• Title/Summary/Keyword: the changes in size

Search Result 3,878, Processing Time 0.04 seconds

Glomus Tumor in Soft Tissue (연부 조직에 발생한 사구종)

  • Kim, Do-Yeon;Lee, Soo-Hyun;Kim, Min-Ju;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • Purpose: Glomus tumors are rare benign vascular tumors, usually located in the skin or soft tissue of extremities. Approximately 30-50% of glomus tumors occur in subungal area, but glomus tumors have been described in every location even where glomus bodies are not or rarely present. The purpose of this study was to identify clinical, histologic and MRI characteristics of soft tissue glomus tumor. Materials and Methods: Between 1993 and 2008, eight patients underwent surgery of soft tissue Glomus tumor at our institution. Exclusion criteria were patients with Glomus tumors in digits, stomach, trachea and glomus tympanicum. We analyzed medical records, interviews, physical examinations, MR findings and histolocial types retrospectively. Results: There were four men and four women. The mean age was fourty-seven years. The mean prevalence time was eight-point-nine years. In the classic triad of symptoms, all eight patients had pain and tenderness. Two patients complained of cold sensitivity. Two showed skin color changes. After surgery, two showed symptom improvement (VAS $9^{\circ}{\rightarrow}8$, $8^{\circ}{\rightarrow}5$) and?six showed complete disappearance of symptoms. Slightly symptom improvemented (VAS $9^{\circ}{\rightarrow}8$) one had additional surgery two times after first surgery due to relapse/remaining Glomus tumor. The mean size was 13.9 mm. In histology, six were 'solid glomus tumor', one was a mixture of 'solid glomus tumor' and 'lomangioma' and one was 'malignant glomus tumor'. MR findings showed isointense signal on T1 image, high signal on T2 image and strong enhancement on the Gadolinium enhanced image. Conclusion: Glomus tumor has low recurrence rate and malignant change, rapid diagnosis and surgical excision is critical in treatment to prevent unnecessary pain of patient.

  • PDF

Fermentation Properties and Increased Health Functionality of Kimchi by Kimchi Lactic Acid Bacteria Starters (김치 유산균 Starter를 이용한 김치의 발효 특성 및 기능성 증진 효과)

  • Bong, Yeon-Ju;Jeong, Ji-Kang;Park, Kun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1717-1726
    • /
    • 2013
  • Fermentation characteristics and health functionalities of kimchi by inoculating kimchi lactic acid bacteria (LAB) starters were studied. We manufactured single LAB starter kimchi (Lactobacillus plantarum pnuK, Lactobacillus plantarum 3099K, Leuconostoc mesenteroides pnuK), mixed LAB starter kimchi (Lb. plantarum pnu/Leu. mesenteroides pnuK, Lb. plantarum 3099/Leu. mesenteroides pnuK) with inoculum size of $10^6$ CFU/g, as well as naturally fermented kimchi (NK), and fermented them for 6 days at $15^{\circ}C$. The pH and acidity of the early phase of fermentation were not different, but kimchi with the starters showed rapid changes in the pH and acidity from 2 days of fermentation. As the fermentation progressed, the level of total aerobic bacteria and Lactobacillus sp. increased similarly with or without Lb. plantarum (LP) inoculation. However, the level of Leuconostoc sp. was high in kimchi inoculated with Leuconostoc sp. starter. In the sensory evaluation test, kimchi with starters received higher overall acceptability scores than those of NK; mixed starter added kimchi earned the highest score. In DPPH and hydroxyl radical scavenging activity, kimchi with the starters exhibited higher activity than that of NK. In the MTT assay of HCT-116 and HT-29 human colon cancer cells, NK showed inhibition rates of 63.4 and 51.9%, but LPpnuK achieved 77.1 and 68.8%, respectively. This study showed that inoculating starters in kimchi increased in vitro antioxidant and anticancer activities, and single starter (LP) added kimchi revealed higher functionality than the kimchi with mixed starter. Kimchis with the starters effectively up-regulated the gene expressions of the pro-apoptotic gene of Bax, but down-regulated Bcl-2. They promoted expressions of p53 and p21, and suppressed expressions of inflammation-related genes, iNOS and COX-2, compared with NK. Taken together, it is expected that using starters may help manufacture kimchi with improved sensory quality and health functionality.

