• 제목/요약/키워드: test procedures

검색결과 1,849건 처리시간 0.03초

Comparison between Visual Inspection of Cervix and Cytology Based Screening Procedures in Bangladesh

  • Nessa, Ashrafun;Nahar, Khadiza Nurun;Begum, Shirin Akhter;Anwary, Shahin Ara;Hossain, Fawzia;Nahar, Khairun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7607-7611
    • /
    • 2013
  • Background: Cervical cancer continues to be a major problem in Bangladesh with approximately 18,000 new cases annually of which over 10,000 women die from it. Visual inspection of the cervix after 3-5% acetic acid (VIA) application is a simple and easy to learn method for cervical cancer screening, although cytology-based screening is more often applied in developed countries where it has successfully reduced the prevalence of cervical cancer. Objective: To compare the efficacy of VIA and cytology-based primary methods for cervical cancer screening in Bangladesh. Materials and Methods: This hospital based comparative study was conducted at the VIA centre and Colposcopy Clinic of Bangabandhu Sheikh Mujib Medical University (BSMMU) from October 2008 to October 2010. Results: Among 650 women, 74 (11.4%) were VIA+ve and 8 (1.2%) had abnormalities in their Pap smear reports. During colposcopy, 38 (7.7%) women had different grades of CIN and 4 (0.6%) had cervical cancer. The gold standard histology findings proved 20 women had CIN I, 14 had CIN II/II and 4 had cervical cancer. Among the 38 histology diagnosed abnormalities, VIA test could identify 30 abnormalities including two cervical cancers. However, Pap smear could detect only 8 cases of histological abnormalities (2 low grade and 6 had high grade lesion) and it missed all the cervical cancer cases. The sensitivity and specificity of VIA were 88.9% and 52.1%. The positive predictive value (PPV) and negative predictive value (NPV) were 41.0%, and 92.6% respectively. Moreover, the sensitivity, specificity, PPV and NPV of Pap smear were 33.3%, 95.8%, 75.0% and 79.3%, respectively. Conclusions: VIA test should be used as the primary screening tool even with its low sensitivity and specificity in low resource countries like Bangladesh. False positive results may be greater, but overtreatment can be minimized by colposcopy evaluation of the VIA positive women.

독해·영작 중심의 교양영어프로그램이 한국 대학생의 영어자기효능감에 미치는 영향 (Exploring the Effects of Reading & Writing English Program on Self-Efficacy of Korean University Students)

  • 신영헌;현일선
    • 한국콘텐츠학회논문지
    • /
    • 제20권9호
    • /
    • pp.99-106
    • /
    • 2020
  • 성공적인 외국어 학습을 위해 필요한 요소 중 하나로 자기효능감이 주목받아 왔지만, 이와 관련된 연구 중 다수는 중등학교 학생들을 대상으로 수행된 연구들이다. 본 연구는 영어 독해와 작문 중심의 교양영어프로그램이 대학 신입생들의 자기효능감에 미치는 영향을 살펴보았다. 자료 수집을 위하여 교양영어프로그램을 수강하는 중급반 학생을 대상으로 사전-사후 설문을 실시하였고, 해당 학생들을 지도하는 교수자들을 대상으로 영작 지도 유형을 파악하기 위한 인터뷰도 실시하였다. 학생들의 자기효능감의 사전-사후 차이를 살펴보기 위하여, 대응표본 t-test로 분석하였으며, 일원분산분석으로 교수자의 지도 유형에 따른 차이가 있는지를 통계적으로 확인하였다. 그 결과, 독해·작문 중심의 교양영어프로그램이 중급반에서 영어를 학습하는 학생들의 자기효능감에 긍정적인 영향을 미쳤고, 교수자의 영작과제 부여 횟수와 운영방식에 따른 차이가 확인되었다. 본 연구의 결과를 토대로, 신입생을 대상으로 하는 교양영어 수업에서 학습자들의 성공적인 학습 경험을 높일 수 있는 다양한 유형의 과제 개발과 효과적인 교수자의 피드백 방식 등에 대한 후속 연구가 필요하며, 이는 학습자의 자기효능감을 높이는 데에 있어서 보다 효과적인 교양영어 수업 모델 개발로 이어질 것이다.

