A Study on the Corrosion Resistance Test of Smoke Detectors (연기감지기의 내식시험에 관한 연구)

  • Kim, Hyeong-Gweon;Yoon, Hun-Ju;Kwon, Seong-Pil;SaKong, Seong-Ho;Back, Chang-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF

A Study on the Establishment of Shore Hardness Standards (쇼어경도표준의 확립에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung;Bong, Haheon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.15 no.3
    • /
    • pp.127-135
    • /
    • 2002
  • Shore hardness test was developed in 1906 to overcome the limit of Brinell hardness test. However, the detailed requirements on the tester was not clearly specified except the scale, i.e., 100 HS for high carbon steel and 10 HS for soft brass. As a result, the shore hardness was used for quite long time without well established standards. For the establishment of hardness standards, standard tester, standard procedure, and standard hardness block must be provided. So far the standard of Shore hardness was maintained by correlating Shore hardness scale to Vickers hardness through converting equation. This is the so called converted Shore hardness and it is not the true Shore hardness standard strictly. In this paper, the possibility of establishing Shore hardness standard based on the Shore standard hardness tester is reported.

Developing a Test Tool for Electronic Book Standard Conformance (전자책 표준 적합성 도구의 개발)

  • 김재경;손원성;임순범;김성혁;최윤철
    • The Journal of Society for e-Business Studies
    • /
    • v.9 no.1
    • /
    • pp.269-284
    • /
    • 2004
  • EBKS(Electronic Book of Korea Standard) 1.0 which was established in July 2001 passed the industry standard deliberation of agency for technology and standards of Korea industry in July 2002. EBKS is now established as KS X6100 representing the Korea standard of electronic book of Korea. Therefore, Conformance test and certification procedure is required whether electronic books and documents which follow KS X 6100 are conform to specification of the standard. In the paper, we define conformance clause which is a basis for conformance test and standard electronic book schema. As a result, electronic book writers can produce more conformable documents to the specification and goal of electronic book standard by using the conformance clause, and service provider can effectively perform the conformance test by using standard electronic book schema.

  • PDF

The Status and Analysis of PV Module's Certificate (결정질 태양전지모듈 인증시험 현황 및 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.55-55
    • /
    • 2009
  • In this paper, we introduce the status of certificate test on crystalline silicon photovoltaic, module in Korea. Up to 5. 2009, about 200 models have passed certificate test under KS C IEC61215 standard. Most products are from Korea, Japan, China. And some are from USA, German and Taiwan. A few environmental test items' results and standard test methods will be discussed. The detail discussion will be shown in the following paper.

  • PDF

A Study on the Application of a Dementia Prevention Program and Its Effect Test (치매예방 프로그램 운영 및 효과검증 연구)

  • Hwang, Ok-Nam;Yoon, Sook-Rye;Hwang, Hye-Yeon;Nam, Ki-Seok
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.5 no.2
    • /
    • pp.156-165
    • /
    • 2002
  • The objective of this study was to apply a dementia prevention program to the subjects who were suspected of dementia and test its effect. This study was one group pretest-posttest design. The dementia prevention program was applied for 20 weeks to the 19 subjects who were suspected of dementia after a screen test among 638 subjects enrolled in 10 senior citizen's centers in G city. The scores of self-efficacy, cognition, quality of life were measured before and after the program. The data collected were analyzed using a SPSS (statistical analysis system) program, and frequencies, averages and standard deviations were obtained. The differences of the scores of the pretest and posttest were analyzed with Mann-Whitney test and sign test. The results were as follows: 1. After the program, the average score of self-efficacy was increased from 75.31 (standard deviation 11.99) to 84.26 (standard deviation 13.92). 2. There are no differences between the average scores of physical and psychological quality of life, however, the average score of social quality of life was slightly increased from 2.25 (standard deviation 0.40) to 2.53 (standard deviation 0.43), and the overall score of social quality of life was low. 3. The average score of cognition was significantly increased from 21.00 (standard deviation 2.60) to 24.58 (standard deviation 3.37), thus, it was found that the program was effective to improve the cognition level. 4. The score differences of self-efficacy, quality of life, cognition between the pretest and posttest were statistically significant. 5. The score differences of quality of life between the pretest and posttest were found to be dependent on marital status, exercise and regular checkup yes or no. In conclusion, the program was effective to prevent the subjects suspected of dementia from dementia.

