• Title/Summary/Keyword: test standard

Search Result 8,418, Processing Time 0.038 seconds

Implementation of PXIe platform based portable Automatic Test Equipment to improve reliability

  • Gwon, Hyeok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, we propose a development method of portable Automatic Test Equipment based on PXIe platform. Legacy VME form factor structured test equipment has limited reuse and expansion of modules due to unapplied bus specification. In particular, these limitations can cause development periods and costs to increase, and the reliability of environmental conditions is lacking due to non-standard modules. The test equipment of the proposed PXIe platform can use diverse COTS modules to shorten the development period and minimize the instability between developments. The PXIe development module works with standard Xilinx FPGAs, PXIe Windows device drivers, and applications on standard PXIe buses. The use of standard bus and COTS modules increases scalability and reusability, enabling rapid development and excellent maintenance. Through the test, we show the proposed test equipments can be implemented efficiently between the development processes and proved their reliability through function tests and environmental tests.

A Comparative Study between Korean Standard Eye Test and Test Chart 2000 Pro (Test Chart 2000 Pro와 한국 표준 검안법의 일치도 비교 연구)

  • Kang, Ji-Hun;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.69-80
    • /
    • 2009
  • Purpose: We investigated validity of a monitor-based computer eye test program, Test Chart 2000 Pro (developed by Thomson Software Solutions, UK). Methods: We chose ten common eye tests of the Test Chart 2000 Pro and Korean Standard Eye Test, applying them to same subject groups each by each, followed by comparison and analyses of agreement degree of the results. Results: Among the ten eye tests, Snellen Chart, Cross-cyl target, Duochrome test, Fan and Block test, and Random dot stereograms showed statistically significant agreement between both the Korean standard eye test method and Test Chart 2000 Pro. On the other hand, some disagreements were found between the two eye test methods in LogMAR Chart, Single Letter Chart, Phoria Test, Fixation Disparity Test, and Worth 4 Dot Test. Conclusions: Comparing to the Korean Standard Eye Test that consists of Han eye chart and Phoroptor, validity of the Test Chart 2000 Pro is not so high. Further improvements of the Test Chart 2000 Pro in accuracy are required.

  • PDF

Standard Conformance Test System for e-Business Solutions Supporting ebXML (ebXML 지원 솔루션의 표준적합성 테스트 시스템 구축)

  • Kim, Dong-Soo;Yun, Jung-Hee
    • Journal of Information Technology Services
    • /
    • v.2 no.1
    • /
    • pp.85-97
    • /
    • 2003
  • This research has designed and implemented the standard conformance test system for e-Business solutions that supports the ebXML, which is currently being focused on as the leading electronic commerce framework. The adoption of standards such as ebXML is probably the best way to achieve interoperability among electronic commerce systems, and more and more e-Business solutions around the world are supporting ebXML. This research primarily discusses the concept and needs for the standard conformance tests on e-Business solutions. The standard conformance test system is developed based on the detailed specifications of the ebXML framework. This system was used to test commercial e-Business solutions supporting ebXML. The system implemented in this research will provide a significant basis for the standard conformance certification of e-Business solutions, and could also provide clear decision criteria for e-Business solutions currently in market, thus activate the overall e-Business market.

Best Measurement Capability and Standard Test Facility for the Water-level Gauges (수위계 표준시험장치 개발 및 최고측정능력에 관한 연구)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.10
    • /
    • pp.1012-1017
    • /
    • 2007
  • Rain data and water-level data are importantly used for dam operation at flood period. Because dams are directly controlled by the water-level data, the characteristic of the water-level gauges is necessary to be managed. Thus, we developed the standard test facility and method for testing the water-level gauges which are a float type, a supersonic type and a radar type. And we calculated the uncertainty of the standard test facility to maintain the accuracy of water-level gauges. Through development of this facility, we could obtain the characteristics and the calibration factor of the water-level gauges. And, this study showed that the standard test facility can be widely used for dam operation and basin management.