BioAPl기반 시스템 모듈을 검증하기 위한 적합성시험 방법 연구 (A Study on Conformance Testing Method to Verify the BioAPI Based System Module)

  • 이유영;권영빈
    • 정보처리학회논문지B
    • /
    • 제11B권7호
    • /
    • pp.759-768
    • /
    • 2004
  • 생체인식기술을 응용한 제품이 다양해지면서 상호운용성의 문제가 제기되어 국제표준화가 진행중인 BioAPl(Biometric Application Pro-gramming Interface)를 기반으로 한 생체인식 제품의 개발이 증대되고 있다. 그러나 BioAPl를 적용하여 개발된 제품에 대한 성능 측정 및 표준규격의 적합성 여부에 대한 신뢰성 있는 평가 도구가 마련되어 있지 않은 상태이다. 본 논문은 생체인식시스템이 BioAPl 규격의 요구사항 및 기준에 얼마나 만족하여 개발하였는가를 검증하기 위한 적합성시험 방법을 연구하였다. 제안된 적합성 시험기술의 첫 번째는 BioAPl명세서가 제공하는 각 함수들을 제대로 구현하였는가에 대한 확인과 사용여부를 평가하는 것이다. 이것은 응용에서 APl(Application Provider Inter-face)함수를 호출하면 프레임워크를 통해 BSP(Biometric Service Provider)를 실행하는 것으로 이때 파라미터와 선행함수의 선택이 필요하다. 두 번째는 BioAPl의 해당 테스트케이스를 분석하여 모듈관리, 핸들기능, 검증기능에 대한 시나리오를 평가하는 것이다. 실험은 BioAPl 컨소시엄에서 제공하는 샘플프로그램과 상용 지문검증시스템의 BSP를 사용하여 제안하는 적합성 평가 방법에 대한 실험을 수행하였다. 이에 따라 BioAPl를 기반으로 한 BSP들이 요구사항에 적합하게 개발되었는지를 판단할 수 있었다.

삼차신경손상의 온도역치검사에 대한 예비연구 (A Pilot Study for Thermal Threshold Test of Trigeminal Nerve Injuries)

  • 김미은
    • Journal of Oral Medicine and Pain
    • /
    • 제37권4호
    • /
    • pp.243-250
    • /
    • 2012
  • 임플란트 수술이나 발치 같은 침습적인 치과치료로 인한 삼차신경 손상의 증가는 최근 치과계의 가장 민감한 문제의 하나로서 향후 법적인 문제로 까지 이어질 수 있다. 그러므로 신경손상에 대한 객관적이고 신뢰성 있는 평가 즉, 정량적 감각신경 검사(quantitative sensory testing)의 필요성이 강조되고 있으며, 온도역치 검사는 QST의 필수 항목으로 구강영역에서도 신뢰성이 입증되어 있다. 국내에서는 삼차신경손상과 관련한 온도역치 검사에 대한 보고가 아직 없기에, 본원에서 시행한 일부 증례의 온도역치 검사의 결과를 평가하고자 하였다. 2011년 5월부터 2012년 10월까지 단국대학교 치과대학 부속 치과병원 구강내과에 내원한 삼차신경손상이 의심되는 환자중 온도역치 검사를 시행한 18명의 환자 자료를 분석하였다. 환자들의 냉인지역치(cold detection threshold, CDT)는 이환측이 비이환측에 비해 유의하게 낮았으나 온인지역치(warm detection threshold, WDT), 냉통각역치(cold pain threshold, CPT), 열통각역치(heat pain threshold, HPT)는 통계적 차이를 보이지 않았다. 향후 더 많은 피검자를 대상으로 온도 자극과 관련하여 감각저하나 감각과민, 통각저하나 통각과민 같은 유형별 비교 연구가 필요하다.

olymerization behavior and thermal characteristics of two new composites at five temperatures: refrigeration to preheating

  • Jafarzadeh-Kashi, Tahereh Sadat;Mirzaii, Marzieh;Erfan, Mohmmad;Fazel, Akbar;Eskandarion, Solmaz;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.216-220
    • /
    • 2011
  • PURPOSE. Heat of composite polymerization (HP) indicates setting efficacy and temperature increase of composite in clinical procedures. The purpose of this in vitro experimental study was to evaluate the effects of 5 temperatures on HP of two new composites. MATERIALS AND METHODS. From each material (Core Max II [CM] and King Dental [KD]), 5 groups of 5 specimens each were prepared and their total HPs (J/gr) were measured and recorded, at one of the constant temperatures $0^{\circ}C$, $15^{\circ}C$, $23^{\circ}C$, $37^{\circ}C$ and $60^{\circ}C$ ($2{\times}5{\times}5$ specimens) using a differential scanning calorimetry (DSC) analyzer. The data were analyzed using a two-way ANOVA, a Tukey's test, an independent-samples ttest, and a linear regression analysis (${\alpha}=0.05$). RESULTS. No polymerization reactions occurred at $0^{\circ}C$; then this temperature was excluded from statistical analyses. The mean HP of the remaining 20 KD specimens was $20.5{\pm}14.9$ J/gr, while it was $40.7{\pm}12.9$ J/gr for CM. The independent-samples t-test showed that there were significant differences between the HP of the two materials at the temperatures $15^{\circ}C$ (P=.0001), $23^{\circ}C$ (P=.0163), $37^{\circ}C$ (P=.0039), and $60^{\circ}C$ (P=.0106). Linear regression analysis showed statistically significant correlations between environment temperatures and HP of CM ($R^2=0.777$). CONCLUSION. Using CM is advantageous over conventional composite because of its better polymerization capacity. However due to its high HP, further studies should assess its temperature increase in vivo. Preheating KD is recommended. Refrigerating composites can negatively affect their polymerization potential.

