• Title/Summary/Keyword: tetralogy of fallot

Search Result 177, Processing Time 0.023 seconds

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.50 no.2
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

Investigation of right ventricle function in patients with tetralogy of Fallot after total correction using cardiac magnetic resonance imaging (심장 자기공명영상을 이용한 팔로사징 완전 교정술 후 우심실 기능에 대한 연구)

  • Jang, Woo Sung;Choi, Hee Joung;Lee, Jong-Min;Kim, Jae Bum;Kim, Jae Hyun;Jang, Jae Seok
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.238-241
    • /
    • 2017
  • Background: We investigated the difference in right ventricle (RV) volume and ejection fraction (EF) according to the pulmonary valve (PV) annular extension technique during Tetralogy of Fallot (TOF) total correction. Methods: We divided patients who underwent the procedure from 1993 to 2003 into two groups according to PV extension technique (group I: PV annular extension, group II: no PV annular extension) during TOF total correction. We then analyzed the three segmental (RV inlet, trabecular and outlet) and whole RV volume and EF by cardiac magnetic resonance imaging (MRI). Results: Fourteen patients were included in this study (group I: 10 patients, group II: four patients; male: nine patients, female: five patients). Cardiac MRI was conducted after a 16.1 years TOF total correction follow-up period. There was no statistical difference in RV segmental volume index or EF between groups (all p>0.05). Moreover, the total RV volume index and EF did not differ significantly between groups (all p>0.05). Conclusion: The RV volume and EF of the PV annular extension group did not differ from that of the PV annular extension group. Thus, PV annular preservation technique did not show the surgical advantage compared to PV annular extension technique in this study.

Surgical Results of Monocusp Implantation with Transannular Patch Angioplasty in Tetralogy of Fallot Repair

  • Jang, Woo Sung;Cho, Joon Yong;Lee, Jong Uk;Lee, Youngok
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Monocusp reconstruction with a transannular patch (TAP) results in early improvement because it relieves residual volume hypertension during the immediate postoperative period. However, few reports have assessed the long-term surgical outcomes of this procedure. The purpose of the present study was to evaluate the mid-term surgical outcomes of tetralogy of Fallot (TOF) repair using monocusp reconstruction with a TAP. Methods: Between March 2000 and March 2009, 36 patients with a TOF received a TAP. A TAP with monocusp reconstruction (group I) was used in 25 patients and a TAP without monocusp reconstruction (group II) was used in 11 patients. We evaluated hemodynamic parameters using echocardiography during the follow-up period in both groups. Results: At the most recent follow-up echocardiography (mean follow-up, 8.2 years), the mean pulmonary valve velocities of the patients in group I and group II were $2.1{\pm}1.0m/sec$ and $0.9{\pm}0.9m/sec$, respectively (p=0.001). Although the incidence of grade 3-4 pulmonary regurgitation (PR) was not significantly different between the two groups (group I: 16 patients, 64.0%; group II: 7 patients, 70.0%; p=0.735) during the follow-up period, the interval between the treatment and the incidence of PR aggravation was longer in group I than in group II (group I: $6.5{\pm}3.4years$; group II: $3.8{\pm}2.2years$; p=0.037). Conclusion: Monocusp reconstruction with a TAP prolonged the interval between the initial treatment and grade 3-4 PR aggravation. Patients who received a TAP with monocusp reconstruction to repair TOF were not to progress to pulmonary stenosis during the follow-up period as those who received a TAP without monocusp reconstruction.

The change of QRS duration after pulmonary valve replacement in patients with repaired tetralogy of Fallot and pulmonary regurgitation

  • Yun, Yuni;Kim, Yeo Hyang;Kwon, Jung Eun
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.11
    • /
    • pp.362-365
    • /
    • 2018
  • Purpose: This study aimed to analyze changes in QRS duration and cardiothoracic ratio (CTR) following pulmonary valve replacement (PVR) in patients with tetralogy of Fallot (TOF). Methods: Children and adolescents who had previously undergone total repair for TOF (n=67; median age, 16 years) who required elective PVR for pulmonary regurgitation and/or right ventricular out tract obstruction were included in this study. The QRS duration and CTR were measured pre- and postoperatively and postoperative changes were evaluated. Results: Following PVR, the CTR significantly decreased (pre-PVR $57.2%{\pm}6.2%$, post-PVR $53.8%{\pm}5.5%$, P=0.002). The postoperative QRS duration showed a tendency to decrease (pre-PVR $162.7{\pm}26.4$ msec, post-PVR $156.4{\pm}24.4$ msec, P=0.124). QRS duration was greater than 180 msec in 6 patients prior to PVR. Of these, 5 patients showed a decrease in QRS duration following PVR; QRS duration was less than 180 msec in 2 patients, and QRS duration remained greater than 180 msec in 3 patients, including 2 patients with diffuse postoperative right ventricular outflow tract hypokinesis. Six patients had coexisting arrhythmias before PVR; 2 patients, atrial tachycardia; 3 patients, premature ventricular contraction; and 1 patient, premature atrial contraction. None of the patients presented with arrhythmia following PVR. Conclusion: The CTR and QRS duration reduced following PVR. However, QRS duration may not decrease below 180 msec after PVR, particularly in patients with right ventricular outflow tract hypokinesis. The CTR and ECG may provide additional clinical information on changes in right ventricular volume and/or pressure in these patients.

