KOLAS 교정기관 간 측정 동등성 확립을 위한 상대습도 변환기 숙련도 시험 (Relative Humidity Transducer Proficiency Test for KOLAS Humidity Calibration Laboratories)

  • 이상욱;이영석;최병일
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.447-454
    • /
    • 2023
  • The Korea Laboratory Accreditation Scheme (KOLAS) operates accreditation programs for ensuring measurement traceability with the International System (SI) of Units - the highest calibration standard that measurements can be tested against. As of September 2023, there are 70 KOLAS-accredited laboratories in the Republic of Korea that specialize in humidity calibration. Among them, 32 KOLAS laboratories, along with one laboratory not affiliated with KOLAS, participated in the proficiency test (PM 2023-11) for relative humidity transducers in 2023. This proficiency test was conducted within a relative humidity range of 20-90% at a temperature of approximately 20 ℃, taking into consideration the calibration and measurement capability (CMC) of the participating laboratories. The primary objective of the proficiency test was to establish the measurement equivalence between each participating laboratory and the reference laboratory, by calculating the number of equivalence (En). When |En| was less than 1, the measurements from the participating and reference laboratory were equivalent. Out of the 33 participating laboratories, 32 successfully met this criterion and passed the proficiency test.

Purity assignment of 17α-hydroxyprogesterone by mass balance method to establish traceability in measurement

  • Lee, Hwa Shim;Park, Su Jin
    • 분석과학
    • /
    • 제32권6호
    • /
    • pp.225-232
    • /
    • 2019
  • Traceability establishment in chemical measurements is a like a linkage established through an unbroken chain from the measured results to the international system (SI) of units. The primary process for traceability establishment is the purity assignment of a target material to be measured. In this study, we studied the purity assignment of 17α-hydroxyprogesterone (17-OHP). The presence of 17-OHP is indicative of congenital adrenal hyperplasia (CAH) and it builds up due to the deficiency of 21-hydroxylase and 11β-hydroxylase enzyme in the human blood. The purity assignment of 17-OHP was performed by the mass balance method, in which the impurities are categorized into four classes: total related structural impurities, water, residual organic solvents, and nonvolatiles/inorganics. The total related structural impurities were characterized by HPLC-UV; water content was determined by Karl-Fisher coulometer; and the total residual solvents and nonvolatiles/inorganics were determined by TGA. The purity of 17-OHP from a commercial manufacturer was calculated as 993.30 mg/g, and the expanded uncertainty was 0.58 mg/g. The proposed method was validated by uncertainty evaluation and comparing with the actual value of purity.

유해대기오염물질 중 14종의 휘발성유기화합물 1차 표준가스개발 (1 μmol/mol 수준) (Development of Primary Standard Gas Mixtures of Fourteen Volatile Organic Compounds in Hazardous Air Pollutants for Accurate Ambient Measurements in Korea (at 1 μmol/mol Levels))

  • 강지환;김용두;김미언;이진홍;이상일
    • 한국대기환경학회지
    • /
    • 제34권2호
    • /
    • pp.331-341
    • /
    • 2018
  • Hazardous air pollutants(HAPs) in the atmosphere are regulated as major air pollutants in Korea by the Air Pollution Control Act. In order to manage and control HAPs, accurate standards, which are traceable to the International System of Units(SI), are required. In this study, primary standard gas mixtures(PSMs) of volatile organic compounds(VOCs) which are specified as HAPs were developed at $1{\mu}mol/mol$ levels. The selected fourteen VOCs include Benzene, Toluene, Ethylbenzene, m-Xylene, Styrene, o-Xylene, Chloroform, 1,1,2-Trichloroethane, Trichloroethylene, Tetrachloroethylene, 1,1-Dichloroethane, Carbon tetrachloride, 1,3-Butadiene, and Dichloromethane. The HAPs PSMs were gravimetrically prepared in aluminum cylinders and their consistency was verified within the relative expanded uncertainty of 0.71% (k=2). Potential adsorption loss onto the internal surface of cylinders was estimated by cylinder-to-cylinder division method. No adsorption loss was observed within the uncerainty of 0.53%. The long-term stability of the HAPs PSMs was evaluated comparing with freshly prepared HAPs PSMs. The HAPs PSMs were stable for one year within the uncertainty of 0.38%. The final uncertainty of the PSMs was determined by combining the preparation uncertainty, verification uncertainty, and stability uncertainty. Finally, traceable and stable HAPs PSMs at $1{\mu}mol/mol$ levels were developed with the uncertainty of less than 0.76% in high-pressure aluminum cylinders.

