• Title/Summary/Keyword: test procedures

Search Result 1,841, Processing Time 0.027 seconds

A Study of Comparison Test for Brake Disk Lining (KRRI-CARS) (제동디스크라이닝의 비교시험 연구(KRRI-CARS))

  • Hong Yong-Ki;Chung Jong-Duk;Kwon Sung-Tae;Wang Jing-Bo
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.363-368
    • /
    • 2003
  • The Inter-laboratory comparison test which is demanded on the authorized test of ISO 17025 is the program to guarantee the reliability for test results of test organization. In order to apply to the field of railway, brake disk lining as one of the railway components has been selected and the comparison test is executed for the purpose of guaranteeing the reciprocal reliability for the test result of both organizations and enlarging the substantial technique exchange of both nations by the standard establishment with test procedures and test programs from now on.

  • PDF

A Study on Overall Measurement System Development of HEMU-400X Performance Test (차세대고속열차 성능시험을 위한 종합계측시스템 개발 연구)

  • Lee, Young-Yeob;Ryu, Sang-Hyun;Kim, Bong-Rae;Kim, Kyung-Taek
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1118-1123
    • /
    • 2011
  • The introduction of high speed railway(KTX) in Korea after the Korean high speed train through the KTX-II of the development is being run is made. Thus the demand for the railway technology advances and high performance, Korean government promoted the development of the next-generation high speed train system(HEMU-400X). In addition to the production of train system essential element of the train through an on-line test is to evaluate the performance. Through the on-line test of the train in order to evaluate the performance test items should be selected first and need to the test procedures are required. In addition, an Overall Measuring System(OMS) to measure the performance of the train system should be established. In this study for the on-line test of the HEMU-400X test items was selected for detailed measurements and performance evaluation of a comprehensive and efficient trains to test an OMS for the development are discussed.

  • PDF

The Mach-scale Performance Test of Next-Generation Blade(NRSB- 1M/2M) (차세대 블레이드(NRSB-1M/2M)의 마하 스케일 성능시험)

  • Song, Geun-Ung;Kim, Jun-Ho;Kim, Seung-Ho
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.27-36
    • /
    • 2006
  • This paper describes the performance test procedures and results of NRSB-1M and NRSB-2M Not only aerodynamic performance test but also sound measurement test were performed for the small-scaled blades in the ground Total thrusts and torques of the rotor were measured using rotating balance for aerodynamic performance test. Sound pressure levels were measured using microphone in 1.64D distance for sound measurement test. Non-dimensionalized test data are compared and analyzed. Consequently, It was confirmed that NRSB-2 was better than NRSB-1.

  • PDF

Comparison and Analysis between the simulation and test result for Quality Assessment of Surge Protective Insulating Transformer. (서지방호용 절연변압기 성능시험관련 모의해석 및 시험결과와의 비교분석)

  • Choi Young-Ha;Kim Myung-Young;Lee Kang-Won;Ohn Jung-Ghun;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.519-522
    • /
    • 2003
  • 'KRS 6330-3256라' standard regulates performance test of insulating transformer for protecting the electronic interlock linkage equipment which is being done by test procedures and methods according to the standard. The balance/unbalance test evaluating the performance of transformer are applied by impulse voltage($l2/200{\mu}s$) but affected by many other factors. Therefore, the review about these is necessary to have the reliability and reappearance of test results. In this paper, we have simulated about several phenomenon appearing in real balance/unbalance test and compared simulated results with real ones. With the basis of these results, the influence to test result of inner and outer factors are investigated and analyzed and established the plan boosting the reliability and reappearance of test results.

