• 제목/요약/키워드: test beam

검색결과 2,905건 처리시간 0.028초

시뮬레이션과 실험을 통한 전개하는 보의 횡 방향 진동 분석 (Transverse Vibration Analysis of the Deploying Beam by Simulation and Experiment)

  • 김재원;주극비;정진태
    • 한국소음진동공학회논문집
    • /
    • 제25권12호
    • /
    • pp.866-873
    • /
    • 2015
  • The transverse vibration of the deploying beam from rigid hub was analyzed by simulation and experiment. The linear governing equation of the deploying beam was obtained using the Euler-Bernoulli beam theory. To discretize the governing equation, the Galerkin method was used. After transforming the governing equation into the weak form, the weak form was discretized. The discretized equation was expressed by the matrix-vector form, and then the Newmark method was applied to simulate. To consider the damping effect of the beam, we conducted the modal test with various beam length. The mass proportional damping was selected by the relation of the first and second damping ratio. The proportional damping coefficient was calculated using the acquired natural frequency and damping ratio through the modal test. The experiment was set up to measure the transverse vibration of the deploying beam. The fixed beam at the carriage of the linear actuator was moved by moving the carriage. The transverse vibration of the deploying beam was observed by the Eulerian description near the hub. The deploying or retraction motion of the beam had the constant velocity and the velocity profile with acceleration and deceleration. We compared the transverse vibration results by the simulation and experiment. The observed response by the Eulerian description were analyzed.

Shear behavior and shear capacity prediction of precast concrete-encased steel beams

  • Yu, Yunlong;Yang, Yong;Xue, Yicong;Liu, Yaping
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.261-272
    • /
    • 2020
  • A novel precast concrete-encased steel composite beam, which can be abbreviated as PCES beam, is introduced in this paper. In order to investigate the shear behavior of this PCES beam, a test of eight full-scale PCES beam specimens was carried out, in which the specimens were subjected to positive bending moment or negative bending moment, respectively. The factors which affected the shear behavior, such as the shear span-to-depth aspect ratio and the existence of concrete flange, were taken into account. During the test, the load-deflection curves of the test specimens were recorded, while the crack propagation patterns together with the failure patterns were observed as well. From the test results, it could be concluded that the tested PCES beams could all exhibit ductile shear behavior, and the innovative shear connectors between the precast concrete and cast-in-place concrete, namely the precast concrete transverse diaphragms, were verified to be effective. Then, based on the shear deformation compatibility, a theoretical model for predicting the shear capacity of the proposed PCES beams was put forward and verified to be valid with the good agreement of the shear capacities calculated using the proposed method and those from the experiments. Finally, in order to facilitate the preliminary design in practical applications, a simplified calculation method for predicting the shear capacity of the proposed PCES beams was also put forward and validated using available test results.

보 플랜지 절취형 (RBS) 철골 모멘트 접합부의 균형패널존 강도 (A Balanced Panel Zone Strength Criterion for Reduced Beam Section Steel Moment Connections)

  • 이철호;김재훈;전상우;김진호
    • 한국강구조학회 논문집
    • /
    • 제18권1호
    • /
    • pp.59-69
    • /
    • 2006
  • 본 연구에서는 보 플랜지 절취형 (Reduced Beam Section, RBS) 철골모멘트접합부의 실험결과를 기초로 패널존의 적정강도를 제시하고자 하였다. RBS 충분한 실험자료가 보고 되어 있음에도 불구하고, 패널존의 적정강도 범위가 아직 제시된 바가 없다. 본 연구 및 다른 연구자의 실험결과에 의할 때, 패널존은 보 플랜지 그루브 용접부에 유해한 영향을 미치지 않고 0.01 radian의 소성회전각을 무난하게 발휘할 수 있음이 확인되었다. 또한 이 정도 크기의 패널존 소성변형을 허용하면 강한 패널존 시험체에 비해 횡비틀림 좌굴의 진폭이 절반 정도로 감소하였다. 이러한 실험적 관측을 토대로 RBS접합부의 소성변형능력을 향상시킴과 동시에 보의 소성힌지에 발생하는 좌굴의 크기를 줄일 수 있는 균형 패널존에 대한 강도 기준을 제안하였다.

웨브를 볼트로 접합한 보 플랜지 절취형(RBS) 철골모멘트접합부의 내진설계 및 성능평가 (Seismic Design and Testing of Reduced Beam Section Steel Moment Connections with Bolted Web Attachment)

  • 이철호;김재훈
    • 한국강구조학회 논문집
    • /
    • 제17권6호통권79호
    • /
    • pp.689-697
    • /
    • 2005
  • 보 플랜지 절취형 (Reduced Beam Section, RBS) 내진 철골모멘트접합부의 최근 실험결과를 살펴보면, 보 웨브를 볼트 접합한 시험체는 보 웨브를 용접한 시험체에 비해 조기에 스캘럽에서 취성파단이 발생하는 열등한 내진성능을 나타냈다. 과거 여러 연구자들이 수행한 실험 결과 및 본 연구의 수치해석 결과를 종합해 볼 때, 이러한 접합부의 조기 취성파괴는 고전 휨이론과 매우 다른 응력전달 메카니즘에서 기인하는 웨브 볼트의 슬립, 그리고 재료의 인성이 가장 낮은 스캘럽 부근의 응력집중과 밀접한 관련이 있는 것으로 분석된다. 본 연구에서는 실험 및 해석결과를 바탕으로 RBS 접합부의 실제 응력전달경로에 부합되는 새로운 보 웨브 볼트 설계법 및 개선된 상세를 제시하고 실물대 실험을 통하여 방안의 타당성을 입증하였다.

