• 제목/요약/키워드: the development of Instrument

검색결과 1,455건 처리시간 0.041초

한국형 골관절염영향측정척도(KAIMS) 도구개발 - 무릎 및 엉덩관절의 골관절염환자 중심 - (Development of Instrument for Korean Osteoarthritis Impact Measurement Scale (KAIMS) in Hip and Knee Osteoarthritis)

  • 이승주;김진섭
    • The Journal of Korean Physical Therapy
    • /
    • 제26권2호
    • /
    • pp.82-89
    • /
    • 2014
  • Purpose: This study was conducted in order to develop an instrument for the Korean Osteoarthritis Impact Measurement scale (KAIMS) in hip and knee osteoarthritis patients. Methods: A sample of 426 subjects was recruited in Ulsan metropolitan city (six hospitals and clinics) and Andong city (five hospitals and clinics) from June 2010 to May 2011. Item internal consistency and item discriminant validity were analyzed on the item-level, and floor (%) and ceiling (%) effect were analyzed on the scale-level. Exploratory factor analysis was performed for construction of items in the KAIMS instrument; confirmative factor analysis was also performed to test the fit of the model. Results: In 426 respondents, age was 64.3 years. The reliability for r coefficient 0.90 (mobility) and 0.89 (pain and stiffness) (Cronbach's alpha 0.95, 0.95 respectively) was high in the test-retest, and there was no significant difference in paired t-test (p>0.05). Item internal consistency (${\alpha}=0.92$, ${\alpha}=0.87$ respectively) was also high. It was constructed of two factors (mobility, pain and stiffness dimension) and nine items in explanatory factor analysis; results of confirmatory factor analysis also indicated that the dimensional structure model was fitted well in the test of model fit (${\chi}^2=83.83$, df=26, p=0.000; RMR=0.05; GFI=0.96; AGFI=0.83). Conclusion: In conclusion, the results of this study showed that the KAIMS that was developed was a reliable and valid instrument for measurement of osteoarthritis (OA) patients. We recommend further research for additional development of the instrument on OA in Korea.

광고를 통해 본 일제강점기 치과 장비 및 기구 광고에 관한 연구 (The study on advertisement of dental devices & instrument during Japanese colonized period)

  • 신재의
    • 대한치과의사협회지
    • /
    • 제48권12호
    • /
    • pp.893-918
    • /
    • 2010
  • This article is purposed of reviewing the development history of Japanese dental devices and instrument, and their related advertisement activities during the Japanese colonized period in Korea in early 20th century. Japanese dental devices and instrument were redesigned to accommodate their ergonomic shape above the simple imitation, and it implies the excessive desires brought them frustrations. The tragic earthquake on Sep. l, 1923, medical insurance law enforcement on Jan. 1, 1927, celebration of "Cavity prevention Day" started on Jun. 4, 1928, and the attack of Manchuria and China by Japan after 1931, all of these historical incidents become the preliminary requirement for the development of dental devices. On Nov. 1, 1937, Japanese government started to control dental materials, driving the campaigns for excluding foreign products and encourging the use of local products. In 1939, Nakajima dental manufacturers used this political and social atmosphere on their advertisement as saying "Our Nakajima's products have no compromise with the short raw materials, but only commitment to our quality". Since after 1940, the price and supply have been strongly under control, and the control group was appeared to manage all of supply and distribution of raw materials, regular price system, and specifications. At last, the Japanese national power were devastated in its production and distribution capacities, and get to the frustrated period. The main advertised dental devices and instruments in Korea during the Japanese colonized period were 1) dental chair, unit and cabinet, 2) dental x-ray, 3) compressors, 4) dental needles, 5) small instrument and carryon medical(emergency) kit, 6) oral hygiene and pyorrhea alveolaris, infrared rays, sunlight lamp, ultrashort wave treatment devices, 7)crown former, electric furnace, casting machine, articulator, electric lathe, and laboratory equipments, etc.

환경감수성 측정을 위한 검사 도구 개발과 이를 이용한 환경감수성 측정 - 중등학교 환경반을 대상으로 - (A Study on the Development and Measurement of Environmental Sensitivity among Middle School Environmental Class)

  • 이재붕;이두곤
    • 한국환경교육학회지:환경교육
    • /
    • 제19권3호
    • /
    • pp.138-149
    • /
    • 2006
  • The purpose of this study was to develop the environmental sensitivity(ES) measurement instrument and to apply for middle school students. The questionnaire was developed to evaluate ES. The developed questionnaire consists of 15 items in 5 categories. Each item of the instrument was developed through the conceptional analysis of the definition of ES. The 5 categories included natural environment, activity at natural environment, artificial environment, environmental pollution, environmental destruction. Data for this study were collected from 397 middle school students including 46 environmental class and 351 non-environmental class students. It was found that the developed instrument to measure ES was valid and reliable. Reliability coefficient, Cronbach $\alpha$ was 0.75. Using the developed instrument of ES, the ES was measured for the students of experimental group to which a inqury-based EE model was applied. The result was that the effect of ES of the students of the experimental group was not statistically significant. Futher research is needed related to the EE model based on the inquiry learning model and measurement of environmental sensitivity.

