• Title/Summary/Keyword: the Number of Rooms

Search Result 315, Processing Time 0.027 seconds

A Study on the Dissatisfaction Evaluation of Rental Apartment Residents and Recognition of Neighborhoods (영구임대아파트 거주민의 불만도와 인근주민의 인식에 대한 연구)

  • Kim, Min-Hee;Choi, Jung-Min
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.355-358
    • /
    • 2005
  • This study investigates both the dissatisfaction evaluation of residents in Kangseo Permanant Rental Housing(PRH) complex managed by SH corporation and their neighborhood's recognition on the PRH complex in terms of questionnaires divided by two groups. The result shows that the residents in PRH complex are especially dissatisfied with lining space and number of rooms, parking capacity, outmoded building, and incidence of crime.

  • PDF

A Study on the Structure of Combined Architecture of Dang and Sil in the Early Joseon Dynasty -Focusing on the Rectangular Plan and the Gable Roof Meeting at Right Angle- (조선전기 당(堂)·실(室) 결합 건축의 가구특성 분석 -방형 평면의 맞배직교형 지붕 가구를 중심으로-)

  • Kim, Bue-Dyel;Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.26 no.2
    • /
    • pp.31-42
    • /
    • 2017
  • This study investigates how the spatial recognition structure is emerging through the case of rectangular plan combined with a combination of Dang-Sil(堂室) and Gong(工) shape roof, and identifies a type of architecture in the early Joseon Dynasty that has never been revealed. The conclusion of this study is as follows. First, the Dang and the Sil are connected to each other, but the architectural elements such as pillars, frame, and windows are distinguished and appear as separate buildings. Second, the distinction between Dang and Sil is evident by the difference in the number of ridges and the shape of the roof. In addition, the roof and roof framework of the independent rooms and the rooms were common in the right angled architecture where the direction and the expandability of each structure were maintained. Third, the construction of the Dang-Sil combined structure, in which two or more structure frameworks were combined with the rectangular combined flat roof structure, gradually changed into a single structure with a single ridge. Fourth, this change means that people of the early Joseon Dynasty recognized the Dang and Sil as separate architecture, but the strict sense of spatial separation has disappeared over time.

A Study on the Effective Utilization of Extra Classrooms of a School (저출산에 의한 학생수 감소에 따른 여유교실 활용방안 모색)

  • Lee, Baik- Ryul
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.53-65
    • /
    • 2007
  • Our society is changing into the society of knowledge and information since the advent of 21st century. This may require that schooling need to have a new paradigm. Korea has already entered into the aging society with the help of various population control policies such as birth control from 1960s, and is expecting to go into the so called ultra- aging society. Elementary and middle schools have been facing the rapid decrease in the number of students since the mid-1980s, which high schools are now confronting with. The present study investigates how to effectively utilize extra classrooms at schools. The present study offers eight basic directions that may help establish the utilization planning of extra classrooms. One direction is offering an appropriate space utilization environment, another is to present a plan for having special classrooms. Others are having multi-purpose classrooms, management on the unified rooms for library and audio-visual teaching, securing facilities rooms for the school staff. And others are the planning of the diversion of living space for improving sanitation and the provision of meals, the necessity of the extension or rebuilding of school buildings for other uses according to school development schemes, the utilization planning for community residents to which each school belong.

  • PDF

A Study on the Characteristics of Jeju Recreational Pension (제주도 휴양펜션시설의 건축실태에 관한 연구)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.135-140
    • /
    • 2004
  • The purpose of this research is to investigate the characteristics of Jeju recreational pension. This research is carried out by on site inspection and the survey on management of the recreation facilities. A target of research is sixteen facilities of recreation pension in Jeju-do. Recreational pension was created by Jeju Free International City of special law in 2000. Jeju Recreational pension has characteristics as follows : The land area of that is $1300m^{2}{\sim}6300m^{2}$, the number of guest rooms are 10, and the area of guest rooms are $29m^{2}{\sim}100m^{2}$. Especially most of them are in Namjeju-gun. Also, they mostly have R.C. structure, and materials of exterior are artificiality stone. The color of an outer walls are mostly white and light-beige and that of the roofs are mainly dark-brown. On plot plan, it has 4type of prototype; type of outbuilding, arranging in a row, corridor, hall and composition of three types with public area. The outside facilities are equipped by handy golf courses and outdoor barbecue cooking sites. Unfortunately, most of pensions don't reflect the characteristics of architecture factors in Jeju.