  • PDF

Test procedures for the mean and variance simultaneously under normality

  • Park, Hyo-Il
    • Communications for Statistical Applications and Methods
    • /
    • v.23 no.6
    • /
    • pp.563-574
    • /
    • 2016
  • In this study, we propose several simultaneous tests to detect the difference between means and variances for the two-sample problem when the underlying distribution is normal. For this, we apply the likelihood ratio principle and propose a likelihood ratio test. We then consider a union-intersection test after identifying the likelihood statistic, a product of two individual likelihood statistics, to test the individual sub-null hypotheses. By noting that the union-intersection test can be considered a simultaneous test with combination function, also we propose simultaneous tests with combination functions to combine individual tests for each sub-null hypothesis. We apply the permutation principle to obtain the null distributions. We then provide an example to illustrate our proposed procedure and compare the efficiency among the proposed tests through a simulation study. We discuss some interesting features related to the simultaneous test as concluding remarks. Finally we show the expression of the likelihood ratio statistic with a product of two individual likelihood ratio statistics.

Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof (기와집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a Full Scale Model of Wood House with Tiled Roof (기와집 실물크기 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof (초가집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Huh, Young-Chul;Jeon, Bong-Hee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

International Symposium and Collaborative Study on Deep Cement Mixing, Okinawa 2009 (2009 오키나와 Deep Mixing 심포지엄 및 공동연구)

  • Jeong, Gyeong-Hwan;Shin, Min-Shik;Han, Gyeong-Tae;Lee, Jung-Hwa;Kim, Jae-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.972-978
    • /
    • 2008
  • Quality Assurance of Deep Mixing to fulfill the requirements of geotechnical design cannot be achieved only by the process control During production conducted by the deep mixing contractor but it should involve relevant activities that are carried out prior to, during and after the construction by all the parties involved in a deep mixing project. The requirement is different for different application, and hence, QA/QC method/procedure and verification technique may be different for different application. In order to maintain the high quality of deep mixing work in the global market, it is necessary to conduct a research project, such as investigation of illustrations, the variety of existing QA/QC methods/procedures, the correlation between the outcomes of different QA/QC methods. In these reason, it has been held the international meeting to discuss them, in that kind of activities in 2009 it will be held Symposium. Also Collaborative study for QA/QC is on goin, and conduction by all participated members. The subject for collaborative study are, task 1 : investigation of laboratory tests procedures, task 2 : comparing of different laboratory tests procedures, task 3 : QA/QC method/procedures, task 4 : integrated Task1 ~task 3. The discussion of the results in all task will be held in the Symposium separately. In this paper, it was presented four tasks. Also the results in task 1 and 2 conducting domestically until now, such as investigation of laboratory test procedures, effect on the unconfined compressive strength by aging temperature and by delayed time.

  • PDF

Pain Response to Procedural Pain in Premature Infants (미숙아의 시술 관련 통증 반응)

  • Kim, Jung-Sook;Lee, Eun-Jung;Ham, Eun-Ha;Kim, Ji-Hyun;Yi, Young-Hee
    • Child Health Nursing Research
    • /
    • v.16 no.4
    • /
    • pp.352-359
    • /
    • 2010
  • Purpose: To explore premature infants' pain response to routine procedures in the neonatal intensive care unit (NICU). Methods: The participants were 56 preterm infants who showed 149 pain responses to 8 high frequency routine procedures which were evaluated using the Premature Infant Pain Scale (PIPS). Videotaped recording was used for data collection. Data were analyzed with descriptive analysis, paired t-test, and Pearson's correlation coefficient. Results: PIPS scores for each procedure were as follows; for removal of central catheter dressing, 6.17 (2.04), venous sampling, 6.12 (2.87), intramuscular injection, 6.05 (2.38), insertion of a peripheral line, 5.38 (2.16), insertion of feeding tube, 4.40 (1.34), heel stick, 4.33 (1.23), insertion of central line, 4.00 (2.12), and endotracheal suctioning, 2.90 (1.25). PIPS score was negatively correlated with gestational age (r=-.218, p=.007) and birth weight (r=-.249, p=.002) among general characteristics of the infants. Conclusion: The majority of 8 routine procedures were found to be painful for premature infants in the NICU. Therefore, adequate pain management related to procedures should be provided to premature infant in the NICU.