  • PDF

Development and Validation of an Instrument to Measure Nursing Information Literacy Competency

  • Jo, Meanjung;Ha, Yeongmi
    • 지역사회간호학회지
    • /
    • 제30권1호
    • /
    • pp.25-37
    • /
    • 2019
  • Purpose: The purpose of this study was to develop an instrument for measuring nursing information literacy competency, and then to examine the validity and reliability of the instrument. Methods: The developmental process of the instrument includes construction of a conceptual framework, generation of initial items, verification of content validity, preliminary study, extraction of final items, and psychometric testing. Its content validity was verified by three experts from nursing and nursing informatics. Its construct, convergent, and discriminant validity was examined in confirmatory factor analysis. Finally, its criterion validity was measured with Pearson's correlation. The tool's reliability was examined by Cronbach's ${\alpha}$. The participants include 382 nurses from four hospitals and one university hospital. Results: Twenty seven items in total were selected for the final scale, and the results of the confirmatory factor analysis were supported with acceptable model fit, which were named competency for identifying problem, potential sources for information, searching fine information, evaluating information, acquising and managing of information, using information ethically, and integrating new information. The convergent, discriminant and criterion validities were also supported. The Cronbach's ${\alpha}$ coefficient was .93. Conclusion: The instrument is valid and reliable to comprehensively assess nurses' information literacy competency, and to provide a basic direction for developing nursing information literacy program.

입원한 아동에게 제공되는 환자의 눈을 통한 간호의 질 측정도구 개발 (Development of an Instrument to Measure the Quality of Care through Patients' Eyes for Hospitalized Child)

  • 조해련;오진아;정덕유
    • Child Health Nursing Research
    • /
    • 제21권2호
    • /
    • pp.131-140
    • /
    • 2015
  • Purpose: The purpose of this study was to develop an instrument that evaluated QUality Of care Through patients' Eyes for hospitalized child (QUOTE-Child), and examine the validity and reliability. Methods: Preliminary items were reviewed through expert content validity and face validity. To test the validity and reliability of the instrument, the data were collected from 221 care givers of hospitalized children. Data were analyzed using exploratory factor analysis, Pearson correlation coefficient, Cronbach's alpha and Spearman-Brown coefficient. Results: Factor analysis yielded 19 items in four factors including 1) respect, 2) explanation, 3) kindness, and 4) skillfulness, with a cumulative explanatory variance of 70.68%. For criterion-related validity, a significant positive relationship was found between quality of care and pediatric family satisfaction. For internal consistency reliability, the Cronbach's ${\alpha}$ was .93 (importance) and .95 (performance) for the overall instrument. The half split reliabilities were .86, .95 (importance) and .92, .97 (performance). The Cronbach's ${\alpha}$ of 110 data was .92 (importance) and .94 (performance). Conclusion: Researchers and practitioners can use this instrument to systematically assess quality of care for hospitalized children and identify areas of support for hospitalized children and their family.

불임 여성의 불확실성 측정도구 개발 (Development of an Uncertainty Scale for Infertile Women)

  • 김미옥;김수
    • 여성건강간호학회지
    • /
    • 제16권4호
    • /
    • pp.370-380
    • /
    • 2010
  • Purpose: The purpose of this study was to develop an uncertainty scale for infertile women. Methods: The process included construction of a conceptual framework, generation of 12items, verification of content validity, selection of secondary items, verification of construct validity and extraction of final items. In order to verify the reliability and validity of the preliminary instrument, data were collected from 50 infertile women in an In Vitro Fertilization (IVF) clinic. Data were analyzed by item analysis, Varimax factor analysis and Cronbach's alpha. Results: There were 10 items in the final instrument categorized into 2 factors labeled as "personal (6 items)" and "relational (4 items)" The total variance explained was 73.36%. The instrument was shown to have good reliability with a Cronbach's alpha of .899. Conclusion: Validity and reliability of the scale were confirmed in this study showing its utility to measure uncertainty for infertile women. The instrument can help understand sterility and accurately measure uncertainty for infertile women. The instrument can also be used to evaluate nursing interventions designed for mitigating uncertainty for infertile women.