Effect of complex sample design on Pearson test statistic for homogeneity (복합표본자료에서 동질성검정을 위한 피어슨 검정통계량의 효과)

  • Heo, Sun-Yeong;Chung, Young-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.4
    • /
    • pp.757-764
    • /
    • 2012
  • This research is for comparison of test statistics for homogeneity when the data is collected based on complex sample design. The survey data based on complex sample design does not satisfy the condition of independency which is required for the standard Pearson multinomial-based chi-squared test. Today, lots of data sets ara collected by complex sample designs, but the tests for categorical data are conducted using the standard Pearson chi-squared test. In this study, we compared the performance of three test statistics for homogeneity between two populations using data from the 2009 customer satisfaction evaluation survey to the service from Gyeongsangnam-do regional offices of education: the standard Pearson test, the unbiasedWald test, and the Pearsontype test with survey-based point estimates. Through empirical analyses, we fist showed that the standard Pearson test inflates the values of test statistics very much and the results are not reliable. Second, in the comparison of Wald test and Pearson-type test, we find that the test results are affected by the number of categories, the mean and standard deviation of the eigenvalues of design matrix.

An Experimental Study on Detection of Defects in Weldzone (용접부 결함 검출에 관한 실험적 연구)

  • 남궁재관
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.56-63
    • /
    • 2003
  • In this study, an automatic ultrasonic testing system is used to detect the defects of the natural flaw test specimen and of the artificial flaw test specimen. We evaluate the detection performance of the acceptance standard for the natural flaw test specimen and of the acceptance standard for the artificial flaw test specimen. We also study the potential problems of those acceptance standards. The results indicate that the acceptance standard for the detection of defects in weldzone is good then the sensitivity correction is performed and that we must clearly specify special check points of the acceptance standard for the system in use.

A Study of Standardization of Floor Slip Test method using O-Y·PSM (경사인장형 바닥 미끄럼 시험방법의 표준화에 관한 연구)

  • Shin, Yun-Ho;Kang, Yong-Hak;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.95-96
    • /
    • 2016
  • The floor slip test method using O-Y·PSM was developed based on the risk assessment and sense of slip by the users implementing actions such as changing walking direction on a floor. This test method is regulated under the Korea Industrial Standard KS M 3510, and in the Korea Industrial Standard KS F 3230, the article of KS M 3510 is cited. Yet, in the standard, the surface condition of test or slip adjustment method is merely mentioned or difficult to be found, and thus it creates confusion in floor slip test using O-Y·PSM. Therefore, this study is to provide the useful data to revise the relative standard through the standardization study including various surface conditions of sample and slip adjustment method used in floor slip test method using O-Y·PSM.

  • PDF

Analysis on the Vibration Transmission Characteristics of the Standard Test Building by Using Standard Impact Source (경량 및 중량 충격원에 의한 표준 실험동의 진동전달 특성 분석)

  • Jin, Pil-Hwa;Kim, Heung-Sik;Kim, Do-Heong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.371-371
    • /
    • 2006
  • The purpose of this study is to provide a fundamental data for efficient and economical reduction method and predict ion method of floor impact noise. In order to get the useful results, the measurement on the vibration transmission characteristics of standard test building with four rooms by using heavy and light-weighed impact source were carried out. In this measurement various conditions such as the change of test structure construction, the pick-up sensor location, the excitation posit ion, and the resilient material types were applied to get the vibration characteristics transmitted from excitation room to adjacent rooms.

  • PDF

A Study on the Design of the rated insulation voltage of 690V for the low-voltage switchgear and controlgear (저압기기 정격절연전압 690V 개발시 고려사항에 대한 연구)

  • Kim, Myoung-Seok;Kim, Jong-Yeok;Park, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.961-963
    • /
    • 2000
  • Most of the application standard of the low-voltage devices have applied one the IEC standard another the UL standard. European union applied the IEC60947-1 standard has not exceed 1000V a.c. or 1500V d.c.. Therefore. it is necessary to the low-voltage device has expended for rated operational voltage with our products. The export of European market shall be made for the CE-Marking in accordance with IEC60947-1 ( Low-voltage switchgear and controlgear). We shall be considered for the requirement with the IEC standard. In this time to study for power supply system at EU ( European union. At that time for design and development in order to the construction and test method among the study for the rated insulation voltage at less then 690V.

  • PDF

Design of an Automatic Test System for Electronic Equipments in Vehicles (승용차용 전장시험 자동화 시스템 설계)

  • 이창훈;김유남
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.131-138
    • /
    • 2001
  • The performance analysis of an electronic equipment test is very complicate due to the variety o vehicles. In this study, automatic design system for the electronic equipment test has been carried out using the standard load patterns. For the test, standard signal patterns for each item are modeled. The test items can be decided by the user by means of these patterns. Also, engineering software modules are developed and proved to be very efficient for analyzing the test results statistically. Experiments are performed for the test system in the vehicle assembly line. By analyzing the test results, it is found that bad samples can be detected without failure. Also, the engineering software modules provide an analytical tool for the automation of the test process.

  • PDF