• 제목/요약/키워드: test power

검색결과 10,054건 처리시간 0.047초

A Study on Leaching Characteristics of Paraffin Waste Form Including Boric Acid

  • Kim, Ju-Youl;Chung, Chang-Hyun;Park, Heui-Joo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.10-16
    • /
    • 2000
  • Preliminary experiment was peformed to investigate the leaching characteristics of paraffin waste forms that had been recently generated in large quantities at domestic nuclear power plants. At first, waste simulants whose compositions were different in mixing ratio of paraffin to boric acid were prepared. Their compressive strengths were measured and ninety-day leaching test of specimen including cobalt was carried out according to ANSI/ANS-16.1 test procedure. Water immersion test was also conducted keeping pace with leaching test and the weight change and the compressive strength of specimen were observed after ninety days. The compressive strength of waste form exhibited 666 psi (4.53 MPa) in the case where mixing ratio of boric acid to paraffin was 78/22, which was adopted in concentrate waste drying system of domestic nuclear power plants. The leaching test resulted in about 50% of the cumulative fraction leached for boric acid and cobalt, respectively. The specific gravity of waste form was 0.87 [g/g]whose value was less than that of water because the weight loss of about 39% occurred after the water immersion test of ninety days. It was also observed that the waste form which had undergone ninety-day water immersion test exhibited the compressive strength of 203 psi (1.38 MPa).

  • PDF

On-line 발전기 주파수응답시험 개발 및 적용에 관한 연구 (Study on Development & Implementation of Online Generator Frequency Response Test)

  • 오창수;곽월환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.48-49
    • /
    • 2006
  • Recently, Importance of Generator's Active/Reactive Power Control Capability is highly emphasized for prevention of Large Blackout. Especially, Generator's frequency Response Capability is important to the Power System Frequency Stability. This paper deals with the Development & Implementation of Each Generator Frequency Response Capability Test via the Injection of Artificial Frequency to the Online Generator. Actual On-line Generator's frequency Response Test was successfully implemented to 13 Generator having various fuel source.

  • PDF

원전 벽체구조물의 철근모듈화 적용을 위한 Mock-Up 실험연구 (The Mock-Up Test for Applying Rebar Modularization to the Wall of Nuclear Power Plant)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.7-8
    • /
    • 2016
  • We are developing the technology for applying the Rebar Modularization Method to the Nuclear Power Plant Structures. To achieve this, we had developed the elementary technology for applying this method to Nuclear Power Plant Structures efficiently and performed the Mock-Up Test by using the developed elementary technology. By analysing this test result, we deduced the problems and found solutions to solve them.

  • PDF

The correlation between the physical power of golf players and the Titleist Performance Institute Level 1 test

  • Kim, Jaeeun;Yim, Jongeun;Do, Kwangsun
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권1호
    • /
    • pp.13-17
    • /
    • 2018
  • Objective: This was a correlation study for predicting the power to improve the distance of golf players and developing an effective power program. Design: Cross-sectional study. Methods: The subjects of this study were 24 healthy males and females in their 20s and 30s who were golf athletes living in Seoul and Gyeonggi-do. In the Titleist Performance Institute (TPI) Level 1 test, the twelve swing characteristics include components of stability, mobility, body conditioning ability, and balance. The power test consisted of a vertical jump (VJ) in order to examine the power of the lower body, the seated chest pass (SCP) was used to examine upper body power, and the sit up and throw (SUAT) was used to examine the power of the upper body and core for the TPI Level 2 test. Results: The results of this study showed that the 90/90 was correlated with VJ, SUAT, and SCP scores (p<0.05). Single leg stance was correlated with VJ, SUAT, over head deep squat, and bridge with leg extension were correlated with VJ (p<0.05). The toe touch was correlated with SUAT results (p<0.05). Conclusions: The results of this study showed that the TPI Level 1 test and power test were correlated with the performance of the golf players. Future studies have shown that fitness program development and further research are needed.

154kV 전력용 변압기의 온도분포에 관한 연구 (The Study on the Temperature Distribution for 154kV Power Transformers)

  • 우정욱;구교선;곽주식;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

Scan Cell Grouping Algorithm for Low Power Design

  • Kim, In-Soo;Min, Hyoung-Bok
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.130-134
    • /
    • 2008
  • The increasing size of very large scale integration (VLSI) circuits, high transistor density, and popularity of low-power circuit and system design are making the minimization of power dissipation an important issue in VLSI design. Test Power dissipation is exceedingly high in scan based environments wherein scan chain transitions during the shift of test data further reflect into significant levels of circuit switching unnecessarily. Scan chain or cell modification lead to reduced dissipations of power. The ETC algorithm of previous work has weak points. Taking all of this into account, we therefore propose a new algorithm. Its name is RE_ETC. The proposed modifications in the scan chain consist of Exclusive-OR gate insertion and scan cell reordering, leading to significant power reductions with absolutely no area or performance penalty whatsoever. Experimental results confirm the considerable reductions in scan chain transitions. We show that modified scan cell has the improvement of test efficiency and power dissipations.

리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험 (The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System)

  • 이학주;채우규;박중성;손진만;최은식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

PSCAD/RTDS에서 345kV 변압기 모델링을 통한 변압기용 보호계전기의 동특성 시험 (Dynamic Performance Test of Power Transformer Protective Relay using 345kV Transformer Modelling of PSCAD/RTDS)

  • 권기백;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.120-123
    • /
    • 2005
  • This paper, for the establishment of power system models and test procedures for the dynamic performance test of transformer protective relay, presents power system model, environment establishement between RTDS and protective relay, and the dynamic performance test generated internal fault or external fault.

  • PDF

보호계전기 특성시험기술의 시험항목 변화 (Testing Items Change on Characteristics of Protective relays)

  • 장병태;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.161-162
    • /
    • 2008
  • The steady state performance test for the digital protective relay using general relay test equipment has been main test methods. Because of the development of advanced power system testing equipments, dynamic performance test has been carried out additionally using a digital simulator such as RTDS(Real Time Digital Simulator). For the case of newly adopted digital protective relay with IEC 61850 and network, performance testing items need supplementing. This report displays testing items change according to newly protective relay.

  • PDF

발전설비 고온부에서 사용되는 스터드 볼트의 교체기준 설명 (Establishment of Replacement Criteria for Stud Bolts using on High Temperature in the Power Plants)

  • 정남용;김문영
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.279-286
    • /
    • 2000
  • The stud bolts tend to degrade faster by high temperature(over 45$0^{\circ}C$). Therefore, replacement cycle inspection of stud bolts were carried out various method such as ultrasonic test(UT), magnetic test(MT), wobble test, visual test and hardness test. Especially, wobble test method has been applied to determine replacement evaluation criteria of stud bolt after long time operation. We applied three different methods on the three site and the obtained data are compared with the results from the evaluation methods. From the results, the replacement criteria for stud bolts under high temperature in power plants are proposed.

  • PDF