Matching Points Filtering Applied Panorama Image Processing Using SURF and RANSAC Algorithm (SURF와 RANSAC 알고리즘을 이용한 대응점 필터링 적용 파노라마 이미지 처리)

  • Kim, Jeongho;Kim, Daewon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.144-159
    • /
    • 2014
  • Techniques for making a single panoramic image using multiple pictures are widely studied in many areas such as computer vision, computer graphics, etc. The panorama image can be applied to various fields like virtual reality, robot vision areas which require wide-angled shots as an useful way to overcome the limitations such as picture-angle, resolutions, and internal informations of an image taken from a single camera. It is so much meaningful in a point that a panoramic image usually provides better immersion feeling than a plain image. Although there are many ways to build a panoramic image, most of them are using the way of extracting feature points and matching points of each images for making a single panoramic image. In addition, those methods use the RANSAC(RANdom SAmple Consensus) algorithm with matching points and the Homography matrix to transform the image. The SURF(Speeded Up Robust Features) algorithm which is used in this paper to extract featuring points uses an image's black and white informations and local spatial informations. The SURF is widely being used since it is very much robust at detecting image's size, view-point changes, and additionally, faster than the SIFT(Scale Invariant Features Transform) algorithm. The SURF has a shortcoming of making an error which results in decreasing the RANSAC algorithm's performance speed when extracting image's feature points. As a result, this may increase the CPU usage occupation rate. The error of detecting matching points may role as a critical reason for disqualifying panoramic image's accuracy and lucidity. In this paper, in order to minimize errors of extracting matching points, we used $3{\times}3$ region's RGB pixel values around the matching points' coordinates to perform intermediate filtering process for removing wrong matching points. We have also presented analysis and evaluation results relating to enhanced working speed for producing a panorama image, CPU usage rate, extracted matching points' decreasing rate and accuracy.

Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.

Time-Lapse Crosswell Seismic Study to Evaluate the Underground Cavity Filling (지하공동 충전효과 평가를 위한 시차 공대공 탄성파 토모그래피 연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • Time-lapse crosswell seismic data, recorded before and after the cavity filling, showed that the filling increased the velocity at a known cavity zone in an old mine site in Inchon area. The seismic response depicted on the tomogram and in conjunction with the geologic data from drillings imply that the size of the cavity may be either small or filled by debris. In this study, I attempted to evaluate the filling effect by analyzing velocity measured from the time-lapse tomograms. The data acquired by a downhole airgun and 24-channel hydrophone system revealed that there exists measurable amounts of source statics. I presented a methodology to estimate the source statics. The procedure for this method is: 1) examine the source firing-time for each source, and remove the effect of irregular firing time, and 2) estimate the residual statics caused by inaccurate source positioning. This proposed multi-step inversion may reduce high frequency numerical noise and enhance the resolution at the zone of interest. The multi-step inversion with different starting models successfully shows the subtle velocity changes at the small cavity zone. The inversion procedure is: 1) conduct an inversion using regular sized cells, and generate an image of gross velocity structure by applying a 2-D median filter on the resulting tomogram, and 2) construct the starting velocity model by modifying the final velocity model from the first phase. The model was modified so that the zone of interest consists of small-sized grids. The final velocity model developed from the baseline survey was as a starting velocity model on the monitor inversion. Since we expected a velocity change only in the cavity zone, in the monitor inversion, we can significantly reduce the number of model parameters by fixing the model out-side the cavity zone equal to the baseline model.

