• 제목/요약/키워드: termination condition

검색결과 79건 처리시간 0.022초

An Inclusive Method for Application of Combat Termination Rules (전투종료규칙의 포괄적 적용방법)

  • 백자성;하석태
    • Journal of the military operations research society of Korea
    • /
    • 제26권1호
    • /
    • pp.125-144
    • /
    • 2000
  • Occasionally, there are combat situations which one or both forces can´t terminate the combat using selected combat termination rule according to given relationship between ratio of attrition rate coefficient and threshold values. In this study, we classify the situations that one or both forces can´t terminate the combat with selected combat termination rule into four conditions. Condition${\circled1}$ is the situation which both Blue and Red can terminate the combat using all selected combat termination rules. condition${\circled2}$ and condition${\circled3}$ are those which neither Blue or Red can terminate the combat using selected proportional decision rule, and condition${\circled4}$ is that which both Blue and Red can´t terminate the combat using selected proportional decision rule. We analyze the effect of combat termination rules on parity number, final combat power, and combat durations for each conditions. Also, we propose the method to apply the analyzed effect of combat termination rules to combat analysis.

  • PDF

Effects of Surface Termination on Directional Emission from Photonic Crystal Waveguides

  • Chung, K.B.
    • Journal of the Optical Society of Korea
    • /
    • 제12권1호
    • /
    • pp.13-18
    • /
    • 2008
  • We numerically investigate by the finite-difference time-domain method the effects of surface termination on directional emission exiting a photonic crystal waveguide. The directed power and far-field beam profile for the original proposal [E. Moreno et al., Phys. Rev. B 69, 121402 (2004)] and its enhancement [S. K. Morrison et al., Appl. Phys. Lett. 86, 081110 (2005)] are computed for different values of some important parameters. We find another surface termination condition with a positive surface displacement in the structure of the original proposal which has a negative surface displacement. Our surface termination is more effective than the original structure, and nearly as effective as the termination for the enhancement, for directional emission. Besides, our termination is simpler than that for the enhancement. We confirm the effectiveness of directional emission from our termination in its far-field beam profile, radiation intensity distribution, and additionally the wave-vector space representation by the Fourier analysis.

A Study On Effects of The Termination Conditions on Crosstalk in The A/D Converter Circuit (A/D 변환기 회로에서 터미네이션 임피던스의 crosstalk에 대한 영향 분석)

  • Lim, Han-Sang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • 제47권2호
    • /
    • pp.35-42
    • /
    • 2010
  • In this study, crosstalk between dominant interconnect pairs in an A/D converter circuit is analyzed in frequency domain and effects of termination conditions on crosstalk are described, based on the practical circuit conditions. An A/D converter circuit is a mixed circuit where both clean and noisy signals coexist such that the circuit probably suffers from distortion by crosstalk. An analog input signal and the reference voltage signal, which dominate the overall conversion performance of the A/D converter circuit, are ready to be distorted by crosstalk and include specific termination conditions, such as non-matching and capacitive termination, respectively. Thus, this study presents the model of crosstalk considering impedance mismatch at both ends and analyzes effects of the practical termination conditions in the analog input and the reference voltage interconnects on crosstalk. A typical circuit configuration of the two interconnects is described and crosstalk including near-end and far-end termination impedances is modeled. Effects of the near-end impedance mismatch in the analog input interconnect and the far-end capacitive termination in the reference voltage interconnect are estimated in the frequency domain by using the model of crosstalk and experiments are performed to confirm the estimated results. Microstrip lines are used as interconnects, involving the increase of loss in high frequencies.

A Study on Early Termination Payment Option of BTO PPI Projects (BTO 민간투자사업 해지시지급금 매수청구권 가치에 관한 연구)

  • Shin, Sung-Hwan
    • Korean Journal of Construction Engineering and Management
    • /
    • 제12권3호
    • /
    • pp.121-130
    • /
    • 2011
  • Real option values of early termination payment for selected BTO PPI projects are studied using binomial models. Two cases of early termination payments are considered; an option with the condition of private participants' default, and an option without the condition. Values vary depending upon parameter values such as revenues, costs, discount rates, debt ratio, and volatility of revenues. For selected projects, the option values without the default condition are estimated as 1%~7% of total project costs, whereas the option values with the default condition are estimated as 0%~1.89% of total project cost. When actual revenues differ from the forecasted revenues, apparently the option values deviate from the values based upon the forecasted revenues. When actual revenues fall short of the forecasted revenues, the option values increase by a large amount whereas the option values decrease by a small amount in the opposite case. This implies that the option values can be quite bigger than the values based upon the forecasted revenue especially when the revenue forecast uncertainty is large. This study is expected to play an important role in improving the early termination payment option policy of the government in PPI projects in Korea.