Impact of Pulmonary Arterial Elastance on Right Ventricular Mechanics and Exercise Capacity in Repaired Tetralogy of Fallot

  • Soo-Jin Kim;Mei Hua Li;Chung Il Noh;Seong-Ho Kim;Chang-Ha Lee;Ja-Kyoung Yoon
    • Korean Circulation Journal
    • /
    • v.53 no.6
    • /
    • pp.406-417
    • /
    • 2023
  • Background and Objectives: Pathophysiological changes of right ventricle (RV) after repair of tetralogy of Fallot (TOF) are coupled with a highly compliant low-pressure pulmonary artery (PA) system. This study aimed to determine whether pulmonary vascular function was associated with RV parameters and exercise capacity, and its impact on RV remodeling after pulmonary valve replacement. Methods: In a total of 48 patients over 18 years of age with repaired TOF, pulmonary arterial elastance (Ea), RV volume data, and RV-PA coupling ratio were calculated and analyzed in relation to exercise capacity. Results: Patients with a low Ea showed a more severe pulmonary regurgitation volume index, greater RV end-diastolic volume index, and greater effective RV stroke volume (p=0.039, p=0.013, and p=0.011, respectively). Patients with a high Ea had lower exercise capacity than those with a low Ea (peak oxygen consumption [peak VO2] rate: 25.8±7.7 vs. 34.3±5.5 mL/kg/min, respectively, p=0.003), while peak VO2 was inversely correlated with Ea and mean PA pressure (p=0.004 and p=0.004, respectively). In the univariate analysis, a higher preoperative RV end-diastolic volume index and RV end-systolic volume index, left ventricular end-systolic volume index, and higher RV-PA coupling ratio were risk factors for suboptimal outcomes. Preoperative RV volume and RV-PA coupling ratio reflecting the adaptive PA system response are important factors in optimal postoperative results. Conclusions: We found that PA vascular dysfunction, presenting as elevated Ea in TOF, may contribute to exercise intolerance. However, Ea was inversely correlated with pulmonary regurgitation (PR) severity, which may prevent PR, RV dilatation, and left ventricular dilatation in the absence of significant pulmonary stenosis.

Study of the Development of the Pulmonary Arteries following the Blalock-Taussig Shunt in Tetralogy of Fallot (활로씨 사징증 환자에서 Blalock-Taussig 단락술후 폐동맥의 발달에 관한 연구)

  • 정경영
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.594-600
    • /
    • 1989
  • Primary intracardiac repair of tetralogy of Fallot with low mortality and early good results, has been accomplished in recent years. But palliative procedures have been reserved for those hypoplastic pulmonary arteries, a hypoplastic left ventricle or anomalies of the coronary artery would make total correction difficult. And the Blalock-Taussig shunt operation is recognized as a standard and popular palliative procedure. I undertook a retrospective determination of the effect of the Blalock-Taussig shunt operation on the development of the main pulmonary artery and the right and left pulmonary arteries. Between January, 1980, and April, 1987, at the Severance Hospital, 16 patients were studied by cardiac catheterization and angiocardiography, before undergoing Blalock-Taussig shunting procedures for the palliation of severe symptoms of tetralogy of Fallot, and some time later, usually prior to a second procedure. The mean interval between catheterizations was 22.25 months. Patients with tetralogy of Fallot and pulmonary atresia or with an occluded shunt were not included. The primary and secondary angiograms of each patient were reviewed, and measurements of the diameter of the main pulmonary artery, the right and left pulmonary arteries, and the descending thoracic aorta were taken. The results are as follows; 1. The hematocrit decreased from 56.39% to 50.34%[p< 0.05], and the arterial oxygen saturation increased from 62.00 % to 81.31 %[p< 0.001] following shunt procedures 2. The ratio of the diameter of the right pulmonary artery plus the left pulmonary artery to the diameter of the descending thoracic aorta increased 1.30 k 0.28 times [p< 0.01]; but the ratio of the diameter of the main pulmonary artery to the diameter of the descending thoracic aorta increased 1.10 * 0.33 times, which was not. significant[p< 0.05]. 3. The interval between shunting and second catheterization was not related to the magnitude of change in the pulmonary arteries[r=0.141, p >0.05]. 4. The changes in the ratio of the diameter of the right pulmonary artery plus the diameter of the left pulmonary artery to the diameter of the descending thoracic aorta was inversely related to the initial ratio[r=0.757, p >0.001], but the change in the ratio of the diameter of the main pulmonary artery to the descending thoracic aorta was not related[r=0.059, p >0.05]. 5. There were no differences in enlargement of the pulmonary artery on the side of the shunt [ipsilateral] versus enlargement on the opposite side [p >0.05], nor according to the size of the shunt[p >0.05]. In conclusion, this study suggests that the Blalock-Taussig shunt is effective for the development of the right and left pulmonary arteries but not effective for the main pulmonary artery.