  • PDF

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

A stratified random sampling design for paddy fields: Optimized stratification and sample allocation for effective spatial modeling and mapping of the impact of climate changes on agricultural system in Korea (농지 공간격자 자료의 층화랜덤샘플링: 농업시스템 기후변화 영향 공간모델링을 위한 국내 농지 최적 층화 및 샘플 수 최적화 연구)

  • Minyoung Lee;Yongeun Kim;Jinsol Hong;Kijong Cho
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.4
    • /
    • pp.526-535
    • /
    • 2021
  • Spatial sampling design plays an important role in GIS-based modeling studies because it increases modeling efficiency while reducing the cost of sampling. In the field of agricultural systems, research demand for high-resolution spatial databased modeling to predict and evaluate climate change impacts is growing rapidly. Accordingly, the need and importance of spatial sampling design are increasing. The purpose of this study was to design spatial sampling of paddy fields (11,386 grids with 1 km spatial resolution) in Korea for use in agricultural spatial modeling. A stratified random sampling design was developed and applied in 2030s, 2050s, and 2080s under two RCP scenarios of 4.5 and 8.5. Twenty-five weather and four soil characteristics were used as stratification variables. Stratification and sample allocation were optimized to ensure minimum sample size under given precision constraints for 16 target variables such as crop yield, greenhouse gas emission, and pest distribution. Precision and accuracy of the sampling were evaluated through sampling simulations based on coefficient of variation (CV) and relative bias, respectively. As a result, the paddy field could be optimized in the range of 5 to 21 strata and 46 to 69 samples. Evaluation results showed that target variables were within precision constraints (CV<0.05 except for crop yield) with low bias values (below 3%). These results can contribute to reducing sampling cost and computation time while having high predictive power. It is expected to be widely used as a representative sample grid in various agriculture spatial modeling studies.

Salty-taste Activation of Human Brain Disclosed by Gustatory fMRI Study (뇌기능 자기공명영상 장치를 이용한 짠맛 자극에 따른 인간 뇌의 반응에 대한 기초 연구)

  • Kim S.H.;Choi K.S.;Lee H.Y.;Shin W.J.;Eun C.K.;Mun C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 2005
  • Purpose : The purpose of this study is to observe the blood oxygen level dependent (BOLD) contrast changes due to the reaction of human brain at a gustatory sense in response to a salty-taste stimulation. Materials and Methods : Twelve healthy, non-smoking, right-handed male subjects (mean age: 25.6, range: 23-28 years) participated in this salty-taste stimulus functional magnetic resonance (fMRI) study. MRI scans were performed with 1.57 GE Signa, using a multi-slice GE-EPI sequence according to a blood-oxy-gen-level dependent (BOLD) experiment paradigm. Scan parameters included matrix size $128\times128$, FOV 250 mm, TR 5000 msec, TE 60 msec, TH/GAP 5/2 mm. Sequential data acquisitions were carried out for 42 measurements with a repetition time of 5 sec for each taste-stimulus experiments. Analysis of fMRI data was carried out using SPM99 implemented in Matlab. NaCl solution $(3\%)$ was used as a salty stimulus. The task paradigm consisted of alternating rest-stimulus cycles (30-second rest, 15-second stimulus) for 210 seconds. During the stimulus period, NaCl-solution was presented to the subject's mouth through plastic tubes as a bolus of delivered every 5 sec using -processor controlled auto-syringe pump. Results : Insula, frontal opercular taste cortex, amygdala and orbitofrontal cortex (OFC) were activated by a salty-taste stimulation $(NaCl,\;3\%)$ in the fMRI experiments. And dosolateral prefrontal cortex (DLPFC) was also significantly responded to salty-taste stimuli. Activation areas of the right side hemisphere were more superior to the left side hemisphere. Conclusion : The results of this study well correspond to the fact that both insula, amygdala, OFC, DLPFC areas are established as taste cortical areas by neuronal recordings in primates. Authors found that laboratory-developed auto-syringe pump is suitable for gustatory fMRI study. Further research in this field will accelerate to inquire into the mechanism of higher order gustatory process.