Performance and Design of Cable Termination for 154kV Class (154kV 케이블 콘넥터의 설계와 특성 평가 연구)

  • Cho, Han-Goo;Kim, Kyang-Young;Lee, Cheol-Ho;Lee, Yong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

Operation-level Early Termination Algorithm for Inter-predictions in HEVC

  • Rhee, Chae Eun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권4호
    • /
    • pp.235-242
    • /
    • 2016
  • The emerging High-Efficiency Video Coding (HEVC) standard attempts to improve coding efficiency by a factor of two over H.264/Advanced Video Coding (AVC) at the expense of an increase in computational complexity. Mode decision with motion estimation (ME) is still one of the most time-consuming computations in HEVC, as it is with H.264/AVC. Thus, fast mode decisions are not only an important issue to be researched, but also an urgent one. Several schemes for fast mode decisions have been presented in reference software and in other studies. However, the conventional hierarchical mode decision can be useless when block-level parallelism is exploited. This paper proposes operation-level exploration that offers more chances for early termination. An early termination condition is checked between integer and fractional MEs and between the parts of one partition type. The fast decision points of the proposed algorithm do not overlap those in previous works. Thus, the proposed algorithms are easily used with other fast algorithms, and consequently, independent speed-up is possible.

Development of Ground System to Improve Link Reliability of Flight Termination System for Guided Missiles (유도무기 비행종단시스템의 통신 신뢰도 향상을 위한 지상국 시스템 개발)

  • Yoon, Dongsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제24권7호
    • /
    • pp.891-897
    • /
    • 2020
  • A flight termination system, which consists of ground and vehicle systems, forcibly terminates flight if it is deemed dangerous. In order to accomplish this, the system should maintain the link reliability above a certain level throughout the whole flight. However, the national proving ground for guided missiles could not fully meet that condition because of the gradually improving performance criteria. In this paper, we have analyzed the link budget for the flight termination system. Furthermore, we have designed and developed an emergency destruction command transmitter system, which is a ground system of the flight termination system, to provide the necessary link margin. Afterwards, we measured the received signal strength at the vehicle system and compared it with that of the existing transmitter system. We hereby confirmed that the link reliability of the flight termination system improved.

Thermal Characteristics Analysis by Ambient and Operating Temperature according to the Kinds of Terminations in Underground Power Cable Systems (지중송전케이블 종단접속함 종류에 따른 외기 및 운전온도에 의한 열특성 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won;Lee, Bang-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제64권8호
    • /
    • pp.1154-1160
    • /
    • 2015
  • This paper describes the thermal characteristics of underground power cable system terminations according to the change of ambient temperature as well as operating temperature. Recently, the failure has been gradually increasing in outdoor termination during winter season because the power demand was increased by electricity heating system. The power demand and outdoor temperature is difference between day time and night time. The temperature difference has an influence on conductor extension and shrinkage due to conductor force as well as thermal mechanical characteristics. These phenomena have daily repeated during heating and cooling period of conductors. In these cases, the insulation of outdoor terminations might be degraded by the reduced interface pressure surrounding stress relief cone. Therefore, in this paper, the thermal characteristics are variously analysed by simulation considering power demand and ambient temperature condition during winter season at epoxy type termination as well as slip-on type termination

A Termination Analyzer Including Execution Semantics of Active Rules (능동 규칙의 실행의미를 반영한 종료 분석기)

  • Sin, Ye-Ho;Hwang, Jeong-Hui;Ryu, Geun-Ho
    • The KIPS Transactions:PartD
    • /
    • 제8D권5호
    • /
    • pp.513-522
    • /
    • 2001
  • Active database execute an action of active rule defined in advance which is triggered automatically, whenever an event with the matching event specifications occurs, its condition is evaluated. Because these rules may in turn trigger other rules, the set of rules may be triggered each other indefinitely, Therefore, we propose a termination analysis method to guarantee termination. This proposed method considers composite event as well as rule execution time. Above all, the method not only uses deactivation graph combined to trigger graph for exact analysis, but also improves the complexity of analysis. Also the proposed method enhances accuracy of analysis result.

  • PDF

The Effect of Image Rejection Filter on Flatness of Microwave Terrestrial Receiver

  • Han, Sok-Kyun;Park, Byung-Ha
    • Journal of electromagnetic engineering and science
    • /
    • 제3권2호
    • /
    • pp.86-90
    • /
    • 2003
  • A flat conversion loss in microwave mixer is hard to achieve if integrating with an image rejection filter(IRF). This is due to the change of termination condition with respect to the LO and IF frequency at RF port where the filter has 50 ohm termination property only in the RF band. This paper describes a flatness maintenance in the down mixer concerning a diode matching condition as well as an electrical length of embedding line at RF port. The implemented single balance diode mixer is suitable for a 23 ㎓ European Terrestrial Radio. RF, LO and fixed IF frequency chosen in this paper are 21.2∼22.4 ㎓, 22.4∼23.6 ㎓ and 1.2 ㎓, respectively. The measured results show a conversion loss of 8.5 ㏈, flatness of 1.2 ㏈ p-p, input P1㏈ of 7㏈m, IIP3 of 15.42 ㏈m with nominal LO power level of 10㏈m. The return loss of RF and LO port are less than - 15 ㏈ and - 12 ㏈, respectively and IF port is less than - 6 ㏈. LO/RF and LO/IF isolation are 18 ㏈ and 50 ㏈, respectively. This approach would be a helpful reference for designing up/down converter possessing a filtering element.