강재의 단면형상에 따른 내화피복두께 산정 연구 (Study on the Determination of Fire Protection Thickness based on Section Factor)

  • 정청운;지남용;권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

철근콘크리트 기둥과 철골보의 접합부 개발 및 지압성능에 관한 시험적 연구 (A Study on the Development and Test on Bearing Resistance of R/C Column-Steel Girder Connection)

  • 최광호;이세웅;김재순;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.515-520
    • /
    • 1997
  • This research is aimed at the development of the composite beam-column connection system by which the steel beam can be connected to the R/C column with smooth stress transfer. As the first step of the structural performance tests of the system, bearing resistance test has been carried out for actual size specimen. From the test, the connection system has been proved to take good bonding and stress transfer to the surrounding concrete with negligible relative displacements.

  • PDF

반복하중하의 탄소섬유시트 보강보의 거동에 관한 연구 (A study on the behavior of beam strengthened with CFS under repeated loading)

  • 박정용;정진환;김성도;조백순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.627-630
    • /
    • 2004
  • This paper investigates a study on the bending behavior of beam strengthened with CFS under repeated loading. The test specimen consisted of 20cm in width, 40cm in depth, and 15cm in CFS width. We find the strength decrease under repeated loading test comparing with the monotonic incremental loading test.

  • PDF

근전계 빔 집속 시험 기법을 활용한 평면위상배열레이다 시스템 복사 및 빔 조향 특성 검증 (Verification of Radiation and Beam-Steering Characteristics for Planar-Phased Array Radars Using Near-Field Beam Focusing)

  • 김영완;이재민;정채현;박종국;이유리;김종필;김선주
    • 한국전자파학회논문지
    • /
    • 제30권2호
    • /
    • pp.160-168
    • /
    • 2019
  • 본 논문에서는 근전계 빔 집속(near-field beam focusing: NFBF) 시험을 활용한 평면위상배열레이다 시스템의 성능 검증 방안을 제시하고 결과의 유효성을 확인하였다. 제시한 시험 기법은 안테나 개구면 크기 두 배 거리의 근전계 영역에서 레이다 시스템을 검증하는 방안으로 야외가 아닌 전자파 무반향실 내에서 원전계 성능 시험과 동일하게 레이다 시스템을 검증할 수 있었다. 이를 위해 근전계 에너지를 사용한 빔 집속 시험의 시험 구성도 및 검증 절차에 대하여 기술하였다. 또한 빔 조향된 근전계 빔 집속 시험에 대한 수학적인 검증을 통해 개별채널의 추가적인 위상 보상값을 수치화하였다. 이론적인 검증에 기반하여 실제 근전계 빔 집속 시험을 수행하였고 이상적인 결과와의 비교를 통해 시험 방법의 유효성을 확인하였다.

9%Ni 강의 전자빔 용접성에 관한 연구 (I) - 전자빔 특성과 용입 - (A Study on the Electrom Beam Weldability of 9%Ni Steel (I) - Penetration and Electron Beam Characteristics -)

  • 김숙환;강정윤
    • Journal of Welding and Joining
    • /
    • 제15권3호
    • /
    • pp.79-87
    • /
    • 1997
  • This study was performed to evaluate basic characteristics of electron beam welding process for a 9% Ni steel plate. The principal welding process parameters, such as working distance, accelerating voltage, beam current and welding speed were investigated. The AB (Arata Beam) test method was also applied to characterize beam size and energy density of the electron beam welding process. The electron beam size was found to decrease with the increase of accelerating voltage and the decrease of working distance. So, in case of high voltage (150kV), spot size and energy density of electron beam were revealed to be 0.9mm and $6.5\times10^5W/\textrm{cm}^2$ respectively. The accelerating voltage among the welding parameters was found to be the most important factor governing the penetration depth. When the accelerating voltage of electron beam was low ($\leq$90kV), beam current and welding speed did not affect on the penetration depth significantly. However, in case of high voltage ($\geq$120kV), the depth of penetration increased very sensitively with the increase of beam current and the decrease of welding speed.

  • PDF

외부 긴장된 H형 보의 휨거동 특성 (Flexural Behavior of External Prestressed H-Beam)

  • 양동석;임상훈;박선규
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.79-85
    • /
    • 2002
  • 본 연구에서는 기존에 사용된 H-Beam 교량을 편향부와 외부 긴장력을 도입하여 보강효과에 의하여 지간을 증가시킬 수 있고 단면을 축소할 수 있다는 근거를 제시하였고, 유연도법을 이용하여 편향부의 효과에 의한 추가 긴장량을 산정하였다. 또한, 실험변수(긴장량, Tendon의 개수, 편향부의 유 무)에 의해서 표준실험체(기존 H-Beam)와 외부 긴장된 H-Beam 등 5개의 실험체를 제작하여 휨 실험을 실시하여 외부 긴장된 H-Beam의 역학적 거동을 연구하였다. 특히, 보강효과 및 편향부의 효과를 실험적으로 검증하였다.