• Title/Summary/Keyword: test power

Search Result 10,130, Processing Time 0.037 seconds

More Powerful Test for Normality Based on the Normalized Sample Lorenz Curve (NORMALIZED SAMPLE LORENZ CURVE를 이용한 검정력이 높은 정규성 검정)

  • 강석복;조영석
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.415-421
    • /
    • 2002
  • Because most common assumption is normality in statistical analysis, testing normality is very important. We propose a new plot and test statistic to test for normality based on the modified Lorenz curve that is proved to be a powerful tool to measure the income inequality within a population of income receivers. We also compare the proposed test statistics with the W test (Shapiro and Wilk (1965)), TL test (Kang and Cho (1999)) in terms of the power of test through by Monte Carlo method. The proposed test is more usually powerful than the other tests except some case.

Tests to Detect Changes in Micro-Flora Composition;

  • Kim, Donguk;Yang, Mark C.K.
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.1
    • /
    • pp.211-224
    • /
    • 2003
  • Good's lambda test, a permutation test used to detect the changes of microorganism composition under two pathological conditions, has been quite popular for studying the micro-flora responsible for periodontal disease. A vast number of different micro-flora in the mouth renders the traditional chi-square test inapplicable. The main purpose of this paper is to evaluate the power of this test so that the sample size can be determined at the design stage. The robustness of this test and its comparison to two other intuitive tests are also presented. It is found that a permutation test based on likelihood ratio is more powerful than the lambda test in our simulated cases.

Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine (스팀터빈의 공력성능 평가를 위한 공기 상사실험)

  • Lim, Byeung-Jun;Lee, Eun-Seok;Lee, Ik-Hyoung;Kim, Young-Sang;Kwon, Gee-Bum
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.73-79
    • /
    • 2003
  • The steam turbine efficiency is an important factor in power plant. Accurate evaluation of steam turbine performance is essential. However, it is not easy to evaluate the steam turbine performance due to its high temperature and high pressure circumstance. Therefore most steam turbine performance tests were conducted by air similarity test. This paper described a test program for air similarity test of steam turbine at Korea Aerospace Research Institute. A test facility has been designed and built to evaluate aerodynamic performance of turbines. The test facility consists of air supply system, single stage test section, power absorption system, instrumentation and auxiliary system. For evaluation of steam turbine performance, the test of single stage axial turbine air similarity performance was conducted and uncertainty analysis was performed.

  • PDF

Development of High Intensity Progressive Wave Tube (고에너지 음향환경시험 튜브 개발)

  • K.Kim, Young-Key;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Im, Jong-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.962-965
    • /
    • 2005
  • A high intensity progressive wave tube is installed at Korea Aerospace Research Institute (KARI) for acoustic environmental tests. The test facility has 700 mm x 800 mm cross-sectional area, and provides acoustic environment of 165 dB over the frequency range of $25Hz{\sim}10,000Hz$. The facility consists of a 6 m long acoustic wave tube, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of the facility and power generation systems are controlled to meet the requirement of the test. The shape and length of the tube has been designed by using the size of test objects and the wave propagation characteristics of the tube. The capacity of acoustic power generation systems is determined by the energy conversion of acoustic wave and the efficiency of acoustic modulators. Moreover, the paper introduces test run results of the tube. Overall of 163dB has been generated by using the test facility.

  • PDF

The Study on Image Sensitivity Evaluation For Digital Radiography Image (디지털 방사선 투과영상의 식별도 평가 연구)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification (스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석)

  • Ahn, Sang-Kyu;Kim, Seung-Jong;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Wong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

Spectral Electromyographic Fatigue Analysis of Back Muscles in Healthy Adult Men and Women During Sorensen Test (근전도를 이용한 Sorensen 검사시 성인남녀 등 근육의 근피로도 분석)

  • Lee, Mi-Seon;Kim, Tae-Young
    • Physical Therapy Korea
    • /
    • v.5 no.3
    • /
    • pp.63-71
    • /
    • 1998
  • Trunk holding test (Sorensen test) appear to have more value than strength test in prediction the occurrence of low back pain. Electromyographic activity of trunk extensor muscles during these test may provide clues to the etiology of neuromuscular-based low back pain. This study investigated the difference in back muscle endurance between healthy adult men and women using surface electromyographic (EMG) power spectral analysis. Thirty hea1thy subjects (15 men and 15 women) performed an unsupported trunk holding test for 60 seconds. Recording surface electrodes were placed over the erector spinae medially and laterally at vertebral levels of $L_1$ and $L_5$. Slope of total frequency was evaluated using the MP100WSW Fast Fourier Transform spectrum analysis program. The slopes of all indices of back muscle fatigue, except right $L_5$, were significantly steeper in men than in women (p<0.05). Our results indicated that the trunk holding test using EMG power spectral analysis of erector spinae muscles is useful for the evaluation of fatigue rate of these muscles. Our results also showed a higher muscle endurance in healthy adult women than in men.

  • PDF

The analysis of electrical characteristics with Micro-crack in PV module (Micro-cracks에 의한 PV 모듈의 전기적 특성 분석)

  • Song, Young-Hun;Ji, Yand-Geun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

A study on the relationship of lumbar extensor muscle power and static spinal loaded test for old female patients with lumbar degenerative kyphosis (요추후만증을 가진 여자 노인 환자의 정적 척추부하 검사와 허리신전근력과의 관계)

  • Kim, Sung-Ho;Kim, Myung-Joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.29-38
    • /
    • 2003
  • The purpose of this study was to investigate relationship of lumbar extensor muscle power & spinal column curve for old female patients with LDK(Lumbar degenerative kyphosis). Subjects were composed of 37 old female with LDK. The subjects were tested in their spinal segment movement and spinal column curve with Spinal-$Mouse^{\leq}$ in $1^{st}$ loaded test and $2^{nd}$ loaded test and then tested lumbar extensor muscle power with $Medx^{\leq}$ lumbar extension machine. The results of this study, were as follow; There were statistically significant difference $1^{st}$ loaded test and $2^{nd}$ loaded test in upright position increase spinal column forwardly(p<0.01) and decrease lumbar lordosis angle(p<0.01), but no statistically significant difference $1^{st}$ loaded test and $2^{nd}$ loaded test thoracic and hip & sacrum curve angle. Their lumbar extensor muscle poser is very weakness, 61.4% of normal people.

  • PDF

Investigation on the Commercialization Issues of Resistive Type Superconducting Fault Current Limiters for Electric Networks

  • Park, Tae-Gun;Lee, Sang-Hwa;Lee, Bang-Wook
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Among the various types of fault current limiters, superconducting fault current limiters could be the most preferable choice for high voltage electric power systems owing to the remarkable current limiting characteristics of superconductors. But, there have been no commercial superconducting fault current limiters which were installed into actual electric power systems until these days due to some remained technical and economical problems. Thus, in order to promote the development and application of the superconducting fault current limiters into real field, it is essential to understand the power utilities’ requirements for their networks and also suitable test method and some specifications should be prepared. This paper focuses on the matters of test requirements and standardization issues that should be prepared for commercialization of superconducting fault current limiters. The unique current limiting characteristics of superconducting fault current limiters were investigated and related other standards including circuit breakers, transformers, reactors, power fuse, and fused circuit breakers were compared to setup the basis of novel specification of superconducting fault current limiters. Furthermore, required essential test procedures for superconducting fault current limiters were suggested.

  • PDF