  • PDF

The Effect of Left Ventricular Volume on Postoperative Cardiac Function in Tetralogy of Fallot (활로씨 4징증의 좌심실용적이 수술후 심장기능에 미치는 영향)

  • Kim, Eung-Jung;No, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.211-222
    • /
    • 1988
  • Tetralogy of Fallot is a cyanotic congenital heart disease characterized by large ventricular septal defect[VSD] and stenosis of right ventricular outflow tract[RVOT] and the degree of RVOT stenosis and the state of pulmonary arteries are the major determinant of prognosis of this anomaly after operation. The sum of blood flow through RVOT and collateral flow from systemic arteries determine the total pulmonary blood flow and it is drained to left atrium and left ventricle. Therefore the degree of development of left ventricle not only reflects pulmonary blood flow and the status of peripheral pulmonary arteries but also affects postoperative prognosis as a systemic ventricle. In this article, left ventricular volume and its influence on postoperative cardiac function in tetralogy of Fallot were studied in 34 patients operated on at Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital in 1985. Mean age of the patients was 5 1/12*3 9/12 years[range 9/12 - 14 8/12 years], mean body surface area[BSA] 0.65*0.20m2[range 0.38 - 1.22m2], mean body weight 15.6k6.48kg[range 7.0 - 36kg]and mean hematocrit 50.6*9.77%[range 32.0 - 73.5%]. Left ventricular end-diastolic volume[LVEDV] of them were from 11.2 to 113cc and there was a good linear correlation between BSA[m2, X]and LVEDV[cc, Y][Y= - 20.0+923x, r= 0.84, p < 0.005]. Mean LVEDV/m2 was [57.6 * 18.3 cc / m2[range 28.7 - 95.8 cc / m2] and there was a significant reduction of volume compared with normal value. As body surface increases, there was a increasing tendency in LVEDV/m2 but there was no statistical significance. Mean total amount of postoperatively infused dopamine in these 33 patients[except one who expired postoperatively] was 65.6*74.5mg / kg and it was 40.6*44.0mg / kg in routine RVOT widening group [Group I] and 205*49.3mg / kg in transannular RVOT widening group[Group II]. There was a statistically significant difference between two groups. In group I patients there was a good linear inverse correlation between dopamine total amount[mg / kg, Y] and LV volume[cc / m2, X] [Y = 150 - 1.89 X, r = - 0. 77, p < 0.005]. But there were no correlations between dopamine total amount and Hct, cardiopulmonary bypass time and aorta cross clamp time. In conclusion, the patient with small preoperative left ventricular volume required more amount of dopamine as an inotropic agent for the maintenance of a cardiac function in postoperative period. But this is a result of immediate postoperative period and does not reflect the long term effect of left ventricular volume in tetralogy of Fallot. There must be more study for the evaluation of its long term effect.

  • PDF

Detinitive Repair of Tetralogy of Fallot in Infancy - Transventricular approach - (유아기에 시행한 팔로씨 사증의 심실절개를 통한 완전교정술)

  • 이정렬;김준성;김용진;노준량;배은정;노정일;윤용수;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.139-145
    • /
    • 2004
  • This study describes our surgical results of transventricular complete repair of tetralogy of Fallot in infants. Material and Method: Eight hundred and forty children underwent complete repair of TOF between January 1990 and April 2002 in our institute. One hundred sixty infants of them were included to this survey. Mean age at repair was 8.1$\pm$2.6 months (3∼12). Correction was accomplished through a short right ventriculotomy less than 30% of ventricular height in all patients. A transannular patch was necessary in 78 patients (49%). Result: There were four early deaths. There were no late deaths. Follow-up with mean duration of 66 months was completed in all survivors, All patients are currently in New York Heart Association functional class I or II. Twenty patients required late reoperations. Actuarial freedom from reoperation at 1 and 10 years were 94% and 87% respectively. Two-dimensional and Doppler echocardiographic follow-up studies showed good right ventricular function in all patients except three. Conclusion: Our results suggested that early complete repair of TOF yield the acceptable results with low mortality and morbidity. Transventricular repair of intracardiac pathology can be safely applied to these patient population, yielding good postoperative right ventricular function.