  • PDF

Studies on the Processing of Powdered Katsuobushi and Its Flavor Constituents 1. Processing Conditions of Powdered Katsuobushi and Its Taste Compounds (분말가쓰오부시의 제조 및 풍미성분에 관한 연구 1. 분미가쓰오부시의 가공조건 및 정미성분)

  • OH Kwang-Soo;LEE Eung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 1988
  • This study was carried out to develop the powdered Katsuobushi (a kind of boiled, smoked, and dried fish product which is used for seasoning soup as it is.) using skipjack as a natural flavoring substance. The processing conditions of the powdered Katsuobushi and the changes of taste compounds during processing of the products were examined. In preparation of the powdered Katsuobushl, frozen skipjack was thawed, beheaded, gutted, filleted and then sliced to 1cm of thickness. The silted meats were boiled in skipjack extract for 20 minutes, and then it was smoked for, 3 times to $10\~12\%$ moisture content at $80^{\circ}C$ for 8 hours. The smoked - dried meats were followed to be 50 mesh of particle size. The effect of slicing and boiling in skipjack meat extract on enhancing flavor and on preventing lipid oxidation of product during processing were observed. The moisture content and crude lipid content of the powdered Katsuobushi was in the range of 11 to $12\%$ and 4.3 to $4.8\%$, respectively. The taste compounds of the product were nucleotides and their related compounds, 1135.8mg/100g ; free amino acid and related compounds, 2210.2mg/100g ; non-volatile organic acids, 1148.0mg/100g ; and total creatinine. 592.1mg/100g on dry basis, and small amount of betaine and TMAO. The major elements of mineral in the product were found to be K, Mg, Na, and Ca. The content of IMP was 542.0mg/100g, and major free amino acids were found to be histidine, anserine, taurine, carnosine and alanine of which occupied to $83.6\%$ of total free amino acids. In non -volatile organic acids, major ones were lactic acid, succinic acid, pyroglutamic acid and $\alpha-ketoglutaric$ acid. From the results of the chemical experiments and sensory evaluation, we may conclude that the flavor of the product from present experiment is more desirable than that of conventional products although the processing time used were much shortened than that of conventional method, and it can be commercialized as a seasoning powder.

  • PDF

Ten Years Experiences of ATS Mechanical Valve (ATS 기계 판막의 10년 임상경험)

  • Yi, Gi-Jong;Bae, Mi-Kyung;Lim, Sang-Hyun;Yoo, Kyung-Jong;Chang, Byung-Chul;Hong, You-Sun
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.891-899
    • /
    • 2006
  • Background: This study is to evaluate the safety of ATS valve by examining the clinical results of ten-years experience. Material and Method: From July 1995 to March 2005, we reviewed 305 patients with ATS valve implantation. Mean age was $49.8{\pm}11.7$ years and 140(45.6%) males were included. Etiologies were rheumatic diseases in 207 cases(67.4%), degenerative changes in 57 cases(18.6%), valve dysfunction in 23 cases(7.5%) and infective endocarditis in 14 cases(4.6%). AVR was performed in 72 patients(23.5%), MVR in 156 patients (50.8%), DVR(AVR+MVR) in 63 patients(20.5%) and TVR in 16 patients(5.2%). Result: There were 9 operative mortalities(2.9%). Follow up period was $56.5{\pm}34.0(0{\sim}115)$ months and 96.4% patients were followed up with 9 late deaths. Five and ten years survival rates were $94.9{\pm}1.3%,\;91.2{\pm}2.3%$ using Kaplan-Meier's methods. Valve related event free survival rates in 5 and 10 years were $90.8{\pm}2.0%$ and $86.9{\pm}3.2%$. There were 16 anticoagulation-related hemorrhages, 6 thromboembolisms, 3 prosthetic valve endocarditis and 1 paravalvular leakage. NYHA class improved after operation(p<0.05). Postoperative echocardiography showed significant decrease in LA size, LVEDD and IVESD(p<0.01). Patients with 19 and 21 mm valve showed significantly higher transvalvular pressure gradient in aortic position(p<0.001, p<0.001). Conclusion: ATS valve showed good hemodynamic results with few valve related complications and thus can be used with acceptable risk.