• Title/Summary/Keyword: test structure

Search Result 8,654, Processing Time 0.035 seconds

A Development of a Variable Dynamic Force Type Exciter for Modal Test of a Large Structure (대형구조물 동특성 실험을 위한 가변 동하중 가진 시스템 개발)

  • Son, S.W.;Lee, H.G.;Choi, C.H.;Kang, D.E.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.826-831
    • /
    • 2002
  • In order to investigate the dynamic characteristics of real structure, many dynamic engineer had been interested in modal test however it is not easy to perform dynamic test of large structure because of many difficulties such as unsatisfied excitation force in global mode frequency range, measurement of dynamic force and so on. Therefore. new type vibration exciter with variable stiffness support system and dynamic force was developed to provide a improved experimental environment for a large and complex structure. The developed exciter improved from two viewpoint, dynamic performance and utility convenience. its characteristics was shown in this paper.

  • PDF

Shaking Table Test of Small Scale RC Structure with Tuned Liquid Damper (동조액체 감쇠기를 설치한 철근콘크리트 축소모델의 진동대 실험)

  • Woo, Seang-Sik;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.113-116
    • /
    • 2005
  • In this study, in order to. investigate the effectiveness af tuned liquid damper (TLD) for the seismic performance enhancement af the existing reinforced concrete (RC) apartment structure which is nat seismically designed, shaking table test was conducted for the small scale five stary RC structure with TLD. TLD model was constructed to. have the frequency tuned to. the first modal frequency af the structure, $2\%$ mass ratio. af the first modal mass, and 0.08 liquid depth ratio. White noise with $0.2\~5Hz$ frequency bandwidth tests were performed using the shaking table at Korea Institute af Machinery and Materials, and the displacement and absolute acceleration af each floor were measured. Test results indicate that mare than $30\%$ seismic responses reduction can be achieved using TLD for RC structure under white noise.

  • PDF

A Study on the Structural Dynamic Modification of Sub-structure of Clean Room Considering Vibration Criteria (반도체 초정밀장비의 진동허용규제치를 고려한 지지구조의 동특성 개선에 관한 연구)

  • 손성완;이홍기;백재호
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.2
    • /
    • pp.25-30
    • /
    • 2003
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. This high technology equipments require very strict environmental vibration criteria in proportion to the accuracy of the manufacturing. In this paper, the dynamic analysis and modal test were performed to evaluate the dynamic properties of the constructing clean room structure. Based on these results, a structural dynamic modification(SDM) were required to satisfiy the vibration allowable limit for pression machine. Therefore, in order to improve the dynamic stiffness of clean room structure, the VSD system which can control the force applied on structure, were adopted and its utility were proved from dynamic test results of the improved structure after a modification work.

  • PDF

Experimental Modal Test on a Scale Model of Floating Structure

  • Park, Soo-Yong;Song, Hwa-Cheol;Park, Dong-Cheon
    • Journal of Navigation and Port Research
    • /
    • v.36 no.2
    • /
    • pp.89-95
    • /
    • 2012
  • Identification of the modal properties of a structural system has received much attention over the years because of its importance in structural model updating, structural health monitoring and structural control. This paper presents experimental modal test results such as natural frequencies and mode shapes of a scale model of floating structure. A modal testing is performed on the structure and modal parameters for the structure are extracted from the measured data. The results are compared to a finite element model and the correlation between the measured and analytical modal parameters is investigated.

Topology optimization of tie-down structure for transportation of metal cask containing spent nuclear fuel

  • Jeong, Gil-Eon;Choi, Woo-Seok;Cho, Sang Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2268-2276
    • /
    • 2021
  • Spent nuclear fuel, which can degrade during long-term storage, must be transported intact in normal transport conditions. In this regard, many studies, including those involving Multi-Modal Transportation Test (MMTT) campaigns, have been conducted. In order to transport the spent fuel safely, a tie-down structure for supporting and transporting a cask containing the spent fuel is essential. To ensure its structural integrity, a method for finding an optimum conceptual design for the tie-down structure is presented. An optimized transportation test model of a tie-down structure for the KORAD-21 metal cask is derived based on the proposed optimization approach, and the transportation test model is manufactured by redesigning the optimized model to enable its producibility. The topology optimization approach presented in this paper can be used to obtain optimum conceptual designs of tie-down structures developed in the future.