수술실 간호사의 직무 만족도 측정 도구 개발 연구 (Development and Validation of an Instrument to Measure the Job Satisfaction of Perioperative Nurses)

  • 윤계숙;박성애
    • 임상간호연구
    • /
    • 제15권1호
    • /
    • pp.93-106
    • /
    • 2009
  • Purpose: The purpose of this study was to develop a valid and reliable instrument to explore and measure job satisfaction as perceived by perioperative nurses, specifically from the perspective of contemporary perioperative nursing in Korea. Method: Items (69) were developed from the responses to two open-ended questions by 168 perioperative nurses in one teaching hospital; (a) reasons that make work enjoyable, (b) reasons that make work unpleasant. Finally 55 items were selected, excluding items with lower correlation with the total scale. The instrument was completed by 885 perioperative nurses from 89 different hospitals nationwide who were attending the annual conference of the Korean Association Operating Room Nurses (KAORN), yielding a response rate of 95.6%. Results: Ten factors were extracted by factor analysis, which explained 60.0% of the total variance; Reliability and internal consistency were established (Cronbach's alpha=.95). A smaller sample of 39 perioperative nurses completed the instrument on two occasions, with a 2-week interval between. Mean scores were computed and two sets of scores were analyzed by Weighted Kappa (W-Kappa=0.680, p=.029). Conclusion: This instrument is a concise, highly practical and flexible tool, which can be used for the perioperative nurse in a wide range of hospital settings.

원전 고온 1차수 환경에서 응력부식균열의 실시간 마이크로 스케일 관찰 방법 개발 (Development of Method for In-situ Micro-Scale Observation of Stress Corrosion Cracking in High-Temperature Primary Water Environment)

  • 신정호;이종연;김성우
    • Corrosion Science and Technology
    • /
    • 제22권4호
    • /
    • pp.265-272
    • /
    • 2023
  • The aim of this study was to develop a new in-situ observation method and instrument in micro-scale to investigate the mechanism of stress corrosion cracking (SCC) initiation of Ni-base alloys in a high temperature water environment of pressurized water reactors (PWRs). A laser confocal microscope (LCM), an autoclave with diamond window view port, and a slow strain-rate tester with primary water circulation loop system were components of the instrument. Diamond window, one of the core components of the instrument, was selected based on its optical, chemical, and mechanical properties. LCM was used to observe the specimen in micro-scale, considering the experimental condition of a high-temperature primary water environment. Using in-situ method and instrument, it is possible to observe oxidation and deformation of specimen surface in micro-scale through the diamond window in a high-temperature primary water in real-time. The in-situ method and instrument developed in this work can be utilized to investigate effects of various factors on SCC initiation in a high-temperature water environment.

환경 오염에 대한 중학생의 태도 평가 도구 개발 (Development of an instrument to assess middle school students' attitude toward environmental pollution)

  • 정은영;김영수
    • 한국과학교육학회지
    • /
    • 제13권2호
    • /
    • pp.272-281
    • /
    • 1993
  • The purpose of this study was. to develop a valid and reliable Likert-type scale to assess middle school students' attitude toward environmental pollution. The evaluation categories of this instrument were cognition and conaction levels. Initially, 42 statements (29 statements for cognition level and 13 statements for conaction level) were framed. This pilot instrument was administered to 1015 middle school students. To select valid and reliable statements, the 42 initial statements were analyzed by item mean, standard deviation, and response distribution. In addition, the emotional intensity: of each statement was judged. As a result, 22 final statements (14 statements for cognition level and 8 statements for conaction level) were developed. Cronbach alpha coefficient of the instrument was 0.76 with a range of item-total correlation from 0.229 to 0.488. Factor analysis was done to explore the potential constructs of this instrument. As a result, six factors were extracted. Those factors were identified as "Conaction to prevent environmental pollution", "Confrontation with the enterprise which causes environmental pollution", "Voluntary inclination to participate in the group which prevents environmental pollution", "Discussion on environmental pollution", "Environmental pollution and interests", and "Everyday sources of environmental pollution".

  • PDF

In-orbit performance prediction for Amon-Ra energy channel instrument

  • Seong, Se-Hyun;Hong, Jin-Suk;Ryu, Dong-Ok;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2011년도 한국우주과학회보 제20권1호
    • /
    • pp.30.2-30.2
    • /
    • 2011
  • In this report, we present in-orbit radiometric performance prediction for the Amon-Ra (Albedo Monitor and Radiometer) energy channel instrument. The Integrated Ray Tracing (IRT) computational technique uses the ray sets arriving at the Amon-Ra instrument aperture orbiting around the L1 halo orbit. Using this, the variation of flux arriving at the energy channel detector was obtained when the Amon-Ra instrument including the energy channel design observes the Sun and Earth alternately. The flux detectability was verified at the energy channel detector (LME-500-A, InfraTecTM). The detector time response and RMS signal voltage were then derived from the simulated flux variation results. The computation results demonstrate that the designed energy channel optical system satisfies the in-orbit detectability requirement. The technical details of energy channel instrument design, IRT model construction, radiative transfer simulation and output signal computation results are presented together with future development plan.

  • PDF