EFFECT OF CASTING PROCEDURE ON SCREW LOOSENING OF UCLA ABUTMENT IN TWO IMPLANT-ABUTMENT CONNECTION SYSTEMS

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.246-254
    • /
    • 2008
  • STATEMENT OF PROBLEM: The cast abutment has advantages of overcoming angulation problem and esthetic problem. However, when a gold-machined UCLA abutment undergoes casting, the abutment surfaces in contact with the implant may change. PURPOSE: The purpose of this study was to compare the detorque values of prefabricated machined abutments with gold-premachined cast-on UCLA abutments before and after casting in two types of internal implant-abutment connection systems: (1) internal hexagonal joint, (2) internal octagonal joint. Furthermore, the detorque values of two implant-abutment connection systems were compared. MATERIALS AND METHODS: Twenty internal hexagonal implants with an 11-degree taper and twenty internal octagonal implants with an 8-degree taper were acquired. Ten prefabricated titanium abutments and ten gold-premachined UCLA abutments were used for each systems. Each abutment was torqued to 30 N㎝ according to the manufacturer's instructions and detorque value was recorded. The detorque values were measured once more, after casting with gold alloy for UCLA abutment, and preparation for titanium abutments. Group means were calculated and compared using independent t-test and paired t-test (${\alpha}$=0.05). RESULTS: The results were as follows: 1. The detorque values between titanium abutments and UCLA-type abutments showed significant differences in internal octagonal implants (P<0.05), not in internal hexagonal implants (P>0.05). 2. In comparison of internal hexagonal and octagonal implants, the detorque values of titanium abutments had significant differences between two connection systems on the initial analysis (P<0.05), not on the second analysis (P>0.05) and the detorque values of UCLA-type abutments were not significantly different between two connection systems (P>0.05). 3. The detorque values of titanium abutments and UCLA-type abutments decreased significantly on the second analysis than the initial analysis in internal hexagonal implants (P<0.05), not in internal octagonal implants (P>0.05). CONCLUSION: Casting procedures of UCLA-type abutments had no significant effect on screw loosening in internal implant-abutment connection systems, and UCLA-type abutments showed higher detorque values than titanium abutments in internal octagonal implants.

The effect of additional etching and curing mechanism of composite resin on the dentin bond strength

  • Lee, In-Su;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.479-484
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS. Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at ${\times}20$ magnification. The data was analyzed using a one-way ANOVA and Scheffe's post-hoc test (${\alpha}$=.05). RESULTS. Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION. The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.

GFRP 보강근의 인장강도 분석을 위한 시험방법 비교 연구 (A Comparative Study on the Testing Methods for the Analysis of Tensile Strength of GERP Rebars)

  • 유영찬;박지선;유영준;박영환
    • 콘크리트학회논문집
    • /
    • 제18권3호
    • /
    • pp.303-312
    • /
    • 2006
  • 본 연구에서는 GFRP 보강근의 인장특성치 시험을 위한 그립 시스템의 적합성을 검증하기 위하여 캐나다 규준에서 제안하는 그립(CSA 그립), ASTM에서 제안하는 그립(ASTM 그립) 및 프리스트레싱 강연선의 정착에 일반적으로 사용되는 쐐기형 그립 등을 사용하여 GFRP 보강근에 대한 인장특성치 시험을 실시하였다. 또한, 현재 외국에서 상용화되고 있는 대표적인 2종류의 GFRP 보강근(나선형 GFRP 보강근, 모래분사형 GFRP 보강근) 및 국내에서 자체 제작한 원형 GFRP 보강근을 대상으로 하여 인장특성치 분석을 위한 시험을 실시하고 각각의 제안된 그립의 적용성 여부를 검토하였다. 본 시험에 사용된 시험편의 제작, 가력 및 측정장치의 설치 등은 CSA S806-02에서 제안하는 권고사항에 따라 실시하였다. 외국의 상용화된 GFRP 보강근에 대하여 그립의 종류를 달리하여 실시된 본 시험결과에 의하면, CSA 그립을 사용하여 시험된 GFRP 보강근의 인장강도가 가장 높은 값을 보이는 것으로 나타났다. 그러나 ASTM 그립을 사용한 시험편에서 관측되는 강도저하 현상은 CSA 그립을 사용한 시험체에 비하여 약 10% 미만인 것으로 관측되었다. 한편, CSA 그립은 제작공정이 까다로울 뿐만 아니라 재사용이 불가능하여 경제성 측면에서도 불리한 것으로 파악되었다. 따라서, 실용적인 측면에서 판단하면 GFRF 보강근의 인장시험에는 ASTM 그립이 적절할 것으로 판단된다.