  • PDF

Effects of Infection Control Education for Families of VRE Patients (VRE 환자의 보호자를 위한 감염관리 교육의 효과)

  • Seo, Jung;Kang, Ji-Yeon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.19 no.2
    • /
    • pp.212-222
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of infection control education for families of patients infected with vancomycin resistant enterococcus (VRE). Method: Forty family members of VRE patients were chosen from a university hospital and assigned to the experimental or control group. The experimental group was provided infection control education that consisted of one-on-one instruction using an information booklet, hand-washing video, and demonstration of hand washing practice. Dependent variables were self-reported knowledge and performance of VRE infection control measures, and the number of hand washings when entering and leaving patients' rooms. Results: Knowledge and performance scores were significantly higher for the experimental group compared to the control group. The experimental group washed their hands significantly more often when entering and leaving patients' rooms than the control group. Conclusion: Infection control education for family members of VRE patients was effective in improving knowledge and performance of infection control measures as well as improving the practice of hand washing. Further investigation is needed on the effects of infection control education for families on the actual VRE colonization and/or infection rate.

Changes in Use and Functions of Second Doors in Detached Houses of Rural Area (농촌 단독주택 부출입문의 기능 및 이용변화에 대한 사례조사)

  • Byun, Kyeonghwa;Lee, Yunjeong;Kwon, Young-Gyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.4
    • /
    • pp.57-65
    • /
    • 2015
  • In contrast to apartments, detached houses offer the possibility of more than one entrance connecting interior and exterior spaces. This study examines the location, function, and use of second doors in detached houses in rural areas. The study employs survey and interviews conducted in 2015, focusing on 18 detached houses among 40 houses previously surveyed in 1995. In 1995, 21 second doors were found, while in 2015, 19 were found. The study led to the following conclusions. First, most houses did have second doors installed by 1995 or 2015. Second doors tended to be installed in kitchen and utility rooms. The function of second doors was most closely connected to the kitchen because utility rooms were placed adjacent to kitchens. Secondly, changes in the use and number of second doors were changes in family life cycle and composition, the need for new equipment facilities, the use of new architectural materials, and the installation of new second doors for extension of space. Finally, exterior spaces accessed by second doors tend to be a meeting of semi-interior or semi-exterior space and exterior space only. Those spaces tended to be designed for kitchen fixtures or to support kitchen activities.

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods (추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석)

  • Han, Hwa-Taik;Cho, Seok-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

Factors Influencing on Fatigue in Operating Room Nurses (수술실 간호사의 피로 예측요인)

  • Lee, Eun-Seon;Kim, In-Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.21 no.3
    • /
    • pp.229-238
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the fatigue of operating room nurses and examine factors contributing to their fatigue. Methods: The subjects of this study were 115 nurses who worked in operating rooms of three hospitals. Data were collected from September 15, 2009 to September 30, 2009. Fatigue and job stress were measured by using the Symptom's Fatigue Scale and the job stress measurement tools in operating room nurses. Results: The mean score of fatigue level was $3.10{\pm}0.61$. We analyzed fatigue according to characteristics of subjects and found that there were significant differences in marital status, number of children and sleeping hours in general characteristics. Career, daily participation hours in the surgery relating to job related characteristics. Significant positive correlations were found between job stress and fatigue(r=.233, p= .012). Three significant variables influencing fatigue of operation rooms nurses were job stress, daily participation hours in the surgery, and sleeping hours (Adj. $R^2$=0.284, F=4.773, p<.001). Conclusion: An integrative care program that takes job stress, daily participation hours in the surgery and sleeping hours into consideration is essential to reduce fatigue in operating room nurses.

A Study on Tracer Gas Methodology to Measure Interzonal Airflow Rates (실간환기량 측정을 위한 추적가스 실험방법론에 관한 연구)

  • Han, Hwa-Taik;Cho, Seok-Hyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.606-612
    • /
    • 2009
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.