Airframe Durability Certification for Export Basic Trainer (수출형 기본 훈련기에 대한 기체구조물 내구성 입증)

  • Park, Taegyu;Park, Jeongkyu;Moon, Changoh
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.19-24
    • /
    • 2015
  • Export basic trainer was designed to add armed configuration required by customer. Design configuration of main wing was changed to satisfy changed internal load caused by armed configuration. It was verified that design changed main wing airframe of export basic trainer satisfy the requirement through the structural detail analysis, structural ground test and flight test. This paper presents the durability test procensure and test result for the main wing of export basic trainer.

Development of Analysis Model and Comparison of Seismic Analysis Responses with Test Results for an Isolated Test Structure for Liquid Reactor (액체금속로 면진 시험구조물의 해석모델링 개발 및 지진응답비교)

  • Yoo, Bong;Lee, Jae-Han;Koo, Gyeong-Hoi
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.411-418
    • /
    • 2001
  • The initial analysis frequencies of the isolated test structure for seismic excitation tests give quite higher values to the actual modal test results. This large difference was redulted from some uncertainties in analysis modeling of several connection regions between column and upper beam, cross bars of the isolated structure. A modified simple analysis model is developed representing the actual dynamic behaviors of the test model, and the seismic analysis responses of the simple model are compared with those of the seismic tests.

  • PDF

The Evaluation of the Road Noise of the Automotive Tire by Subjective Test (주관적인 시험에 의한 자동차 타이어 도로소음 평가)

  • Lee, Tae-Keun;Kim, Byoung-Sam;Cho, Tae-Jea
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.91-96
    • /
    • 2008
  • As a remarkable reduction of the vehicle noise, the important of tire noise which is generated from the vehicle and the necessity of the research for the noise reduction is being emphasized. In this study, the road noise which is excited by the interaction between tire and road has been studied. The subjective test(feeling test) according to SAE J1060 rating scale is applied to the evaluation of the road noise. The combination of the several tires and vehicles are made to consider the effect of the vehicle suspension and the tire structure for road noise. The vehicles with 3-different suspension system are applied to road noise test and the eight kinds of tires are selected. As the results, the effects of the vehicle suspension and tire structure which affects on road noise are investigated.

Experimental study for application of the punch shear test to estimate adfreezing strength of frozen soil-structure interface

  • Park, Sangyeong;Hwang, Chaemin;Choi, Hangseok;Son, Youngjin;Ko, Tae Young
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.281-290
    • /
    • 2022
  • The direct shear test is commonly used to evaluate the shear behavior of frozen soil-structure interfaces under normal stress. However, failure criteria, such as the Mohr-Coulomb failure criterion, are needed to obtain the unconfined shear strength. Hence, the punch shear test, which is usually used to estimate the shear strength of rocks without confinement, was examined in this study to directly determine the adfreezing strength. It is measured as the shear strength of the frozen soil-structure interface under unconfined conditions. Different soils of silica sand, field sand, and field clay were prepared inside the steel and concrete ring structures. Soil and ring structures were frozen at the target temperature for more than 24 h. A punch shear test was then conducted. The test results show that the adfreezing strength increased with a decrease in the target temperature and increase in the initial water content, owing to the increase in ice content. The adfreezing strength of field clay was the smallest when compared with the other soil specimens because of the large amount of unfrozen water content. The field sand with the larger normalized roughness showed greater adfreezing strength than the silica sand with a lower normalized roughness. From the experiment and analysis, the applicability of the punch shear test was examined to measure the adfreezing strength of the frozen soil-structure interface. To find a proper sample dimension, supplementary experiments or numerical analysis will be needed in further research.

Modal Identification of a Slender Structure using the Proper Orthogonal Decomposition Method (Proper Orthogonal Decomposition 기법을 이용한 세장한 구조물의 모드인자 파악)

  • Ham, Hee-Jung
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.135-141
    • /
    • 2008
  • In this paper, the Proper Orthogonal Decomposition (POD) method, which is a statistical analysis technique to find the modal characteristics of a structure, is adapted to identify the modal parameters of a tall chimney structure. A wind force time history, which is applied to the structure, is obtained by a wind tunnel test of a scale down model. The POD method is applied on the wind force induced responses of the structure, and the true normal modes of the structure can be obtained. The modal parameters including, natural frequency, mode shape, damping ratio and kinetic energy of the structure can be estimated accurately. With these results, it may be concluded that the POD method can be applied to obtain accurate modal parameters from the wind-induced building responses.

  • PDF