA) of the hallux. Radiographic bone union at 6 months follow-up was regarded as a success, while a loss of reduction and nonunion was regarded as a failure. Results: The mean pre- and postoperative pain VAS scores were 4.27 and 1.67, respectively (p<0.05). The mean AOFAS score improved from 59.7 to 80.5 (p<0.05). The DASA was improved from 8.15 to -2.57 (p<0.05). There was no case of skin irritation, cortical breakage, inflammation from the knot, and infection. All patients showed union without fixation failure. Conclusion: The clinical and radiological evaluations in this study demonstrate reliable results without complication. The medial horizontal suture fixation of the Akin osteotomy was effective, and the advantage of this procedure was unnecessity of the material removal, preservation of the joint, and no skin irritation.
The Sit-and-Reach Test (SRT) is commonly nea to assess flexibility of the spine and length of the hamstring muscle, The purpose of this study was to describe hamstring muscle length as reflected by use of the SRT, the Hip Joint Angle (HJA) and Sack length(from C7 to S2) in children, to examine the correlation between Back length, SRT and HJA measurements and to examine gender differences. The 162 subjects were participated without known musculoskeletal and neurological impairments of their spine or lower exeremities. In the Long-silting position, the Back length, SRT and HJA measurements were obtained. A mean Back length value of 46.2cm, a mean SRT value of 29.4cm and a mean HJA of 77,0 degrees were obtained including all subjects. There was a strong correlation between the SRT and HJA measurements (r=.66). There were a difference between boys and girls in Back(p=.0019) and HJA measurements (p=.015). The results of this study suggest that measurements for the SRT and HJA were correlated than Back. The HJA measurements guide treatment more effectively than do Back length and SRT measurements.
Kim, Yongrak;Park, Yunsik;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
Journal of Veterinary Clinics
/
v.33
no.5
/
pp.295-299
/
2016
A 2-year-old, 1.94 kg spayed female Toy Poodle was referred for revision surgery for patellar reluxation following surgery for bilateral medial patellar luxation (MPL). Intermittent non-weight-bearing lameness of the right hindlimb and weight-bearing lameness of the left hindlimb were evident on general inspection. A physical examination revealed that there was a bilateral grade 4 MPL. On radiographs, the medial and lateral trochlear ridge was bilaterally worn out. Patellar groove replacement (PGR) was performed in two stages to replace the bilateral femoral trochlea that had a severely worn out groove. Corrective femoral osteotomy with increasing anteversion angle, tibial tuberosity transposition, medial releasing, lateral imbrications and PGR were performed on the right hindlimb. Six months after surgery on the right hindlimb, a PGR prosthesis was positioned medially on the frontal plane and tibial tuberosity transposition and lateral imbrications were performed on the left hindlimb. Two weeks after surgery, reluxation of the patella occurred on the left hindlimb. The tibial tuberosity transposition was performed to realign the patella more laterally than the previous surgery, and a patellar sling was applied. Two years after the last surgery, the patient showed no pain on the stifle joint and satisfactory weight-bearing ambulation. Reluxation did not recur. PGR maybe a successful treatment for dogs with iatrogenically damaged and/or worn out patellar grooves.
Purpose: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). Materials and Methods: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB $Mercuray^{TM}$ (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with $Vimplant2.0^{TM}$ (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. Results: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p< 0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was $79.6{\pm}2.7^{\circ}\;and\;80.1{\pm}5.7^{\circ}$ respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. Conclusion: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.
The Journal of the Institute of Internet, Broadcasting and Communication
/
v.21
no.6
/
pp.155-161
/
2021
Gesture recognition analytics through a camera in real time have been widely studied in recent years. Since a small number of features from human joints are extracted, low accuracy of classifying models is get in conventional gesture recognition studies. In this paper, CBAM (Convolutional Block Attention Module) with high accuracy for classifying images is proposed as a classification model and algorithm calculating the angle of joints depending on actions is presented to solve the issues. Employing five exercise gestures images from the fitness posture images provided by AI Hub, the images are applied to the classification model. Important 8-joint angles information for classifying the exercise gestures is extracted from the images by using MediaPipe, a graph-based framework provided by Google. Setting the features as input of the classification model, the classification model is learned. From the simulation results, it is confirmed that the exercise gestures are classified with high accuracy in the proposed model.
In this study, CFRP and metal or nonmetal were bonded with adhesive and the fracture study on this material was carried out. CFRP at the upper side of specimen and metal or nonmetal were assigned at the lower side of specimen by using DCB specimen as the analysis condition. And it was desribed that the structural adhesive were bonded between both upper and lower sides. As this analysis result, the least equivalent stress was shown at the specimen bonded with aluminium. The maximum shear stress was shown to become lowest at the de-bonded CFRP specimen when titanium was used. In conclusion, it was shown that the deformation of specimen became lowest when titanium was used. On the basis of this study result, the esthetic sense can be shown as the fracture data of bonded interface using adhesive are grafted onto the real life.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.