• Title/Summary/Keyword: test circuit

Search Result 1,833, Processing Time 0.032 seconds

Re-ignition System using Vacuum Triggered Gap-switch for Synthetic Breaking Test

  • Park Seung-Jae;Suh Yoon-Taek;Kim Dae-Won;Kim Maeng-Hyun;Song Won-Pyo;Koh Hee-Seog
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.145-151
    • /
    • 2005
  • The synthetic breaking test method was developed to evaluate the breaking performance of ultra high-voltage circuit breaker and made up of two independent circuits; current source circuit and voltage source circuit. In application of this test method, it is necessary to extend the arc of the test breaker. So, the new re-ignition system using VTGS (Vacuum Triggered Gap-Switch) was constructed to improve the efficiency and reliability of this test. In this re-ignition system, VTGS operates in high vacuum state of $5{\time}10^{17}$torr and control system consists of the triggering device and the air M-G (Motor-Generator). This re-ignition system showed the operating characteristics, such as delay time ($t_d$) and jitter time ($t_j$ not exceeding 5us and 1us respectively, and had the operating voltage of $25\~150kVdc$ at the gap distance of 24mm.

Short Circuit Electromagnetic Force Prediction by Coupled Electromagnetic-Mechanical Field Analysis of Dry-Type Transformer (전자계-기계계 결합해석에 의한 건식변압기의 단락강도 예측)

  • Ahn, Hyun-Mo;Hahn, Sung-Chin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.301-308
    • /
    • 2011
  • This paper deals with the coupled electromagnetic-mechanical field analysis for short-circuit electromagnetic force of the dry-type transformer. The short-circuit currents are calculated using external circuit in accordance with short-circuit test equipment. According to short-circuit current, the generated magnetic leakage flux density in dry-type transformer model is calculated by finite element method. The radially-directed electromagnetic forces in windings are calculated using electromagnetic field analysis and then axially-directed electromagnetic forces in windings are calculated using electromagnetic-mechanical field analysis. The calculated axially-directed electromagnetic forces in high voltage winding are compared to those of measured ones and showed good agreement with experimental results.

Equivalent Circuit Composition of a Linear Induction Motor (선형유도전동기의 등가회로 구성 - LIM의 T형 등가회로 산정을 위한 구속시험 -)

  • Jang, S.M.;Lee, H.G.;Park, Y.T.;Kim, B.S.;Jeong, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.47-49
    • /
    • 1996
  • The equivalent circuit of LIM is generally composed as the same that of rotary induction motor. However it is very difficult to move the LIM at synchronous velocity for open-secondary circuit test. The resistance representing the core losses in the primary core can not be ignored because the air-gap of LIM is larger than that of rotary induction motor. In this paper, the T-type equivalent circuit of a LIM with the core loss resistance is chosen using static zero slip test and theoritical analysis.

  • PDF

Estimating the Effect of Overvoltage Results from Excitation Current Chopping in Short-circuit Transformer (여자전류 재단에 따른 단락 시험용 변압기의 절연영향 평가)

  • Oh, Seung-Ryle;Park, Ji-Hun;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.78-80
    • /
    • 2007
  • The residual flux in transformer's iron cores leads to a distortion of short-circuit current occasionally. And some considerable distortion may have effect on the validation of the test results. To avoid the substantial distortion, a suitable pretest is performed before the actual test. In case of applying this method there must be excessive overvoltage due to switching of an unloaded transformer and chopping of an excitation current. The purpose of this paper is estimate that the effect of the overvoltage results from this phenomenon on insulation performance of short-circuit transformer.

  • PDF

Development of device for the degree of freshness of wet fish (어육신선도 측정장치의 개발)

  • 유휘룡;이남걸;신민생;조영제;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.272-275
    • /
    • 1992
  • Recently, the digital circuit technique has had great success and gained importance in all industries. For the measurement of degree of freshness of plant and animal's tissue, many devices has been developed. But it's data was inaccurate and it had difficulty in making database because it was depend on analog circuit technique. The purpose of this paper is the development of a device based on digital circuit for measurement of freshness degree of wet fish such that its accuracy is very trustworthy and it can be measured in a short time. The device is developed by using micro-computer with some interface modules of A-D/D-A converter and digital circuit with IC modules and its effectiveness has been evaluated through two experimental results of electrical Q-value test and chemical K-value test.

  • PDF

The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Underground Transmission Cable (송전케이블 삼상단락 실증시험을 통한 전자력 대책방안 연구)

  • Kang, Ji-Won;Park, Hung-Sok;Yoon, Jong-Keon;Kim, Yang-Sang;Hong, Dong-Suk;Chang, Woo-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2342-2348
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, the interaction of electromagnetic force by fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

The Optimal Circuit Condition Selection for Cable Charging Current Test by IEC60265-1 (IEC60265-1에 의한 케이블 충전전류 시험을 위한 최적 회로 조건 선정)

  • Kim, K.D.;Hur, Y.S.;Yun, J.H.;Lee, H.C.;Ham, G.H.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.264-266
    • /
    • 2001
  • We must consider resistance capacitance and their circuit connection condition for cable charging current test by IEC60265-1. According to their values and circuits, the ratio of applied voltage and transient recovery voltage are much different. This paper is convinced of TRV waves and proposes the optical circuit required at the standard via the simulation of all circuit conditions.

  • PDF

300kV DC Charging system for Synthetic Testing Facility (합성 차단 시험용 DC300kV 충전장치 개발)

  • Rim, G.H.;Choi, Y.W.;Park, J.M.;Park, K.Y.;Lee, W.Y.;Chung, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1354-1356
    • /
    • 2000
  • This paper deals with a 300kV dc charging system to be used ?s a voltage source in a circuit breaker synthetic short-circuit-test facility. Cockcroft-walton circuit is used to step up the rectified voltage from a single phase transformer of which primary winding is hooked up to an ac220 wall plug. Two systems with the same ratings have been designed and manufactured. The two system have been made of different supporting structure with different insulating materials. The paper describes a couple of charging schemes, system configurations and the synthetic test circuit in which the developed system is to be used.

  • PDF

Breaking test of UHV circuit breaker by ANSI/IEEE standard (ANSI/IEEE를 적용한 초고압 차단기의 차단시험)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

Controlling the Residual Flux in Transformer to Prevent the Distortion of Short-circuit Current (단락 전류 왜형방지를 위한 변압기 잔류자속제어)

  • Oh, Seung-Ryle;Park, Ji-Hun;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.237-239
    • /
    • 2006
  • The residual flux(${\psi}_r$) in transformer's iron cores cause the distortion of short-circuit current occasionally. And some considerable distortion effect on the validation of test results. To prevent this situation, there needs some suitable control of residual flux through the pretest. This paper deals with the how to control the residual flux in pretest and the comparison between the two test results which were obtained by different test method.

  • PDF