개인용전기자극기 성능 및 안전성 평가 방법 연구 (A study on Evaluation Methods for Safety and Performance of Electrical Stimulations for Home Use)

  • 김산;장무영;황윤수;이기훈;허찬회;홍충만
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.187-202
    • /
    • 2013
  • 선진국의 고령사회 도래 및 웰빙 확산, 중국, 인도 등 후발 공업국의 급성장에 따라 최근 전자의료기기시장이 크게 확대 되고 있다. 이중 다소비 생활밀착형 전자의료기기중 하나인 개인용전기자극기는 통증완화, 재활치료, 근육운동 등의 목적으로 사용되는 전기자극기로써 가정에서 개인적으로 사용하는 만큼 그 안전성 및 성능 확보는 사용자의 측면에서 매우 중요하다고 볼 수 있다. 그러나 현재 개인용전기자극기에 대한 안전성과 유효성을 평가하는 가이드라인이 아직 마련되지 않은 실정이다. 따라서 본 연구에서는 국제수준에 부합하는 개인용전기자극기의 안전성과 성능을 평가하기위해 관련 국내외 규격을 검토하였고 시험항목, 기준 및 방법을 제안하였다. 또한 제안된 시험항목에 대한 시험검증을 통하여 최종적으로 국제 조화된 안전성 및 성능 평가 항목을 도출하였다. 본 연구 결과를 통하여 개인용전기자극기의 품질 및 안전성 향상을 도모함으로써 국내 전자의료기기산업의 국제 경쟁력 확보에 기여할 수 있을 것으로 기대된다.

초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상 (Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.19-33
    • /
    • 2008
  • 구조물에 고유한 진동수,모드형태 및 감쇠비 등과 같은 동적성능치를 추출하기 위하여 25층 및 42층 건물에 대하여 자연진동에 의한 동적계측실험을 수행하였다. 고려된 건물은 주요 횡하중 지지기구로서 코아벽체 혹은 전단벽체가 추가된 철근콘크리트건물이며, 입면 혹은 평면상으로 골조가 혼합된 구조형식을 나타낸다. 특히, 25층 건물은 측면에 위치한 코아벽체 이외에 상부로부터 내려오는 전단벽 구조가 4층 바닥이하에서 골조형식으로 전환되는 복잡한 구조이다. 이와 같은 이유 및 건물 주방향의 유사한 강성배치로 매우 근접하고 혼합된 모드형태가 예상되어 시스템판별 시 어려움이 예상된다. 현재까지 개발된 다양한 시스템판별법을 대상건물의 자연진동 실측기록에 적용하여 모달계수를 유도하였으며, 그 결과를 비교 분석하였다. 3개의 주파수영역 및 4개의 시간영역에 근거한 응답의존 시스템판별법이 고려되었다. 서로 다른 시스템판별법에 의하여 추출된 고유진동수 및 감쇠비는 대체로 상당한 일치를 보였으나, 모드형태는 사용된 방법에 따라 정도가 다르게 불일치를 나타냈다. 실험으로부터 추출한 성능치와 초기 유한요소해석 값을 비교해 본 결과 대상건물 모두 적어도 저차 3개의 고유진동수에서 2배 정도의 차이를 나타냈다. 실험과 해석결과의 일치를 위하여 몇몇 수동모델향상이 시도되었으며, 허용할 만한 결과를 획득하였다. 사용된 시스템판별법에 대하여 각자의 장, 단점에 대하여 기술하였으며, 본 연구와 같은 실제 대형구조물에 대하여 자동모델향상기법을 적용할 시 예상되는 문제점에 대하여 토의하였다.