가르칠 지식으로서 무게에 대한 분석: 교수학적 변환 이론을 중심으로 (Weight as Knowledge to be taught according to Didactic Transposition Theory)

  • 최지선
    • 한국수학교육학회지시리즈C:초등수학교육
    • /
    • 제25권4호
    • /
    • pp.377-394
    • /
    • 2022
  • 초등학교 3~4학년군에서 무게를 지도하는 방식이 2015 개정 수학과 교육과정과 2015 개정 과학과 교육과정에서 상이하여, 초등학교 교사들과 학생들의 혼란이 야기된다는 비판이 제기되었다. 이에 본 연구는 사회적으로 사용된 지식이 가르쳐질 지식으로 교수학적 변환되는 과정에서 고려해야 할 사회적 인정성을 확인하고, 교수학적 의도에 따라 다르게 변환된 정도를 비교·분석하고자 하였다. 이를 위해 일상적 의미에서의 무게의 의미, 국제단위계에 따른 무게의 정의, 수학과 교육과정과 교과서에 구현된 무게, 과학과 교육과정과 교과서에 구현된 무게를 분석하였다. 이러한 분석을 통해서 가르칠 지식으로서의 무게를 어떻게 정의하고 가르칠 것인가에 관한 교수학적 관점을 도출하였다.

$^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰 (Packing effects on the intracavitary radiation therapy of the utaine lervix cancer)

  • 조정근;이두현;시창근;최윤경;김태윤
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.73-77
    • /
    • 2004
  • 연구목적 : 자궁경부암 환자에게 시행되는 고선량을 강내조사의 경우 선원이 병소 근처에 위치함으로써 주변의 중요 장기에 최소의 선량이 투여될 수 있도록 치료계획이 가능하다. 하지만 해부학적 위치 상 방광과 직장이 병소와 근접하여, 선량을 최소화하고자 Packing을 시행한다. 본 연구에서는 실제 Packing의 효과를 알아보고자 모의치료시 packing을 시행한 것과 packing을 제거한 후의 사진을 얻어 ICRU(International Commission on Radiation Units) 38에 report 된 방광과 직장의 point dose를 비교하였다. 대상 및 방법 : Packing 전, 후의 방광과 직장의 선량변화를 알아보기 위하여 packing을 시행한 후 AP, LAT film을 촬영하고, 또한 동일한 상태에서 packing을 제거한 후 AP, LAT film을 촬영하여 확인하고자 하는 방광과 직장의 reference point를 각각 표시하고 이를 치료계획장치(PLATO BPS v13.7)에 입력한 후 ICRU 38 report에서 권고한대로 A point에 $100\%$ 선량을 prescription하는 치료계획을 시행하였다. 하지만 rectum의 경우 ICRU에서 제시한 point가 rectum point를 정확히 대변하지 못하는 이유로 maximum point를 찾아 비교하였다. 측정한 값들을 윌콕슨의 부호검정(SAS, 통계분석처리프로그램)을 통하여 packing 효과의 유의성에 대하여 분석하였다. 결 과 : packing을 시행하지 않은 상태에서의 방광과 직장 선량은 각각 $80.1{\pm}16.8(\%),\;82.7{\pm}16.3(\%)$이었고, packing을 시행한 경우 각각 $63.0{\pm}16.3(\%),\;67.6{\pm}16.3(\%)$로, 방광선량의 경우 평균선량이 $17.2{\pm}4.0(\%)$ 감소한 것으로 나타났으며, 직장선량의 경우 평균선량이 $15.1{\pm}9.9(\%)$ 감소한 것으로 나타났다. 이를 윌콕슨의 부호검정을 통하여 분석한 결과 방광과 직장 모두 검정통계량 값이 33으로 매우 크고 p 값이 0.001로서 매우 유의한 차이를 보이고 있다. 다시 말해서 $99\%$의 유의수준에서도 모평균(packing 여부에 따른 방광과 직장선량의 평균의 차이가 정량적 수치로 나타나 packing의 효과를 알 수 있다)의 차이가 뚜렷하다고 볼 수 있다. 결 론 : 자궁경부암에 있어 강내치료는 외부치료와 더불어 반드시 시행하여야 하는 치료로 인식되어 있다. 그 이유는 주변 주요장기인 방광과 직장을 피해 원발 병소에만 방사선량을 현저히 많은 양을 부여함으로써 높은 치료효과를 볼 수 있기 때문이다. 하지만 서른에서 언급하였듯이 해부학적으로 주요장기가 너무 인접하여 있기 때문에 이들을 인위적으로 분리시키지 않으면 안된다. 이러한 목적을 달성하기 위하여 packing을 사용하는데, 본 실험을 통하여 자궁경부암 강내치료시 사용하는 packing 방법의 효과가 매우 탁월함을 알 수 있었고 적극적인 packing을 통해 방사선치료시 가장 우려되는 주변의 정상조직의 부작용이 감소할 수 있도록 최선의 노력을 하여야 할 것으로 사료된다.

  • PDF