  • PDF

Analysis on the Performance Evaluation Trends of Heat Pumps and the Test Standards of a Geothermal Heat Pump in Korea (히트펌프 성능 평가 동향과 국내 지열원 히트펌프 성능 평가 규격 및 제도 분석)

  • Kang, Shin-Hyung;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.31-38
    • /
    • 2017
  • The heating and cooling air conditioning field has been increasing the problems of energy consumption and global warming in the world. A geothermal heat pump has been known as one of the highest efficient heating and cooling system. In this study, the analysis about the test standards of the geothermal heat pump of the Republic of Korea was executed. From the research, the following results were given. It is needed to address the domestic test standard for direct heat exchange geothermal heat pump. Water to air multi geothermal heat pump test standard was only developed in Korea. The test standard to calculate a seasonal energy efficiency ratio for cooling period and heat seasonal performance factor for heating period should be newly developed to estimate actual annual energy consumption and $CO_2$ emission.

Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles (토목 발파가 소음, 진동, 부유 분진에 미치는 영향)

  • Jeong, Jin Do;Jeong, Yeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

Measurement of Solar Cell Using LED-based Differential Spectral Responsivity Comparator under High Background Irradiance

  • Zaid, Ghufron;Park, Seong-Chong;Lee, Dong-Hoon;Park, Seung-Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.293-294
    • /
    • 2009
  • The spectral responsivity of solar cells has been measured under high background irradiance using an LED-based differential spectral responsivity Comparator (DSR-C). The comparator developed is fully automated and has some advantages: It does not need a chopper to modulate the light. Unlike the conventional method, it does not require a monochromator to select wavelength. It covers a wavelength range up to 1200 nm. The wavelength range of the comparator is limited by the spectral power distribution of the LEDs and the spectral responsivity of the standard detector. An active temperature control was utilized to meet the specified standard conditions of solar cell test. This work shows the effect of different levels of background irradiance on the spectral responsivity and the importance of same background irradiance for solar cell test as specified by the corresponding standard.

  • PDF

Establishment of Marine Ecotoxicological Standard Method for Larval Fish Survival Test (어류 자어의 사망률을 이용한 해양생태독성시험 방법에 관한 연구)

  • Park, Gyung-Soo;Kang, Ju-Chan;Yoon, Sung-Jin;Lee, Seung-Min;Hwang, Un-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.140-146
    • /
    • 2008
  • Marine ecotoxicological standard method using fish larvae was established with the standard test species of Oryzias latipes(Japanese Medaka) and Paralichthys olivaceus(flounder) and with the 7 day $LC_{50}$ as endpoint. Test method referred to the USEPA(1994) with the replacement of test species found in the Korean water. Standard test species were selected in terms of the species supply and ecological importance in Korean waters. Japanese medaka can be reared with small tanks in the lab and has wide tolerance on salinity, and flounder eggs can be easily obtained from commercial fish hatcheries. General conditions for larval fish toxicity test are as follows. The possible salinity ranges for toxicity test were $0{\sim}35\;psu$ for medaka and >20 psu for flounder. Test type was designated as static non-renewal test if the dissolved oxygen in the test chamber does not fall below 4.0 mg/L. Ages of test species were selected as 7 days after hatched for medaka(about 5 mm TL) and 25 days for flounder(about 10 mm TL) because of the low natural mortality after these periods. Test can be accepted when the survival rates are over 80% in control. Also, species sensitivity on standard reference materials(copper, cadmium or zinc) must be provided with the toxicity test results.

Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364 (IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰)

  • Kim, Doo-Ung;Ryu, Kyu-Sang;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.